CVS – Frequently Asked Questions

Problems with Dilution Titration (suppressor determination)

Problems with MLAT/LAT (brightener determination)

Problems with Response Curve (leveler determination)

Problems with the measurement

  • FAQ
    Is it possible to repair a defective driving axle (6.1204.x010 or 6.1204.x20)?
    // Problems with the measurement
  • FAQ
    The electrode test is failing.
    // Problems with the measurement
  • FAQ
    The peak is no longer recognized.
    // Problems with the measurement
  • FAQ
    The measurement curves are noisy.
    // Problems with the measurement
  • FAQ
    The measuring signal for the VMS is fluctuating.
    // Problems with the measurement
  • FAQ
    Are CVS measurements temperature-dependent?
    // Problems with the measurement
  • FAQ
    The measured values are widely scattered.
    // Problems with the measurement
  • FAQ
    The signal is not decreasing despite suppressor addition.
    // Problems with the measurement
  • FAQ
    Conditioning is taking a long time.
    // Problems with the measurement
  • Problems with the hardware

  • FAQ
    I am getting an error message that the dosing unit data cannot be read.
    // Problems with the hardware
  • FAQ
    I am getting an error message. The 800 Dosino cannot be actuated by the 894 Professional CVS.
    // Problems with the hardware
  • FAQ
    The dosing unit is blocked and/or leaking.
    // Problems with the hardware
  • FAQ
    Solution is leaking between the 894 Professional CVS and the measuring head.
    // Problems with the hardware
  • FAQ
    The peristaltic pump on the sample changer is not transferring the entire sample to the measuring vessel.
    // Problems with the hardware
  • FAQ
    The status LED of the 800 Dosino is flashing quickly and the dosing unit is not being recognized.
    // Problems with the hardware
  • FAQ
    An electrode connector on the electrode cable is broken.
    // Problems with the hardware
  • FAQ
    The membrane pumps of the 843 Pump Station are not operating at full pump capacity.
    // Problems with the hardware
  • General problems

  • FAQ
    At what intervals should a dosing unit be cleaned?
    // General problems
  • FAQ
    The measurement curves are noisy. What is the reason for that?
    // General problems
  • FAQ
    How should the additives be stored?
    // General problems
  • FAQ
    Can measurements made using other software be used in viva?
    // General problems
  • FAQ
    Preparing the Dosinos is taking a long time. Is it possible to speed up this step?
    // General problems
  • FAQ
    How frequently do the electrodes need to be conditioned?
    // General problems
  • FAQ
    How should the electrodes be stored?
    // General problems
  • FAQ
    How often should the dosing units be prepared?
    // General problems
  • FAQ
    What preparatory steps need to be taken before shutting down the measuring system?
    // General problems
  • FAQ
    The measuring signal in VMS is exceptionally small and conditioning in VMS is taking a long time. What is the reason for that?
    // General problems
  • Rotating disk electrode

  • FAQ
    How temperature-resistant is the platinum electrode tip?
    // Rotating disk electrode
  • FAQ
    Can platinum electrode tips be polished
    // Maintenance of Rotating Disk Electrodes// Rotating disk electrode
  • FAQ
    The electrode surface of the platinum electrode tip is coated with a foreign metal (Cu, Sn, etc.). What can I do?
    // Maintenance of Rotating Disk Electrodes// Rotating disk electrode
  • FAQ
    Can Metrohm polish platinum electrode tips?
    // Maintenance of Rotating Disk Electrodes// Rotating disk electrode
  • FAQ
    Does the Pt RDE diameter affect my analysis results?
    // Rotating disk electrode
  • FAQ
    How do I clean my platinum electrode tip?
    // Maintenance of Rotating Disk Electrodes// Rotating disk electrode
  • FAQ
    Can the platinum electrode tip be treated in an ultrasonic bath?
    // Maintenance of Rotating Disk Electrodes// Rotating disk electrode
  • Reference electrode

  • FAQ
    Until now, I have always used diluted H2SO4 as a bridge electrolyte. Can I use another electrolyte instead of KNO3?
    // Maintenance of reference electrodes// Reference electrode
  • FAQ
    How often does the bridge electrolyte need changing?
    // Maintenance of reference electrodes// Reference electrode
  • FAQ
    My reference electrode has dried out. Can I regenerate it again?
    // Maintenance of reference electrodes// Reference electrode// Reference electrode// Maintenance of the reference electrode
  • FAQ
    How often do I need to change the reference electrolyte?
    // Maintenance of reference electrodes// Reference electrode
  • Auxiliary electrode

  • FAQ
    The electrode surface of the auxiliary electrode is coated with a foreign metal (Cu, Sn, etc.). What can I do?
    // Maintenance of auxiliary electrodes// Auxiliary electrode
  • FAQ
    Is polishing the platinum pin of the auxiliary electrode allowed?
    // Maintenance of auxiliary electrodes// Auxiliary electrode