AN-H-026

Determination of causticizer, carbonate and aluminum oxide in Bayer process liquor


Summary

This Application Note describes a method for the determination of causticizer, carbonate and aluminum oxide in used Bayer process liquors. The method is based on processes that were developed by Watts-Utley and VanDalen-Ward.