- 410000009-ARapid Identification of Heroin with Handheld Raman
Raman spectroscopy is used widely by law enforcement as a field screening tool due to its speed, selectivity and ease of use. The majority of materials can be identified by the Raman signature, as they exhibit sharp distinctive peaks serving as a molecular fingerprint. However, many street and real-world samples are dark in color and not pure. The dark color, often due to impurities, gives rise to fluorescence that interferes with the Raman measurement. One method to suppress the fluorescence of a sample and enhance the Raman activity / signal is by the use of Surface-Enhanced Raman Spectroscopy (SERS).
- 410000012-A01Rapid Detection of the Low Dose API in Xanax Using Surface-Enhanced Raman Spectroscopy for Anti-Counterfeiting Purposes
The emergence of counterfeit prescription drugs has become a concern for the pharmaceutical industry. Because of the low concentrations of APIs found in pharmaceutical drugs, normal Raman spectroscopy is typically not sensitive enough to detect the API from the surface of a pill. In this study we develop a surface-enhanced Raman spectroscopy (SERS)-based approach to identify a low-dose of the API alprazolam in a Xanax tablet using a handheld Raman spectrometer. If no SERS peaks consistent with alprazolam are observed from a Xanax tablet, the pill is a suspected fake. The method demonstrates the power of SERS to quickly verify the presence of alprazolam in the tablet for anti-counterfeiting purposes.
- 410000017-ARaman for See Through Material Identification Application Note
A new Raman system design is presented that expands the applicability of Raman to See Through diffusely scattering media such as opaque packaging materials, as well as to measure the Raman spectrum and identify thermolabile, photolabile, or heterogeneous samples.
- 410000021-APortable Raman Spectroscopy in Forensics: Explosive Residues and Inflammable Liquids
The suitability and potential of Raman spectroscopy in forensics is widely known by forensic specialists who use it in the laboratory to identify a wide variety of compounds including explosives, drugs, paints, textile fibers and inks. However, the use of laboratory-grade Raman outside the laboratory, such as for in‐situ analysis at a crime scene, was something thought possible only in forensic‐fiction until just a few years ago. Fortunately, modern portable Raman spectrometers are commercially available, and their instrumental features are comparable to Raman lab‐ spectrometers. To prove this, some extraordinarily demanding and challenging applications, in which an in‐situ standoff identification of samples might be advisable, were tested.
- 410000024-BRaman solution suite for forensics applications
Law enforcement personnel, laboratory technicians, crime scene investigators and many others face a significant challenge for identification of materials in a forensic investigation.Traditionally, technicians used multiple forms of identification in order to collect results from various forms of forensic samples. Although certain technologies are ideal for precise laboratory identification, many technologies, such as Raman spectroscopy, can be successfully used for identification of multiple forensic sample types either directly in the field or in the lab. Raman spectroscopy is classified as a Category A analytical method by the Scientific Working Group for the Analysis of Seized Drugs (SWGDRUG; Version 7.1, 2016).
- 410000025-AIdentification of Forensic Fabrics Using a Portable Raman Spectrometer
At a crime scene, a police officer collects a fiber sample that may prove to be invaluable evidence in identifying a criminal or exonerating an innocent person. In recent years, Raman spectroscopy has been studied extensively for forensic fiber analysis because of the high selectivity of Raman signatures, non-destruction nature of the test, and the ability to conduct the analysis without any sample preparation. The Raman spectrum can be measured directly on fabrics or fibers mounted on glass slide with very little interference from the mounting resin or the glass.
- 410000029-ASee Through Raman Technology: Expanded capabilities for through package identification using 785 nm and 1064 nm excitation Raman
See through Raman Spectroscopy (STRaman®) is a newly developed technology that expands the capability of Raman spectroscopy to measure samples beneath diffusely scattering packaging material. The STRaman technology features a much larger sampling area than the confocal approach. This design enhances the relative intensity of the signal from the deeper layers, thereby increasing the effective sampling depth, allowing the measurement of material inside visually opaque containers. The larger sampling area has the additional advantage of preventing sample damage by reducing the power density, as well as improving measurement accuracy by eliminating heterogeneous effect.
