Product families
Product families (70)Product models
Product models (714)Applications
Applications (2250)Trainings & webinars by experts
Events (3)Electrodes
Electrodes (509)Columns
Columns (155)Accessories
Accessories (2248)Software
Software (269)Manuals & brochures
Documents (2595)Other content
Items (121)Inspiring industry insights
Insights (176)Unmatched support & service
Support & service (81)Trainings & webinars by experts
Webinars (69)News
News (54)MVA-22
884 Professional VA fully automated for VAAutomated analysis system for high-performance, flexible trace determinations with voltammetry and polarography with the Multi-Mode Electrode pro or the scTRACE Gold. Comprising 884 Professional VA for MME, 919 IC Autosampler plus for VA, two 800 Dosinos, 843 Pump Station, measuring head for rotating disk electrodes, and extensive accessories. For sample series of up to 28 samples.Determinations with rotating disc electrodes can also be performed with the MVA-22, e.g. determinations of organic additives in electroplating baths with "Cyclic Voltammetric Stripping" (CVS), "Cyclic Pulse Voltammetric Stripping" (CPVS), and chronopotentiometry (CP).The viva software is required for control, data acquisition, and evaluation. PC, electrode set, and viva license need to be ordered separately.
MVA-23
884 Professional VA fully automated for CVS and large sample seriesAutomated analysis system for the high-performance, flexible determination of organic additives in electroplating baths using CVS ("Cyclic Voltammetric Stripping"), CPVS ("Cyclic Pulse Voltammetric Stripping"), and chronopotentiometry (CP), or voltammetric heavy metal determinations with rotating disk electrodes. Comprising 884 Professional VA for CVS, 858 Professional Sample Processor, four 800 Dosinos, 843 Pump Station, measuring head for rotating disk electrodes. and extensive accessories. For sample series of up to 56 samples.The MVA-23 can also be used to perform voltammetric determinations with the Multi-Mode Electrode or the scTRACE Gold.The viva software is required for control, data acquisition, and evaluation. PC, electrode set, and viva license need to be ordered separately.
MVA-24
884 Professional VA fully automated for CVS with Dosino for sample transferAutomated analysis system for the high-performance, flexible determination of organic additives in electroplating baths using CVS ("Cyclic Voltammetric Stripping"), CPVS ("Cyclic Pulse Voltammetric Stripping"), and CP ("Chronopotentiometry"). Comprising 884 Professional VA for CVS, 858 Professional Sample Processor with Dosino for sample transfer, 4x additional 800 Dosinos for auxiliary solutions, 843 Pump Station, measuring head for rotating disk electrodes, and extensive accessories. For sample series of up to 112 samples.The viva software is required for control, data collection, and evaluation. PC, electrode set, and viva license need to be ordered separately.
MVA-25
884 Professional VA fully automated for the determination of antioxidantsAutomated analysis system for the voltammetric determination of antioxidants in lubricants, including automatic sample preparation on the sample changer. Comprising 884 Professional VA, 858 Professional Sample Processor for antioxidants, 2x 800 Dosinos, 843 Pump Station, measuring head for rotating disk electrodes, and extensive accessories. For sample series of up to 24 samples.The viva software is required for control, data collection, and evaluation. PC, electrode set, and viva license need to be ordered separately.
ORPKIT
Kit for ORP measurementsPortable oxidation reduction potential (ORP) reader kit. Suitable for in situ measurements with small sample volumes. This system uses disposable ORP sensors and has the ability to store data internally.
