Electrode Finder
6.0910.120
Conductivity measuring cell c = 0.9 cm-1Conductivity measuring cell with cell constant c = 0.9 cm-1, without integrated temperature sensor. This sensor is suitable for measurements of medium conductivities (1 uS/cm to 100 mS/cm), e.g., in: drinking water; surface water; wastewater; This sensor is suitable for automated applications (includes an SGJ 14/15).
6.0912.110
Conductivity measuring cell c = 0.8 cm-1 with Pt1000 (fixed cable)Conductivity measuring cell with cell constant c = 0.8 cm-1, with integrated Pt1000 temperature sensor and with fixed cable (4 x B (4 mm)). Thanks to the robust/break-proof plastic shaft made of polypropylene and an impact protection, this sensor is mechanically very resistant. This sensor is suitable for measurements of medium conductivities (1 uS/cm to 100 mS/cm), e.g., in: drinking water; surface water; wastewater; The sensor can be connected to an 856 Conductivity Module with the adapter box (6.2103.160).
6.0913.130
Measuring vessel cover for stability measuring instrumentsWith built-in conductometric measuring cell.
6.0914.040
Conductivity measuring cell c = 0.1 cm-1 with Pt1000 (fixed cable)Conductivity measuring cell made of stainless steel with cell constant c = 0.1 cm-1, with integrated Pt1000 temperature sensor and with fixed cable (4 x B (4 mm)).This sensor is suitable for measurements of low conductivities (0 uS/cm to 300 uS/cm), e.g., in deion. water or for measurements in accordance with USP <645>.The sensor can be connected to an 856 Conductivity Module with the adapter box (6.2103.160).
6.0915.100
5-ring conductivity measuring cell c = 0.7 cm-1 with Pt1000 (fixed cable)5-ring conductivity measuring cell with cell constant c = 0.7 cm-1 (guide value), with integrated Pt1000 temperature sensor and with fixed cable (1.2 m) for connecting to an 856 Conductivity Module.This sensor is suitable for measurements of medium conductivities (5 µS/cm to 20 mS/cm), e.g., in:drinking water; surface water; wastewater;
6.0915.130
5-ring conductivity measuring cell c = 1.0 cm-1 with Pt1000 (fixed cable)5-ring conductivity measuring cell with cell constant c = 1.0 cm-1 (guide value), with integrated Pt1000 temperature sensor and with fixed cable (1.2 m) for connecting to an 856 Conductivity Module in combination with a sample changer.This sensor is suitable for automated measurements of medium conductivities (5 µS/cm to 100 mS/cm), e.g., in:drinking water; surface water; wastewater;
6.0916.040
Conductivity measuring cell c = 0.1 cm-1 with Pt1000 (fixed cable)Conductivity measuring cell made of stainless steel with cell constant c = 0.1 cm-1 (guide value), with integrated Pt1000 temperature sensor and fixed cable (1.2 m) for connecting to an 856 Conductivity Module.This sensor is suitable for measurements of low conductivities (0 µS/cm to 300 uS/cm) in e.g., deion. water or for measurements in accordance with USP <645>.
6.0917.080
Conductivity measuring cell c = 0.5 cm-1 with Pt1000 (fixed cable)4-wire conductivity measuring cell with cell constant c = 0.5 cm-1 (guide value), with integrated Pt1000 temperature sensor and fixed cable for connecting to 912/914 Meters.Thanks to the robust/break-proof plastic shaft made of PEEK, this sensor is mechanically very resistant. The sensor is suitable for measurements of medium conductivities (15 µS/cm to 250 mS/cm), e.g., in:drinking water; surface water; wastewater;
6.0918.040
Conductivity measuring cell c = 0.1 cm-1 with Pt1000 (fixed cable)Conductivity measuring cell made of stainless steel with cell constant c = 0.1 cm-1 (guide value), with integrated Pt1000 temperature sensor and fixed cable for connecting to 912/914 Meters.This sensor is suitable for measurements of low conductivities (0 µS/cm to 300 uS/cm) in, e.g. deion. water.
