tiamo er en kontroll- og databaseprogramvare for titratorer, doseringsenheter og prøvevekslere som tillater fullstendig laboratorieautomatisering, og derfor står navnet tiamo for «titrering og mer» – tiamo kan langt mer enn bare titrere.

Kompatibilitet av tiamo-versjoner med Windows-operativsystemer:

64-bit operating systems are supported for tiamo 2.3 and higher.
  tiamo 1.0–1.3
tiamo 2.0–2.1
tiamo 2.2–2.3
tiamo 2.4
tiamo 2.5
tiamo 3.0
Windows 2000
Yes Yes Yes


Windows XP (SP1, SP2, SP3) 
Yes Yes
Yes
Yes Yes
Windows Vista

Yes Yes Yes Yes – 
Windows 7

Yes Yes
Yes
Windows 8


Yes
Yes
Windows 8.1



Yes

Windows 10




Yes
Yes
Windows 11
Windows Server 2003



Yes Yes

Windows Server 2008



Yes Yes

Windows Server 2008 R2



Yes Yes

Windows Server 2012



Yes Yes

Windows Server 2012 R2




Yes
Yes
Windows Server 2016




Yes Yes
Windows Server 2019 





Yes
Windows Server 2022
– 

Utfør aldri en oppgradering fra tiamo 2.x til tiamo 3.0 uten en gyldig lisenskode for tiamo 3.0! Uten gyldig lisenskode får du kun en demoversjon som utløper etter 30 dager. En nedgradering fra tiamo 3.0 tilbake til tiamo 2.X er IKKE mulig!

For å få en gyldig tiamo 3.0 lisenskode, vennligst kontakt din lokale Metrohm-distributør.

Det samme gjelder for en oppgradering fra 1.x til tiamo 2.x, utfør aldri en oppgradering fra tiamo 1.x til tiamo 2.x uten gyldig lisenskode for tiamo 2.x!

En direkte oppgradering fra tiamo 1.x til tiamo 3.0 er ikke mulig, vennligst kontakt din lokale Metrohm-distributør.

Hvis du installerer oppdateringen for kinesisk eller tradisjonell kinesisk språk, sørg for at den respektive tegnstøtten er aktivert i språkinnstillingene på din personlige datamaskin.

For å installere en språkoppdatering, pakk ut og kjør EXE-filen fra den nedlastede og komprimerte ZIP-filen. Installasjonen vil da bli utført automatisk.

Download the required software version as well as the respective language packs and documents below.

Download the tiamo 3.0 version with the newest upgrades here:

Download tiamo 3.0

The following additional dialog languages can be downloaded for tiamo 3.0:

Simplified Chinese

Traditional Chinese

Czech

Italian

Japanese

Polish

Portuguese

Russian

Slovak

French

Spanish

Downloads

8.101.8080 Release Notes tiamo 3.0 (English)

Download the tiamo 2.5 version with the newest upgrades here:

Download tiamo 2.5

Patch for tiamo 2.5

The main improvement with this patch is:

  1. Configuration program part
  2. In tiamo 2.5 light, if the Enforce login with user name check box was active in the Security settings under Login policies/Password policies and then the [OK] button was pressed, the program crashed.

The following additional dialog languages can be downloaded for tiamo 2.5:

Simplified Chinese

Traditional Chinese

Czech

Italian

Japanese

Polish

Portuguese

Russian

Slovak

French

Spanish

Downloads

8.101.8072 Release Notes tiamo 2.5

8.101.8075 Release Notes tiamo 2.5 Patch 1                 

Download the tiamo 2.4 version with the newest upgrades here:

Download tiamo 2.4

The following additional dialog languages can be downloaded for tiamo 2.4:

Chinese

Traditional Chinese

French

Italian

Japanese

Polish

Portuguese

Russian

Slovak

Spanish

Downloads

8.101.8055EN Release Notes tiamo 2.4

Download the tiamo 2.3 version with the newest upgrades here:

Download tiamo 2.3

Patch 1 for tiamo 2.3

The main improvement with this patch is:

Program part Configurationthe limitation to two devices applies only for Metrohm devices (Titrino, Titrando, etc.); that means that balances and other generic (i.e. non-Metrohm) devices can be included without limitation.