- 410000031-ARapid Field Testing of Ecstasy Pills Using a 1064-nm Handheld Raman Device
B&W Tek’s TacticID®-1064 is a field-ready handheld Raman system utilizing 1064-nm wavelength laser excitation. Designed for forensic analysis by safety personnel, first responders, and law enforcement personnel, the TacticID-1064 significantly reduces fluorescence, allowing users to identify tough street samples such as ecstasy tablets in a variety of colors and mixture forms.
- 410000035-AB&W Tek TacticID for Narcotics Identification
Forensics testing of samples encountered by law enforcement and customs agents is based on analytical techniques that are now being miniaturized and simplified and are making their way into field instrumentation. Field testing with Raman spectroscopy allows users to conduct reliable measurements at the point of arrest, reducing the burden on crime labs and accelerating the prosecution process.
- 410000052-ASee-Through Measurements of Illicit Substances in Commercial Containers with the TacticID®-1064 ST
The TacticID®-1064 ST is a 1064 nm handheld Raman system designed for law enforcement officials, first responders, and customs and border protection officers for rapid field identification of illicit substances such as narcotics, explosives, and other suspicious materials. The TacticID-1064 ST is specially designed with see-through Raman functionality to measure materials through both transparent and opaque containers. These through-barrier measurements remove the need for active sampling of potentially dangerous compounds such as fentanyl, leading to safer operations and reduced wait time for clear results.
- 410000056-ACounterfeit Adderall Pills Identification with TacticID Mobile
In this case study, a suspected counterfeit Adderall pill was measured directly with a TacticID Mobile using a point-and-shoot adapter. The spectra of the suspected couterfeit pill was found to contain cellulose and caffeine, but not the active ingredient. The TacticiD Mobile with 1064-nm laser excitation provides fluorescence suppression, giving those on the front lines a tool in the fight against dangerous counterfeit drugs.
- AB-046Potentiometric determination of cyanide
The determination of cyanide is very important not only in electroplating baths and when decontaminating wastewater but, due to its high toxicity, also in water samples in general. Concentrations of 0.05 mg/L CN- can already be lethal for fish. This Bulletin describes the determination of cyanide in samples of different concentrations by potentiometric titration. Chemical reactions: 2 CN- + Ag+ → [Ag(CN)2]- [Ag(CN)2]- + Ag+ → 2 AgCN
- AB-404Total acid number titration of petroleum products
The determination of the acid number plays a significant role in the analysis of petroleum products. This is manifested in the numerous standard procedures in use over the world (internal specifications of multinational companies, national and international specifications of ASTM, DIN, IP, ISO, etc.). These procedures differ mainly in the composition of the used solvents and titrants.This bulletin describes the determination of the acid number in petroleum products by applying different types of titration.The potentiometric determination is described according to ASTM D664, the photometric according to ASTM D974 and the thermometric titration according to ASTM D8045.
- AB-405Total base number titration of petroleum products
This Application Bulletin shows the determination of the total base number in petroleum products by applying different titration types according to various standards.
- AB-427Acid number in petroleum products with thermometric titration
This Application Bulletin describes the determination of the total acid number in various oil samples by catalytic thermometric titration as per ASTM D8045.
- AN-COR-010Electrochemical Corrosion Studies of Various Metals
Corrosion of metals is a problem seriously affecting not only many industrial sectors, but also private life, resulting in enormous costs. In this application note, the results gained during electrochemical corrosion studies on different metals are compared to literature data.
- AN-COR-018Evaluation of organic coatings on metals using Autolab PGSTAT based on ISO 17463 – Paints and Varnishes
The International Standard ISO 17463 describes the determination of the anticorrosive properties of high impedance organic protective coatings on metals. This technique uses cycles composed of electrochemical impedance spectroscopy (EIS) measurements, cathodic polarizations and potential relaxation. This application note shows the compliance of the Metrohm Autolab PGSTAT M204 and flat cell with the standard ISO 17463.
