Metrohm Inline Sample Preparation and intelligent injection techniques
Intelligent injection techniques and automation solutions for complex sample preparation in ion chromatography analysis.
Highlights
Metrohm has developed various methods to fully automate sample preparation for even the most challenging samples in ion chromatography analyses. Intelligent injection techniques make the analysis even easier and more accurate.
- Fully automated Inline Sample Preparation for liquid, viscous, solid, and gaseous samples
- Prolonged lifetime of the analytical column
- Less consumables needed
- Automation options to save time and improve reproducibility and precision
- Enable ultratrace analysis
Benefits
Automated sample preparation: fast and easy
The Metrohm Inline Sample Preparation (MISP) techniques make sample preparation as easy as it gets. Increase your sample throughput, while also improving accuracy and reproducibility of your analyses and results!
In addition, automated Metrohm IC allows you to use any kind of intelligent injection: full-loop, internal-loop, Metrohm intelligent Partial-Loop Injection Technique (MiPT), and Metrohm intelligent Pick-up Injection Technique (MiPuT). These can be combined with inline sample preparation as preconcentration or matrix elimination to make the analyses even more efficient.
MISP technique | What does it do? | What are the benefits? |
---|---|---|
Metrohm Inline Ultrafiltration | It combines sample introduction with immediate filtration and removes any particles from the sample. | The fully automated sample filtration (0.2 µm) saves time and costs, especially for high-throughput routine analysis. In combination with Inline Dilution, efficiency can be further increased. |
Metrohm Inline Dialysis | It removes particles, oil drops, and colloids from the sample to be analyzed. | The fully automated sample preparation for e.g., dairy products or body fluids, keep manual steps and maintenance costs at a minimum. |
Metrohm Inline Dilution |
It automatically dilutes the sample depending on a predefined concentration limit or logical dilution by automatically calculated optimum dilution factors. | Accurate and reliable results, irrespective of the initial concentration of the sample. Possibility for automatic calibration and multi-stage dilution. |
Metrohm Inline Extraction | It transfers water-soluble components from a non-polar organic phase into an aqueous phase for subsequent injection (after Inline Dialysis). | Facilitates ion chromatographic analysis of water-soluble components of non-polar, organic samples. Low maintenance and costs. |
Metrohm Inline Matrix Elimination | It separates ionic analytes from the uncharged or oppositely charged matrix. | No sample preparation cartridges (SPE) are required, minimizing waste. Elimination of smallest matrix molecules (e.g., isopropanol) not removable with dialyses. |
Metrohm Inline Neutralization and Metrohm Inline Cation Removal | It adjusts the pH (pH 5-7) of strongly acidic or alkaline samples or removes transition metals (for cation removal) using the Sample Preparation Module (SPM), and enables thus direct sample injection (without any risks for column damages). | No time-consuming and expensive sample preparation with SPE cartridges. Reduced risk of precipitation, deposits, and damages of suppressor and columns. Combination with preconcentration, ME, and inline calibration possible enabling even ultratrace analysis. |
Metrohm AeRosol Sampler (MARS) | It samples aerosol particles from an air stream and brings them into the aqueous phase for straightforward IC analysis. | Direct determination of the ionic profile of aerosols with a high time resolution. The direct monitoring avoids any problems related to sample storage and transport. |
Monitor for AeRosols and Gases (2060 MARGA) | It samples the water-soluble ionic load of aerosols and gases/the gas phase of ambient air for subsequent IC analysis. | 24/7, real-time monitoring of anions (SOx, NOx) and cations (NH4+) in parallel. |
Combustion Ion Chromatography (CIC) | It pyrolyzes the sample in an oven unit. Resulting gaseous compounds are transferred into an absorption solution for subsequent direct IC analysis. | High throughput, fully automated inline sample preparation for solids, gases, and liquids. Simultaneous determination of sulfur and halogens with high precision and accuracy. |
815 Robotic Soliprep for LC | It homogenizes, extracts, dilutes, and filters any solid or liquid samples for direct analysis with. | No manual sample preparation steps needed, saving time and costs while keeping the high reliability and accuracy of the results. Compatible with IC and HPLC instruments. |
Systems
Talk to your Metrohm representative and learn about the best solution for your needs!
Effective sample preparation for your IC
Effective sample preparation for your IC
Did you know?
«People you can trust» is the official claim of the Metrohm brand and the fundamental commitment we make to all of our stakeholders.
Show another