The following additional dialog languages can be downloaded for tiamo 2.3:

Chinese

Traditional Chinese

French

Italian

Japanese

Polish

Portuguese

Russian

Slovak

Spanish

Downloads

8.101.8039EN Release Notes tiamo 2.3

8.101.8047EN Release Notes tiamo 2.3 Patch 1

8.101.8040EN CONF tiamo 2.3

8.101.8042EN FDA Certificate tiamo 2.3

Download the tiamo 2.2 version with the newest upgrades here:

Download tiamo 2.2

Patch 1 for tiamo 2.2

This patch eliminates the following bugs:

  1. In the dialog window Reprocessing on the tab Statistics, the table is not being shown.
  2. If the monitoring of the titer validity, the common variable, the global variable or the calibration data has expired, it is not possible to newly determine the titer, the common variable or the global variable via the CALC command ("Save result as...") or to carry out a calibration.
  3. The program crashes when running MET determinations with Titrinos.
  4. If the beaker test is enabled and the action "Stop determination and series" is selected in the MOVE command for the beaker test, then the error track will not being run through when a beaker is missing

The following additional dialog languages can be downloaded for tiamo 2.2:

Chinese

Traditional Chinese

French

Italian

Japanese

Polish

Portuguese

Slovak

Spanish

Russian

Downloads

8.101.8027EN Release Notes tiamo 2.2

8.101.8036EN Release Notes tiamo 2.2 Patch 1

Download the tiamo 2.1 version with the newest upgrades here:

Download tiamo 2.1

The following additional dialog languages can be downloaded for tiamo 2.1:

Chinese

Traditional Chinese

French

Italian

Japanese

Portuguese

Slovak

Spanish

Russian

Downloads

8.101.8017EN Release Notes tiamo 2.1

Download the tiamo 2.0 version with the newest upgrades here:

Download tiamo 2.0

Patch 1 for tiamo 2.0

This patch eliminates the following bugs:

  1. when doing a SET, KFT or KFC with deactivated 'Automatic conditioning' a start drift of 0.0 was taken
  2. when doing an upgrade from tiamo 1.3 to 2.0 the BackupServer.exe wasn't replaced
  3. the remote interface for the devices 778, 789, 888 and 890 didn't work or wasn't available, at all
  4. the evaluation with window didn't work with Titrinos
  5. when switching of the reference temperature for MEAS Cond an exception occured

The following additional dialog languages can be downloaded for tiamo 2.0:

Chinese

Traditional Chinese

French

Italian

Japanese

Polish

Portuguese

Russian

Slovak

Downloads

8.101.8009EN Release Notes tiamo 2.0

Download the tiamo 1.3 version with the newest upgrades here:

Download tiamo 1.3

The following additional dialog languages can be downloaded for tiamo 1.3:

Chinese

Traditional Chinese

Italian

Polish

Portuguese

Russian

Slovak

Downloads

8.101.1023EN Release Notes tiamo 1.3                 

Download the tiamo 1.2.1 version with the newest upgrades here:

Download tiamo 1.2.1

The following additional dialog languages can be downloaded for tiamo 1.2.1:

Chinese

Traditional Chinese

Italian

Japanese

Polish

Russian

Download the tiamo 1.2 version with the newest upgrades here:

Download tiamo 1.2

Patch 1 for tiamo 1.2

Patch 2 for tiamo 1.2

Patch 1 eliminates the following bug in tiamo 1.2:

When a method is started, which utilisizes the diff-measuring input, then misleadingly the following message appears:

"Wrong measuring input (011-122).

"The text is for example like:

"The non-intelligent sensor 'pH Electrode' demanded by the command 'MEAS pH' can't be connected to the measuring input 3 at device ''702_1'. Choose a different sensor or a different measuring input."

Patch 2 eliminates the following bugs in tiamo 1.2:

While manual actions in one device (manual control or while method run) it may happen, that the reservation of the device isn't enabled in a correct way.

Additionally, this Patch 2 includes Patch 1 (cummulative Patch).

Download the tiamo 1.1 version with the newest upgrades here:

Download tiamo 1.1

Progress Bar Patch

Timer Patch

Download the tiamo 1.0 version with the newest upgrades here:

Download tiamo 1.0