Product families
Product families (70)Product models
Product models (714)Applications
Applications (2250)Trainings & webinars by experts
Events (3)Electrodes
Electrodes (509)Columns
Columns (155)Accessories
Accessories (2248)Software
Software (269)Manuals & brochures
Documents (2595)Other content
Items (121)Inspiring industry insights
Insights (176)Unmatched support & service
Support & service (81)Trainings & webinars by experts
Webinars (69)News
News (54)2.928.0230
NIRS XDS Process Analyzer – SingleFiber 9 ChannelsThe NIRS XDS Process Analyzer – SingleFiber provides the next generation of process analyzers for real-time analysis in the pharmaceutical and chemical industries. Non-destructive, accurate measurements of clear liquids are performed directly in the process line or in a reaction vessel. Up to 9 probes and/or flow-cells can be connected to the analyzer. All 9 channels can be configured independently from each other in the software. Single Fiber optics allows the 9 measuring points to be up to 100 meter away from the XDS NIR process analyzer.
2.928.0310
NIRS XDS Process Analyzer – DirectLight/NonContact-Single pointBased on NIR XDS technology, the NIRS XDS Process Analyzer – DirectLight/NonContact is numbered among the next generation of non-contact process analyzers for real-time analysis above a conveyor belt, web or sheet. Non-destructive, accurate measurements are performed of practically any moving solid product.
2.928.1110
NIRS Analyzer PRO – ContactReflectionThe NIRS Analyzer Pro is a single point process analysis system based on high resolution diode array technology. It provides non-destructive analysis of granules, powders through a glass window directly in the process line without bypass – a true in-line system.
2.928.1120
NIRS Analyzer PRO – FiberSystemThe NIRS Analyzer Pro is a single point process analysis system based on high resolution diode array technology. It provides non-destructive analysis of liquids, granules, powders, slurries or opalescent substances by using fiber optics microbundles and contact probes for reflectance, transflectance and transmission measurements.
2.928.1130
NIRS Analyzer PRO – DirectLight/NonContactThe NIRS Analyzer Pro is a single point process analysis system based on high resolution diode array technology. It provides non-destructive analysis of solids like granules and powders. This system is typically mounted above a conveyor belt in order to analyze products passing by.
2.930.1100
930 Compact IC FlexThe 930 Compact IC Flex is the intelligent Compact IC instrument without suppression. The instrument can be used with any separation and detection methods.Typical areas of application:Anion or cation determinations without suppression with conductivity detection; Simple applications with UV/VIS or amperometric detection;
2.930.1160
930 Compact IC Flex DegThe 930 Compact IC Flex Deg is the intelligent Compact IC instrument without suppression with built-in degasser. The instrument can be used with any separation and detection methods.Typical areas of application:Anion or cation determinations without suppression with conductivity detection; Simple applications with UV/VIS or amperometric detection;
2.930.1200
930 Compact IC Flex ChSThe 930 Compact IC Flex ChS is the intelligent Compact IC instrument with chemical suppression. An 800 Dosino can be used for the regeneration of the suppressor. The instrument can be used with any separation and detection methods.Typical areas of application:Anion determinations with chemical suppression and conductivity detection; Organic acids with ion-exclusion chromatography and inverse suppression;
2.930.1260
930 Compact IC Flex ChS/DegThe 930 Compact IC Flex ChS/Deg is the intelligent Compact IC instrument with chemical suppression and built-in degasser. An 800 Dosino is used for the regeneration of the suppressor. The instrument can be used with any separation and detection methods.Typical areas of application:Anion determinations with chemical suppression and conductivity detection; Organic acids with ion-exclusion chromatography and inverse suppression;
2.930.1300
930 Compact IC Flex ChS/PPThe 930 Compact IC Flex ChS/PP is the intelligent Compact IC instrument with chemical suppression and a peristaltic pump for regeneration. The instrument can be used with any separation and detection methods.Typical areas of application:Anion determinations with chemical suppression and conductivity detection; Organic acids with ion-exclusion chromatography and inverse suppression;
- AN-C-178AN-C-178Aspartic acid, glutamic acid, TRIS, sodium, and potassium in cardioplegic solution
A cardioplegic solution protects the ischemic myocardium from cell death. It is applied together with hypothermia e.g. in open heart surgery. Here the simultaneous determination of aspartic acid, glutamic acid, tris(aminomethyl)aminomethane (TRIS), sodium and potassium in such a solution is given. The two amino acids can be determined as they are partially in the triple protonated ammonium form at the eluent pH. Determination is achieved by direct conductivity detection.