- AN-EC-002Reference electrodes and their usage
A reference electrode has a stable and well-defined electrochemical potential (at constant temperature), against which the applied or measured potentials in an electrochemical cell are referred. A good reference electrode is therefore stable and non-polarizable. In other words, the potential of such an electrode will remain stable in the used environment and also upon the passage of a small current. This application note lists the most used reference electrodes, together with their range of use.
- AN-EIS-003Electrochemical Impedance Spectroscopy (EIS) Part 3 – Data Analysis
Here, the most common circuit elements for EIS are introduced which may be assembled in different configurations to obtain equivalent circuits used for data analysis.
- AN-EIS-005Electrochemical Impedance Spectroscopy (EIS) Part 5 – Parameter Estimation
In the application note AN-EIS-004 on equivalent circuit models, an overview of the different circuit elements that are used to build an equivalent circuit model was given. After identifying a suitable model for the system under investigation, the next step in the data analysis is estimation of the model parameters. This is done by the non-linear regression of the model to the data. Most impedance systems come with a data-fitting program. In this application note, the way NOVA is uses to fit the data is shown.
- AN-EIS-006Electrochemical Impedance Spectroscopy (EIS) Part 6 – Measuring raw signals in EIS
In this application note, the advantage of recording the raw time domain data for each individual frequency during an electrochemical impedance measurement is described.
- AN-EIS-007EIS Data fitting – How to obtain good starting values of equivalent circuit elements
Electrochemical impedance spectroscopy (EIS) is a powerful technique which provides information about the processes occurring at the electrode-electrolyte interface. The data collected with EIS are modeled with a suitable electrical equivalent circuit. The fitting procedure will change the values of the parameters until the mathematical function matches the experimental data within a certain margin of error. In this Application Note, some suggestions are given in order to get acceptable initial parameters and to perform an accurate fitting.
- AN-NIR-064Quality control of ammonium nitrate
Specialty chemicals have to fulfill multiple quality requirements. One of these quality parameters, which can be found in almost all certificates of analysis and specifications, is the moisture content. The standard method for the determination of moisture content is Karl Fischer titration.This method requires reproducible sample preparation, chemicals, and waste disposal. Alternatively, near-infrared spectroscopy (NIR) can be used for the determination of moisture content. With this technique, samples can be analyzed without any preparation and without using any chemicals.
- AN-RA-007Enhancement of Raman intensity for the detection of fentanyl
Fentanyl, a powerful synthetic opioid, is illegally distributed worldwide. Overdosing can be fatal, causing symptoms like stupor, pupil changes, cyanosis, and respiratory failure. Just 2 mg of fentanyl can be lethal, depending on factors like body size and past usage. Given its severe impact, identifying and detecting fentanyl is crucial, as it has become a major public health crisis. Combining electrochemical surface-enhanced Raman spectroscopy (EC-SERS) with screen-printed electrodes (SPEs) offers a fast, effective, and precise method for detecting fentanyl.
- AN-RS-012Acid Attack Prevention: – Identification of Acids through a Novel Plastic Container
Acid throwing, a historical method for retribution against women, has become a modern threat of a different nature. Concentrated acids and other corrosive substances have emerged as modern tools of social violence. Aggressors use common plastic containers with openings that create a powerful directional spray, such as lemon juice squeeze bottles. Sulfuric and phosphoric acids were chosen for analysis here due to their highly corrosive nature- acid attacks in London most commonly use sulfuric, phosphoric, and nitric acids. 2017 saw a remarkable number of acid attacks in the UK, with reported incidences averaging 2x a day. Detection and regulation of acids may contribute to prevention of this social scourge.
- AN-RS-013Determination of Container Contents
Identification of unknown materials in the field can be a complicated affair, especially in critical situations, where speed, safety, and ease-of-operation are essential. Mira DS, Metrohm Raman’s handheld Raman analyzer, and the intelligent Universal Attachment (iUA) give the user automated Content ID capabilities. Content ID achieves through container identification of unknown materials quickly, easily, and safely.
