Application Finder
- AN-EIS-005Electrochemical Impedance Spectroscopy (EIS) Part 5 – Parameter Estimation
In the application note AN-EIS-004 on equivalent circuit models, an overview of the different circuit elements that are used to build an equivalent circuit model was given. After identifying a suitable model for the system under investigation, the next step in the data analysis is estimation of the model parameters. This is done by the non-linear regression of the model to the data. Most impedance systems come with a data-fitting program. In this application note, the way NOVA is uses to fit the data is shown.
- AN-EIS-006Electrochemical Impedance Spectroscopy (EIS) Part 6 – Measuring raw signals in EIS
In this application note, the advantage of recording the raw time domain data for each individual frequency during an electrochemical impedance measurement is described.
- AN-EIS-007EIS Data fitting – How to obtain good starting values of equivalent circuit elements
Electrochemical impedance spectroscopy (EIS) is a powerful technique which provides information about the processes occurring at the electrode-electrolyte interface. The data collected with EIS are modeled with a suitable electrical equivalent circuit. The fitting procedure will change the values of the parameters until the mathematical function matches the experimental data within a certain margin of error. In this Application Note, some suggestions are given in order to get acceptable initial parameters and to perform an accurate fitting.
- AN-EIS-009Mott-Schottky Analysis
This Application Note presents the Mott-Schottky measurement, an extension of electrochemical impedance spectroscopy (EIS), on a popular semiconducting material.
- AN-FC-001Fuel cells part 1 – what is a fuel cell?
A fuel cell is an electrochemical energy conversion device that produces electricity and heat by electrochemically combining a fuel (typically hydrogen) and an oxidant (typically oxygen). The higher efficiency also results in much lower carbon dioxide emissions and negligible amounts of SOx and NOx (when reformed fuel is used) compared with fossil fuel-based technologies for the same power output.
- AN-FC-002Fuel cells part 2 – types of fuel cells
To overcome the various technical problems, many different fuel cell types have been developed. In this Application Note, proton exchange membrane, direct methanol and solid oxide fuel cells are discussed in more detail.
- AN-FC-003Fuel cells part 3 – characterization using EIS
In this Application Note the use of Electrochemical Impedance Spectroscopy (EIS) for the characterisation of PEM fuel will be demonstrated. It will be shown that EIS is a powerful diagnostic tool for the determination of the following factors that can influence the performance of a PEM fuel cell.
- AN-FC-004Impedance Measurements on Fuel Cells and Fuel Cell Stacks at High Currents: Part 1 – Autolab in combination with an electronic load
In this application note, a combination of PGSTAT and electronic load is use to perform electrochemical impedance spectroscopy in a fuel cell operating at high currents.
- AN-FC-005Impedance measurements on fuel cells and fuel cell stacks at high currents: Part 2 – Autolab in combination with an electronic load
The use of impedance measurements on fuel cells under load makes it possible to study the influence of the different fuel cell elements on the behavior and (if detectable) on the ageing of the fuel cell. To perform high current density measurements, the Autolab systems can be connected to a third party electronic load. This extends the measurable range of the instrument by several current decades.
- AN-FC-006i/V characterization of a fuel cell stack, DC measurements at high current densities
The operational behavior of a fuel cell stack is usually evaluated by determining the polarization and power density curves of the cell. These curves provide a quick characterization of the stack performance and an assessment of its optimal operating conditions (temperature, humidity, electrocatalyst, ion-exchange membrane).
- AN-FET-001Characterization and performance studies of field-effect transistors (FETs) using μStat-i 400
In recent years, field-effect transistors (FETs) have become more commonly used as a sensing platform for a multitude of electrochemical and biological applications. These devices are promising bioelectronic transducers that allow both low-potential operation and stable potentiometric measurements. FETs are now seen as an attractive alternative to using conventional electrochemical detection systems in the scientific community. This Application Note gives in-depth guidance about how to operate Metrohm DropSens bipotentiostat devices for the characterization of FETs and their use as transducers. A single μStat-i 400 device, a small and portable bipotentiostat and galvanostat, is used to demonstrate the experiments.