- AN-C-179AN-C-179Cations and lactic acid in whey powder applying two separation mechanisms in the same analysis
Whey is the remaining liquid after cheese production. It is mainly used as feed. It is also used as dietary supplement as a beverage or in powder form. This application determines lactic acid as well as cations in one determination. The Metrosep C 6 - 250/4.0 column separates sodium, potassium, magnesium, and calcium by ion exchange. It also acts as an ion-exclusion column, which separates lactic acid. Both lactic acid and the cations can be determined in the same run applying direct conductivity detection. While cations typically elute as negative peaks, lactic acid elutes as an early positive peak. MagIC Net shows both in the usual positive direction.
- AN-C-180AN-C-180Bicine in gas sweetening solvent by cation chromatography
Bicine (2-(Bis(2-hydroxyethyl)amino)acetic acid) is a corrosive component. It has to be avoided in acidic gas sweetening solvents. These solvents are based on organic amines. Bicine is amphoteric, holding a carboxylic and an amine group. Under the applied conditions, the amine groups are at least partially protonated and therefore may be separated by cation chromatography. The detection mode is direct conductivity detection.
- AN-C-181AN-C-181Potassium in potassium bitartrate as per USP
Within the scope of the USP monograph modernization, potassium is determined in potassium bitartrate applying cation chromatography with direct conductivity detection. The USP41 monograph for “Potassium bitartrate” does not yet mention an assay for potassium. The separation is performed on a Metrosep C 6 - 150/4.0 column (L76). The assay of potassium is performed with two commercially available products according to USP definitions. All acceptance criteria are fulfilled.
- AN-C-182AN-C-182Potassium in potassium sodium tartrate as per USP
Within the scope of the USP monograph modernization, potassium is determined in potassium sodium tartrate applying cation chromatography with direct conductivity detection. The USP41 monograph for “Potassium sodium tartrate” does not yet mention an assay for potassium. The separation is performed on a Metrosep C 6 - 150/4.0 column (L76). The assay of potassium is performed with two commercially available products according to USP definitions. All acceptance criteria are fulfilled.
- AN-C-183Potassium in potassium bicarbonate effervescent tablets for oral solution
Within the scope of the USP monograph modernization, potassium is determined in potassium bicarbonate effervescent tablets for oral suspension applying cation chromatography with direct conductivity detection. The separation is performed on a Metrosep C 6 - 150/4.0 column (L76). All acceptance criteria are fulfilled.
- AN-C-184Potassium and sodium bicarbonates and citric acid effervescent tablets for oral solution
As an alternative to flame photometry, ion chromatography with non-suppressed conductivity detection has been approved by the USP as a validated method to quantify potassium and sodium content in potassium and sodium bicarbonates and citric acid effervescent tablets for oral solution. The present IC method has been validated according to USP General Chapter <621>.
- AN-C-185Potassium in potassium bicarbonate and potassium chloride effervescent tablets for oral solution
As an alternative to flame photometry, ion chromatography with non-suppressed conductivity detection has been approved by the USP as a validated method to quantify potassium content in potassium bicarbonate and potassium chloride effervescent tablets for oral solution. The Metrosep C 6 - 150/4.0 column (L76) provides the required separation of potassium and magnesium. The present IC method has been validated according to USP General Chapter <621>.
- AN-C-186AN-C-186Sodium in potassium sodium tartrate as per USP
Within the scope of the USP monograph modernization, sodium is determined in potassium sodium tartrate applying cation chromatography with direct conductivity detection. The USP41 monograph for «Potassium sodium tartrate» does not yet mention an assay for sodium. The separation is performed on a Metrosep C 6 - 150/4.0 column (L76). The assay of potassium is performed with two commercially available products according to USP definitions. All acceptance criteria are fulfilled. See AN-C-182 for the respective determination of potassium. Apllying this method allows to determine sodium and potassium simultaneously according to USP.