- AN-RS-032Raman and SERS identification of a combination prescribed opioid
Handheld Raman spectrometers are valued for their ability to provide onsite material identification in seconds. In the case of combination pharmaceuticals, a single tablet contains more than one active ingredient in different proportions. MIRA DS is uniquely capable of identifying multiple compounds in such tablets by using Raman to identify the major component and SERS (surface-enhanced Raman spectroscopy) for the minor component. This application describes quick, dual analysis of a prescription medication containing acetaminophen and hydrocodone. The application is easily extrapolated to the study of street drugs.
- AN-RS-033Raman and SERS identification of YABA, a popular street drug
Yaba, produced in Southeast Asia, is a popular drug of abuse and is actively targeted by police squads. Two strong and highly addictive stimulants make up Yaba: caffeine, which comprises up to 60% of each tablet, and methamphetamine at approximately 20%. Identifying these two active ingredients in different proportions in a colorful tablet with other excipients could be an analytical nightmare. With handheld Raman, bulk material identification is achieved in seconds onsite with simple point-and-shoot analysis. SERS (surface-enhanced Raman spectroscopy) analysis is used to detect the minor component in mixtures without interference from fillers, dyes, and coatings. MIRA DS is uniquely capable of both analyses—Raman testing positively identifies caffeine in Yaba, while methamphetamine can be detected with SERS sampling. This application describes quick, dual analysis of Yaba tablets with MIRA DS.
- AN-RS-035Fentanyl in the Mail
Raman analysis of fentanyl-soaked paper, SERS detection range for fentanyl on paper, and real-world example of fentanyl identification.
- AN-RS-038Detection of LSD on Blotter Paper
With MISA and MIRA, easy-to-use test kits and flexible sampling allow rapid and accurate interrogation of suspect materials with minimal time, training, and expense.
- AN-RS-038Detection of LSD on Blotter Paper
- AN-RS-040Trace Detection of DMT in Plant Matter
Modern recreational use of DMT (N,N-Dimethyltryptamine) is growing and although it is legally protected in some countries, new legislation attempts to reduce its abuse and associated adverse health effects. MIRA XTR DS from Metrohm Raman provides rapid and sensitive detection of DMT in the field.
- AN-S-236Drinking water quality by EPA 300.1
Clean drinking water is cited as a human right by WHO. Policies, standards, and robust and reliable analytical methods are required to safeguard water quality, and by extension, public health. US EPA Method 300.1 is the main standard method for the analysis of inorganic disinfection byproducts (oxyhalides: chlorite, chlorate, bromate) and common inorganic anions (fluoride, nitrite, bromide, nitrate, sulfate, and phosphate) as well as dichloroacetate (DCA) in drinking water. The requirement of using two injections, one for the standard anions and a second for the trace anions, reduces the sample throughput for the laboratories dramatically. Metrohm ion chromatography (IC) with suppressed conductivity detection using the highly selective Metrosep A Supp 7 column fulfills these requirements in a single-run analysis, increasing laboratory efficiency and saving money while keeping analytical quality high.
- AN-S-395Forensic examination analysis with IC
Forensic institutes examine terrorist attacks and warfare agents via trace detection analysis of the used explosives and their residuals. Of particular importance is the acquisition of «chemical fingerprints» for criminal investigation departments and governmental security agencies. Institutes for public health and environmental protection analyze such compounds that can contaminate the underlying soil and infiltrate ground water. Forensic investigation with ion chromatography (IC) using suppressed conductivity detection allows a sensitive and robust determination of anionic contaminants such as chlorate, thiosulfate, thiocyanate, and perchlorate next to the common inorganic anions over a broad concentration range.
- AN-T-094Fully automated determination of the permanganate index according to EN ISO 8467
The automated system MATi 13 determines the permanganate index in all kind of water samples according to EN ISO 8467. The high degree of automation (e.g., automated sample addition, automated titer and blank value determination) minimizes errors and guarantees robust and reproducible results.
