Fluoride Ion Selective Electrode (ISE) launched

New Fluoride ISE available as digital and analog sensor versions

21. 9. 2021

Novinky

The new Fluoride ISE from Metrohm combines the measuring electrode, the reference electrode, and a temperature sensor in a space saving design making it ideal for measurements in small sample volumes. The new sensor is available both in an analog and a digital version.

The fluoride-selective electrode is a dedicated electrode to measure fluoride concentration (10-6 mol/L to sat.). For stable signals and reproducible results even in contaminated samples, the Fluoride ISE features a ground-joint diaphragm with a large surface. This allows for a constant electrolyte outflow, reducing the risk of a blocked diaphragm.

As the potential in the sample solution is influenced by the temperature, the combined fluoride ion-selective electrode features an integrated temperature sensor to determine the temperature of both the calibration and the sample solution.

Combined Fluoride ISE

  1. Fast, stable, and accurate results for ion measurements of F- (10-6 mol/L to sat.)
  2. Easy cleaning of ground-joint diaphragm
  3. Ideal for automated ion measurements (direct measurement and standard addition) and titration
  4. Compact design combining three sensors into one: measuring electrode, reference electrode, and temperature sensor

How do fluoride ion-selective electrodes work?

Learn more about fluoride-selective electrodes in the application bulletin and video:

Application bulletin: Determination of fluoride with an ion-selective electrode

0:00 / 4:25

Metrohm is pleased to launch the Fluoride ISE, a dedicated sensor for selective measurements of fluoride. The new sensor combines the measuring electrode, the reference electrode, and a temperature sensor in a space saving design making it ideal for measurements in small sample volumes. The new sensor is available both in an analog and a digital version.

For stable signals and reproducible results even in contaminated samples, the Fluoride ISE features a ground-joint diaphragm with a large surface providing for a consistent electrolyte outflow reducing the risk of a blocked diaphragm.

As the potential in the sample solution is influenced by the temperature, the Fluoride ISE features an integrated temperature sensor to determine the temperature of both the calibration and the sample solution.

Download flyer to learn more

Download pr in English