- AN-C-187AN-C-187UOP 939-96: Basic Nitrogen in LPG by Ion Chromatography
Natural liquefied petroleum gas (LPG) is a mixture of hydrocarbon gases (e.g. propane and butane), but it also contains acidic contaminants (e.g. carbon dioxide or hydrogen sulfide). These gases need to be scrubbed from the petroleum gas as they are highly corrosive. This purification step, referred to as «sweetening», is often performed by using alkaline amine solutions. Thereby the amine solution absorbs the acidic gases, while the raw LPG is neutralized. To guarantee that amine residues in the sweetened gas do not influence the gas quality, the amines in the final LPG are determined by scrubbing the gas with acetic acid as described in UOP 936-96. The recent method enables the quantification of the amines dimethylamine (DMA), diethylamine (DEA), dipropylamine (DPA), and dibutylamine (DBA) by separation from standard cations.
IR.75
Iridium micro electrode 75 µmIridium micro electrode with a disk diameter of 75 µm.
LACT10
Lactate sensorSuitable for the determination of L(+)-Lactate determination in liquid samples.
MH-110
Screen-printed carbon electrodes with microholesThese disposable screen-printed carbon electrodes consist of a working electrode with 19 spherical microholes distributed hexagonally
PD.100
Palladium micro electrode 100 µmPalladium micro electrode with a disk diameter of 100 µm.
PD.200
Palladium micro electrode 200 μmPalladium disk micro-electrode tip of 200 μm diameter.
PD.25
Palladium micro electrode 25 µmPalladium micro electrode with a disk diameter of 25 µm.
PD.300
Palladium micro electrode 300 µmPalladium micro electrode with a disk diameter of 300 µm.
PD.500
Palladium micro electrode 500 µmPalladium micro electrode with a disk diameter of 500 µm.
P-IDEAU50
Interdigitated gold electrode over plastic substrateGold interdigitated electrodes made on flexible plastic substrate with dimension for bands/gaps of 50 µm. The interdigitated configuration enhances sensibility and detection limits.
P-IDEITO50
Interdigitated ITO electrode over transparent plastic substrateITO interdigitated electrodes made on flexible transparent plastic substrate with dimension for bands/gaps of 50 µm. The interdigitated configuration enhances sensibility and detection limits.
6.07311.290
Septum for Introduction Module (TEI)Septum for liquid injection port of the Introduction Modules (TEI) 6.07311.010, 6.07311.020, 6.07311.030, 6.07311.040.
6.07311.300
Septum cap Liquid Introduction ModuleLid for fastening the 6.07311.290 septum in place in the Liquid Introduction Module.
6.07311.310
Oxygen and UPW supply tubing (TEI)Tubing for oxygen and ultrapure water supply at the inlet to the combustion tube (TEI).
6.07311.350
Replacement filter Combustion Oven (TEI)Spare filter for the fan in the Combustion Oven (TEI).
6.07312.010
Solid sample tray no. 1Solid sample tray no. 1 for the Solid Autosampler CIC (2.0136.0620) for 20 positions.
6.07312.020
Solid sample tray no. 2Solid sample tray no. 2 for the Solid Autosampler CIC (2.0136.0620) for 20 positions.
6.07312.030
Solid sample tray no. 3Solid sample tray no. 3 for the Solid Autosampler CIC (2.0136.0620) for 20 positions.
6.07313.020
Screw incl. ferrule for Liquid Autosampler CIC (TEI)Screw including collapsible ferrule for 1/16" tubing to connect the transfer line to the needle on the Liquid Autosampler CIC (TEI).
6.07313.040
Wash/waste container set for Liquid Autosampler CIC (TEI)Wash/waste container set for the Liquid Autosampler CIC (TEI).
6.07313.050
Prime Vial Set for Liquid Autosampler CIC (TEI)Set of Prime Vials for the preparation of the Liquid Autosampler CIC (TEI).