- AN-T-217Hypochlorite and sodium chloride in disinfectant
Sodium hypochlorite and sodium chloride can be effectively use as disinfectant for water and surfaces. The World Health Organization (WHO) recommends, depending on the application, concentrations in disinfectants of 1000 mg/L to 5000 mg/L NaOCl and up to 200 g/L NaCl.This Application Note demonstrates a reliable method to determine the hypochlorite and sodium chloride content in disinfectants by two subsequent argentometric titrations in the range recommended by the WHO.
- AN-V-221Cadmium and lead in drinking water
To reduce the toxic effects of cadmium on the human body, as well as to limit the neurotoxic effects of lead, the provisional guideline values in the World Health Organization’s «Guidelines for Drinking-water Quality» are set to a maximum concentration of 3 µg/L for cadmium and 10 µg/L for lead. The completely mercury-free Bi drop electrode takes the next step towards converting voltammetric analysis into a non-toxic approach for heavy metal detection. Using this environmentally friendly sensor for anodic stripping voltammetry (ASV) allows the simultaneous determination of Cd and Pb in drinking water. The outstanding sensitivity is more than sufficient to monitor the provisional WHO guideline values.
- AN-V-227Chromium(VI) in drinking water
The guideline value for chromium in the World Health Organization’s (WHO) «Guidelines for Drinking-water Quality» is 50 µg/L. It should be noted here that chromium concentrations are often expressed as total chromium and not as chromium(III) or (VI). Chromium(VI) is responsible for changes in genetic material, and is found in significantly lower concentrations than Cr(III). Therefore an extremely sensitive method is required to monitor Cr(VI) in drinking water. The powerful adsorptive stripping voltammetry (AdSV) technique on the ex-situ mercury film modified glassy carbon electrode using DTPA as complexing agent can be used to determine such low concentrations.
- AN-V-230Chromium(VI) in drinking water
The guideline value for total chromium in the World Health Organization’s (WHO) «Guidelines for Drinking-water Quality» is 50 µg/L. Chromium(VI) is more toxic than its trivalent form (Cr(III)) and is also less abundant. Therefore a robust and sensitive method is required to monitor its concentration in drinking water. The mercury film modified scTRACE Gold can be used to monitor chromium(VI), offering easy handling and a high grade of stability.
- BWT-4910The Use of Portable and Handheld Raman for Forensic Investigations
Today's Raman instrumentation is faster, more rugged, and less expensive than in the past and the advances in component miniaturization have led to the design of portable devices with extremely high performance designed for field-based investigations. This study focuses on the use of handheld Raman spectroscopy for the characterization and identification of samples encountered in various application areas related to forensic science.
- BWT-4912Quantitative Analysis Using New Generation Raman Spectrometers and Chemometrics ─ Smaller and Faster
Small, fast high-performance Raman spectrometers are now readily available. Three real-life Raman quantitative and semi-quantitative analysis applications are discussed. These applications showcase the versatility of Raman spectroscopy and the potential impact that it can make in various industries such as security, pharmaceutical, and plastics and polymers.
- BWT-4914Raman Spectroscopy Peers Through Packaging
Patented STRaman technology is a new Raman technique that can identify chemical species nondestructively beneath diffusely scattering packaging material such as plastics or tablet coatings.
- BWT-4916See-Through Science
Allowing non-destructive chemical identification through opaque materials, award-winning STRam represents an evolution in Raman technology.
- WP-012Corrosion control: Thermometric TAN analysis in oil & refinery distillation fractions
Many refiners look at discounted opportunity crudes as a means to improve their margin spread. The varieties of these cheap crude oils on the market are growing in number, but they have hidden risks for the purchaser caused by factors such as high naphthenic acid and sulfur content. Sulfur compounds and naphthenic acids are among the substances that contribute to the corrosive nature of crude oils and petroleum products. This is why the risk of corrosion is increased when processing crude oils with high naphthenic acid and sulfur content. The refiner must balance the cost benefit versus the risk and the cost of corrosion control when processing these crudes. A reliable acid number determination is a crucial part of corrosion control. Guest authors Bert Thakkar, Bryce McGarvey, and Colette McGarvey of Imperial Oil and Larry Tucker and Lori Carey of Metrohm USA were involved in the development of the new ASTM Method D8045 for acid number determination. Here, they report on the method and how it came to be.