ProfIC 1 - AnCat
"ProfIC 1 – AnCat" – Professional IC System for automated ion chromatographyThe very compact Professional IC system with conductivity detection enables the fully automatic determination of anions and cations. With "ProfIC 1 – AnCat", anions and cations can be determined not only in parallel but also in time-saving fashion completely independently of one another. Both of the systems integrated in "ProfIC 1 – AnCat" use the same 858 Professional Sample Processor with pump that is subjected to intelligent management by the MagIC Net™ software. Schematic diagram
ProfIC 1 - Anion
"ProfIC 1 – Anion" – Professional IC System for automated ion chromatographyThe Professional IC system with sequential suppression and conductivity detection enables the fully automatic determination of anions. "ProfIC 1" enables the safe management of all routine tasks in ion chromatography. It is simple to use and exceptionally reliable. Schematic diagram
ProfIC 1 - Cation
"ProfIC 1 – Cation" – Professional IC System for automated ion chromatographyProfessional IC system with conductivity detection enables the fully automatic determination of cations and anions (non-suppressed). "ProfIC 1" enables the safe management of all routine tasks in ion chromatography. It is simple to use and exceptionally reliable. Schematic diagram
ProfIC 2 - AnCat
"ProfIC 2 – AnCat" – Professional IC System with Inline UltrafiltrationThe very compact Professional IC system with Metrohm Inline Ultrafiltration and conductivity detection enables the fully automatic determination of anions and cations. With "ProfIC 2 – AnCat", anions and cations can be determined not only in parallel but also in time-saving fashion completely independently of one another. The two systems integrated in "ProfIC 2 – AnCat" use the same 858 Professional Sample Processor – Pump that is subjected to intelligent management by the MagIC Net™ software. Schematic diagram
ProfIC 2 - Anion
"ProfIC 2 – Anion" – Professional IC System with Inline UltrafiltrationThe Professional IC system with Metrohm Inline Ultrafiltration and conductivity detection enables the fully automatic determination of anions. "ProfIC 2" enables the safe management of all routine tasks in ion chromatography. It is simple to use and exceptionally reliable. Schematic diagram
- AN-H-016AN-H-016Determination of acetic, phosphoric, and nitric acid mixtures
Determination of mixtures of phosphoric, nitric, and acetic acids used in etching aluminum in the manufacture of semiconductor devices.
- AN-H-017AN-H-017Determination of bromide and chloride in photographic developer solutions
Determination of bromide and chloride in photographic developer solutions.
- AN-H-018AN-H-018Determination of chloride in drilling fluids
Determination of chloride in oil well drilling fluids.
- AN-H-019AN-H-019Determination of chlorine in household bleaches
Determination of chlorine in household bleaches.
- AN-H-020AN-H-020Determination of chromium in leather waste solutions
Determination of chromium in leather waste solutions in the range between 1000 and 30,000 ppm.
- AN-H-021AN-H-021Determination of free acid in copper refining solutions
Determination of free acid in copper refining solutions.
- AN-H-022AN-H-022Determination of moisture in lubricating oils with TEOF
Determination of moisture in lubricating oils with TEOF (triethyl orthoformate).
- AN-H-023AN-H-023Determination of nickel by dimethylglyoxime titration
Determination of nickel in the absence of cobalt and other interferences.
- AN-H-024AN-H-024Determination of tar acids (phenolics) in tar products
Determination of tar acids in coal tar products. This procedure may also be applied to the determination of a range of weakly acidic organic compounds such as carboxylic acids, hydroxy acids, phenols, phenolic acids, keto-enols, imides, and aromatic nitro compounds.11 Vaughan, G. A. Thermometric and Enthalpimetric Titrimetry. Van Nostrand Reinhold Co. Ltd (1973)
- AN-H-025AN-H-025Determination of moisture in lubricating oils by DMP
Determination of water in automotive lubricating oils.
6.1432.320
Sample beaker, clear glass, 250 mL, 1 pieceSample beaker, clear glass, 250 mL, suitable for sample racks: 6.2041.310, 6.2041.400, 6.2041.430, 6.2041.510, 6.2041.820, 6.2068.020 and 6.2068.030, 1 piece
6.1432.323
Sample beaker, amber glass, 250 mL, 1 pieceSample beaker, amber glass, 250 mL, suitable for sample racks: 6.2041.310, 6.2041.400, 6.2041.430, 6.2041.510, 6.2041.820, 6.2068.020, and 6.2068.030, 1 piece
6.1437.000
SGJ stopper SGJ 146.1438.000
Gas outlet tube SGJ 146.1439.010
KF addition and aspiration tubeKF addition and aspiration tube for coulometer cell, incl. M8 screw connector 6.1811.010.
6.1439.020
Gas inlet tube with fritGas inlet tube for coulometric KF cell
6.1440.010
Gas inlet and overflow tube with valveFor bubbling or covering of the sample by inert gas.
6.1446.000
SGJ stopper / B-14/(15)6.1446.010
StopperUsed with Sample Changers
6.1446.030
Ball stopper / B-14/(15)For the movable holding of buret tips in titration vessels