6.0919.140
Conductivity measuring cell c = 1.6 cm-1 with Pt1000 (fixed cable)3-ring conductivity measuring cell with cell constant c = 1.6 cm-1, with integrated Pt1000 temperature sensor and fixed cable for connecting to 912/914 Meters.This sensor is suitable for measurements of high conductivities (0.1 to 1000 mS/cm), e.g., in:sea water; flush water; physiological solutions;
6.0920.100
5-ring conductivity measuring cell c = 0.7 cm-1 with Pt1000 (fixed cable 2 m)5-ring conductivity measuring cell with cell constant c = 0.7 cm-1 (guide value), with integrated Pt1000 temperature sensor and fixed cable (2.0 m) for connecting to an 856 Conductivity Module in combination with a sample changer.This sensor is suitable for automated measurements of medium conductivities (5 µS/cm to 20 mS/cm), e.g., in:drinking water; surface water; wastewater;
6.0920.130
5-ring conductivity measuring cell c = 1.0 cm-1 with Pt1000 (fixed cable 2 m)5-ring conductivity measuring cell with cell constant c = 1.0 cm-1 (guide value), with integrated Pt1000 temperature sensor and fixed cable (2.0 m) for connecting to an 856 Conductivity Module in combination with a sample changer. This sensor is suitable for automated measurements of medium conductivities (5 µS/cm to 100 mS/cm), e.g., in:drinking water; surface water; wastewater;
6.09331.110
ProTrode 200 sensorThe ProTrode 200 sensor is a combined pH sensor with integrated Pt1000 designed to perform inline pH measurements biotechnology and pharmaceutical processes. This non-pressurized sensor has a measuring range from 0 – 12 pH and because of its unique sleeve diaphragm design, enables very accurate pH measurements with low response time’s independent of the process flow.The included Ag guard prevents silver fouling into the process and diaphragm blockage in processes containing sulfide or proteins.
6.09331.210
ProTrode 300 sensorThe ProTrode 300 sensor is a combined pH sensor with integrated Pt1000 designed to perform inline pH measurements in biotechnology and pharmaceutical processes. The pressurized sensor has a measuring range from 0 – 12 and ceramic pin diaphragm design, which enables accurate pH measurements, with good response times.The included Ag scavenger prevents silver fouling into the process and diaphragm blockage in processes containing sulfide or proteins.
6.09331.310
ProTrode 250 sensorThe ProTrode 250 sensor is a combined pH sensor with integrated Pt1000 designed to perform inline pH measurements in chemical processes which require demanding sensor specifications. The pressurized inline pH sensor has a measuring range from 0 – 14 pH and a unique sleeve diaphragm design, which enables very accurate pH measurement, with low response time’s independent of process flow.
6.09331.410
Protrode 350 sensorThe ProTrode 350 sensor is a combined pH sensor with integrated Pt1000 designed to perform inline pH measurements in chemical processes which require demanding sensor specifications. The pressurized inline pH sensor has a measuring range from 0 – 14 pH and a ceramic pin diaphragm design, which enables very accurate pH measurement, with low response time’s independent of process flow.
6.09395.014
Glassy carbon electrode tipElectrode tip made of glassy carbon (GC) for Autolab RDE, electrode disk diameter 3 mm, M4 thread connection. Temperature range: 0 - 40 °C.
6.09395.024
Platinum electrode tipElectrode tip made of platinum (Pt) for Autolab RDE, 3 mm electrode disc diameter, M4 thread connection. Temperature range: 0 - 40°C.
6.09395.034
Gold electrode tipElectrode tip made of gold (Au) for Autolab RDE, electrode disc diameter 3 mm, M4 thread connection. Temperature range: 0 - 40°C.
6.09395.044
Silver electrode tipElectrode tip made of silver (Ag) for Autolab RDE, 3 mm electrode disc diameter, M4 thread connection. Temperature range: 0 - 40°C.
6.1110.010
Pt1000 temperature sensor for 909 UV DigesterPt1000 temperature sensor (class B) made of glass with fixed cable (0.5 m) for connecting to a 909 UV Digester.
6.1110.100
Pt1000 temperature sensor (installation length 12.5 cm)Pt1000 temperature sensor (class B) made of glass.This PT1000 temperature sensor is also available under the article number 6.1110.110 with an installation length of 17.8 cm.
6.1110.110
Pt1000 temperature sensor (installation length 17.8 cm)Pt1000 temperature sensor (class B) made of glass for sample changers.
6.1110.120
Pt1000 temperature sensor for CVS (installation length 9 cm)Pt1000 temperature sensor (class B) for Professional CVS Instruments.
6.1111.010
Pt100 temperature sensor for stability measuring devicesPt100 temperature sensor (length 17.5 cm) with fixed cable and mini-DIN-plug. This glass-free temperature sensor is well suited for use with a 711 Liquino and instruments for stability measurement (743 Rancimat, 763 PVC Thermomat, 892 Professional Rancimat, or 895 Professional PVC Thermomat).
6.1111.020
Pt100 temperature sensor for stability measuring devicesPt100 temperature sensor (length 30.0 cm) with fixed cable and mini-DIN-plug. This glass-free temperature sensor is well suited for use with instruments for stability measurement (873 Biodiesel Rancimat and 893 Professional Biodiesel Rancimat).