- WP-026Surface Enhanced Raman Scattering (SERS) – Expanding the Limits of Conventional Raman Analysis
Surface Enhanced Raman Scattering or SERS is an anomalous enhancement of Raman scattering when molecules are adsorbed to gold or silver nanoparticles – this enhancement can be as large as 107. The advantage of SERS for the analytical chemist lies in its ability to detect analyte concentrations of parts per million and even parts per billion levels, while classical Raman is limited to parts per thousand. Metrohm Raman produces P-SERS assays in the form of nanoparticles printed onto substrates using inkjet technology. This method produces inexpensive test strips that exhibit exceptional stability and sensitivity. There are two markets that can be easily addressed with P-SERS: forensic analysis and food safety. This white paper explains the mechanism of SERS and how it can be applied to handheld Raman analysis with Metrohm Raman Mira systems.
- WP-027Smart Acquire – Automated Raman Material ID for Defense and Security Professionals
An analytic chemist in your back pocket. A forensic laboratory in a suitcase. A HazMat team in the trunk of your car. First responders need all the help they can get when faced with potentially dangerous substances. Mira DS from Metrohm Raman is a sophisticated chemical analyzer that replaces the specialist with automation. The push of a button initiates proprietary Smart Acquire routines to optimize acquisition parameters and collect the highest quality spectra. These spectra are automatically subjected to library search and Mixture Matching routines capable of identifying up to three components of a mixture. When hazardous substances are detected, the user is alerted to immediate action with color-coded warnings.
- WP-028Safety in Any Situation – Addressing the needs of first responders
Metrohm Raman presents a unique handheld materials identification system designed to meet the needs of defense and security professionals. Meet Mira DS, the most adaptable Raman analyzer available today. Mira DS was developed directly in response to requests from first responders in the field for a small, rugged, automated materials identification system that ensures the safety of the user in any situation.
- WP-032Creating Custom Libraries Detection of Binary Explosives with Mira DS
Detection of threatening materials requires robust and sophisticated instruments capable of safe, instantaneous field-analysis of unknowns. In an environment where there is an ever-evolving threat of explosives made from commonly available chemicals, explosive libraries must be customized constantly to include newly targeted materials. Mira DS from Metrohm Raman is the perfect solution for detection of explosives in the field. This handheld Raman instrument is equipped with sophisticated analysis algorithms and a suite of safety features for first responders who need the identity of a potential hazard... NOW! Mira DS and its software can be customized to respond to emerging hazards: this note describes procedures for creating custom libraries of binary explosive precursors to be used in library comparison and mixture matching routines on Mira DS. With these tools, unknown substances can be identified with color-coded warnings for fast action in critical situations.
- WP-033Identifying Narcotics in Complex Samples
A person suspected of possessing a narcotic can be charged with a crime only after the identity of the illicit substance is confirmed. This confirmation is typically provided by analytical chemists in forensic laboratories and requires highly technical separation and detection methods. Unfortunately, such labs often have deep caseloads that lead to delays in testing. Handheld Raman analyzers bring the reliability and accuracy of lab analysis to first responders in the field, allowing for rapid and accurate identification of street drugs with a white powder appearance. With such tools, demand for forensic analysis can be reduced and enforcement agencies can enforce drug policies with greater safety, speed, and precision.
- WP-034Determination of Heroin in Street Drug Samples
Printable Surface Enhanced Raman Scattering (P-SERS) silver substrates were used with Metrohm Raman’s Mira DS handheld Raman analyzer to successfully detect heroin in 18 crude street heroin samples. Detection of heroin with P-SERS was accomplished easily and very quickly, with minimal sample clean-up. Solvent studies were also implemented to determine the optimal solvent for crude sample extraction, with results included here.