- AN-FLU-001Fluorescence spectroelectrochemistry of [Ru(bpy)3]2+/3+ in semi-infinite diffusion regime
In this Application Note, the Metrohm DropSens SPELEC instrument is used with the FLUORESCENCE KIT for time-resolved monitoring of electrochemical reactions in a semi-infinite diffusion regime by performing fluorescence spectroelectrochemistry of the [Ru(bpy)3]2+/3+ redox couple.
- AN-FLU-002Understanding the mechanism of a bioassay indicator by fluorescence
Alamar Blue is monitored with fluorescence spectroelectrochemistry during its irreversible reduction to resorufin and further reversible reduction to dihydroresorufin.
- AN-H-001Determination of TAN in oils
Determination of Total Acid Number (TAN) values in mineral oils and similar fluids.
- AN-H-003Determination of sulfate in phosphoric acid
Determination of the sulfate content of wet process phosphoric acid.
- AN-H-004Determination of fluoride by boric acid titration
This Application Note explains how fluoride determination in acid etching baths can be performed with thermometric titration.
- AN-H-005Determination of cuprous ions in the presence of ferrous ions
Determination of cuprous ions in the presence of ferrous ions in electrochemical copper leaching solutions.
- AN-H-006Determination of nonionic surfactants
Determination of a nonionic surfactant of the alkyl propylene oxide derivative type in commercial mixtures containing anionic surfactants.
- AN-H-007Standardization of sodium tetraphenylborate solution
Standardisation of sodium tetraphenylborate (NaTPB) solution for the determination of potassium and for nonionicsurfactants.
- AN-H-008Determination of phosphate by magnesium titration
Determination of soluble orthophosphate ions, for example soluble phosphate in fertilizers such as DAP.
- AN-H-009Determination of sulfate in brines
Determination of the sulfate content of brines.
- AN-H-010Determination of calcium in drilling fluids
Thermometric titration quickly and accurately assesses the total solids content of fluids employed in drilling oil and gas wells within minutes.
- AN-H-011Determination of the total solids content of drilling fluids
Thermometric titration is presented as a simple, fast, and reliable method to determine calcium content in various drilling fluids.
- AN-H-012Determination of ferrous ion content of heat exchanger wash solutions
Determination of ferrous ions in heat exchanger and vessel acid wash solutions, for measuring the effectiveness of acid inhibitors used in the solutions. Depending on the condition of the sample, the lower practical limit for the determination will vary from approximately 20-100mg/Kg Fe2+. Samples with high silicic acid contents require relatively large amounts of dilution water to render them mobile, and this limits the aliquot size and hence the amount of Fe2+ which can be analyzed.
- AN-H-013Determination of moisture content of ultrafine solids
Determination of water in moist particulate solids such as cobalt oxyhydroxide.
- AN-H-014Determination of free acid content of solutions containing Fe(III)
Determination of free acid in solutions containing metal ions, particularly Fe(III).
- AN-H-015Determination of acetic anhydride in acylation mixtures
Determination of acetic anhydride in the presence of acetic acid in acylation mixtures.
- AN-H-016Determination of acetic, phosphoric, and nitric acid mixtures
Determination of mixtures of phosphoric, nitric, and acetic acids used in etching aluminum in the manufacture of semiconductor devices.
- AN-H-017Determination of bromide and chloride in photographic developer solutions
Determination of bromide and chloride in photographic developer solutions.
- AN-H-018Determination of chloride in drilling fluids
Determination of chloride in oil well drilling fluids.
- AN-H-019Determination of chlorine in household bleaches
Determination of chlorine in household bleaches.
- AN-H-020Determination of chromium in leather waste solutions
Determination of chromium in leather waste solutions in the range between 1000 and 30,000 ppm.