6.1113.000
Sensor for 849 Level ControlSensor for 849 Level Control
6.1113.100
Level sensor MF for 10 L canisterSensor for Level Control MF
6.1114.010
Pt1000 temperature sensor made of stainless steelPt1000 temperature sensor (class B) with fixed cable (1.2 m), with a needle made of stainless steel and a PEEK shaft. This glass-free temperature sensor is well suited for measurements:in semisolid materials (e.g., cheese, meat); in non-oxidizing materials at pH 1 to 13;
6.1115.000
OptrodeOptical sensor for photometric titrations offering 8 different wavelengths. The wavelength can be switched using the software (tiamo 2.5 or higher) or with a magnet. The glass shaft is completely solvent-resistant and easy to clean. For example, this space-saving sensor is suitable for:Non-aqueous titrations in accordance with USP or EP; Determinations of carboxyl end groups; TAN/TBN in accordance with ASTM D974; Sulfate determination; Fe, Al, Ca in cement; Water hardness; Chondroitin sulfate in accordance with USP; The sensor is not suitable for determinations of concentrations via measurement of color intensity (colorimetry).
6.1116.000
O2 LumitrodeThe optical sensor for measuring dissolved oxygen (DO) can be used with a 913 pH/DO meter or with a 914 pH/DO conductometer. The measuring principle of the sensor is based on luminescence quenching. The space-saving and maintenance-free sensor is suitable for DO measurement, for example in: Water quality control; Wastewater industry; Beverage production; Fish farming; This sensor is supplied with a calibration vessel. Where necessary, it is easy to replace the measurement cap (O2 cap) that contains the oxygen-intensive luminophore.
6.1204.130
Silver Electrode TipMetal electrode tip, silver (Ag). Electrode disk diameter 2 mm. M3 thread. Temperature range: 0 ... 40 °C.
6.1204.140
Gold Electrode TipMetal electrode tip, gold (Au). Electrode disk diameter 2 mm. M3 thread. Temperature range: 0 ... 40 °C.
6.1204.150
Lateral Gold Electrode TipMetal electrode tip, gold (Au), with lateral electrode surface. Electrode disk diameter 3 mm. M3 thread. Temperature range: 0 ... 40 °C.
6.1204.170
3 mm platinum electrode tip for CVSMetal electrode tip made of platinum (Pt), diameter of electrode disk 3 mm, polished surface, M3 thread connection. Temperature range: 0 - 40 °C.
6.1204.180
Ultra Trace electrode tipCarbon electrode tip from Ultra Trace graphite. Electrode disk diameter 2 mm. M3 thread connection. Temperature range: 0 - 40 °C.
6.1204.190
1 mm platinum electrode tip for CVSMetal electrode tip made of platinum (Pt), diameter of electrode disk 1 mm ±0.02 mm, polished surface, shaft made of glass, M3 thread connection. Concentricity error: < 0.2 mm. Temperature range: 0 - 50 °C.
6.1204.210
Driving axle for rotating disk electrode (RDE)Driving axle for rotating disk electrode (RDE) with titanium axle for VA measuring stands, M3 thread.
6.1204.220
Driving axle for rotating disk electrode (RDE) with mercury contactDriving axle for rotating disk electrode (RDE) with titanium axle and mercury contact for VA measuring stands, M3 thread.
6.1204.510
Driving axle for rotating disk electrode (RDE)Driving axle for rotating disk electrode (RDE) with titanium axle for Professional VA/CVS instruments, M3 thread.
6.1204.520
Driving axle for rotating disk electrode (RDE) with mercury contactDriving axle for rotating disk electrode (RDE) with titanium axle and mercury contact for Professional VA/CVS instruments, M3 thread.
6.1204.600
Glassy carbon electrode tip, shaft made of glass.Carbon electrode tip made of Glassy-Carbon (GC). Diameter of electrode disk 2 mm ±0.1 mm, polished surface, shaft made of glass, M3 thread connection, concentricity deviation: <0.25 mm. Temperature range: 0 - 50°C.
6.1204.610
2 mm platinum electrode tip for CVSMetal electrode tip made of platinum (Pt), diameter of electrode disk 2 mm ±0.05 mm, polished surface, shaft made of glass, M3 thread connection. Concentricity error: < 0.3 mm. Temperature range: 0 - 50 °C.
6.1226.030
Mercury drop capillary (non-silanized) for MMENon-silanized mercury drop capillary (10 pieces)
6.1226.050
Mercury drop capillary (silanized) for MMESilanized mercury drop capillary (10 pieces)
6.1240.000
Electrolyte vessel / diameter 3 mmWith PTFE capillary and ceramic diaphragm (3 mm)
6.1240.020
Electrolyte vessel, diameter 1 mmWith ceramic diaphragm (D type).
6.1241.020
Electrode holderElectrode holder for VA auxiliary electrodes with lock bolt. For use with glassy carbon rod (6.1247.000) or platinum pin (6.1247.010).