- AN-H-021Determination of free acid in copper refining solutions
Determination of free acid in copper refining solutions.
- AN-H-022Determination of moisture in lubricating oils with TEOF
Determination of moisture in lubricating oils with TEOF (triethyl orthoformate).
- AN-H-023Determination of nickel by dimethylglyoxime titration
Determination of nickel in the absence of cobalt and other interferences.
- AN-H-024Determination of tar acids (phenolics) in tar products
Determination of tar acids in coal tar products. This procedure may also be applied to the determination of a range of weakly acidic organic compounds such as carboxylic acids, hydroxy acids, phenols, phenolic acids, keto-enols, imides, and aromatic nitro compounds.11 Vaughan, G. A. Thermometric and Enthalpimetric Titrimetry. Van Nostrand Reinhold Co. Ltd (1973)
- AN-H-025Determination of moisture in lubricating oils by DMP
Determination of water in automotive lubricating oils.
- AN-H-026Determination of causticizer, carbonate and aluminum oxide in Bayer process liquor
This Application Note describes a method for the determination of causticizer, carbonate and aluminum oxide in used Bayer process liquors. The method is based on processes that were developed by Watts-Utley and VanDalen-Ward.
- AN-H-027Determination of organic soda in Bayer aluminate liquors
Determination of total basicity of extractable organic compounds of acidic character in Bayer process refinery liquors.
- AN-H-028Standardization of 0.1 mol/L KOH in propan-2-ol
Standardization of 0.1 mol/L in propan-2-ol for use in applications for the determination of weakly acidic species in non-aqueous media.
- AN-H-030Determination of chlorite by direct titration with thiosulfate
Determination of chlorite by direct thermometric titration with standard sodium thiosulfate solution. The procedurewas applied originally to the determination of chlorite in hide treatment solutions.
- AN-H-031Determination of low levels of sulfate by barium chromate displacement
Determination of low levels of sulfate (to approximately 20mg/L SO42-) by thermometric titration.
- AN-H-032Standardization of ammonium ferrous sulfate solution
Standardization of 0.1 mol/L ammonium ferrous sulfate solution for use in thermometric titration of Cr(VI) solutions.
- AN-H-033Determination of low levels of chloride in water
Determination of low levels of chloride (to approximately 5 mg/L Cl-) by thermometric titration.
- AN-H-034Determination of calcium and magnesium in process samples
Determination of calcium and magnesium in process solutions.
- AN-H-035Phosphate in fertilizers – Rapid and reliable determination by thermometric titration
Phosphorus is a primary macronutrient for plants and is a constituent of DNA and adenosine triphosphate (ATP), which is involved in many biological processes requiring energy. In fertilizers, phosphorus is present in the form of phosphate, as the most accessible form of phosphorus for plants is dihydrogen phosphate. Knowledge of the phosphorus content helps to select the right fertilizer for the plants.Traditionally, phosphate is determined gravimetrically (a time consuming procedure) or spectrophotometrically (expensive instrumentation). In this Application Note, an alternative method is presented, where phosphate is determined by a precipitation titration with magnesium. Various solid and liquid NPK fertilizers with phosphorus contents between 6.5 and 17% were analyzed. The analysis by thermometric titration requires no sample preparation in case of liquid NPK fertilizers and only minimal sample preparation in case of solid NPK fertilizers. One determination takes about 5 minutes.
- AN-H-036Determination of free fatty acids (FFA) in olive oil
Determination of free fatty acids (FFA) in oils.
- AN-H-037Determination of phosphate in an acid etching mixture
Determination of phosphate content in an acid etching bath.
- AN-H-038Determination of sulfate and total acids in a nitrating mixture
Determination of sulfate and total acids in a nitrating mixture.
- AN-H-039Determination of sodium lauryl ether sulfate
Determination of sodium lauryl ether sulfate surfactants.
Did you know?
The over 500 titration applications on our website are only the tip of the iceberg of our application knowledge.
Show another