응용 분야 및 기법
- AN-H-143Sulfuric acid and tartaric acid in tartaric sulfuric anodizing bath – Rapid, sequential determination using a thermometric sensor (thermometric titration)
Tartaric Sulfuric Anodizing (TSA) is an established technique for corrosion protection in the aerospace industry. It is an alternative to the environmentally harmful chromic anodizing process. As such, a method to monitor the levels of sulfuric acid and tartaric acid in TSA plating baths is required. Potentiometric titration methods have been developed, and are widely used across the industry. Their disadvantage is that two titrations with different electrodes and solvents are required.In this Application Note, an alternative method is presented, where the concentration of both acids is determined in sequence using a thermometric sensor. Compared to potentiometric titration, thermometric titration is faster and more convenient (no sensor maintenance required). On a fully automated system, the determination of both parameters takes about 7 minutes.
- 8.000.6066Determination of the total acid number (TAN) using thermometric titration
The thermometric titration method presented here permits a simple and direct determination of the total acid number (TAN) in petroleum products. It is an invaluable alternative to current manual and potentiometric methods. Thermometric titration uses a maintenance-free temperature sensor that does not require rehydration and is free of fouling and matrix effects. The procedure requires minimal sample preparation. Results agree closely with those from the potentiometric titrimetric procedure according to ASTM D664, but the thermometric titration method is far superior in terms of reproducibility and speed of analysis, with determinations being complete in approximately one minute.
- AB-313Analysis of Bayer process liquors using thermometric titration
The determination of the total causticizer, sodium carbonate and aluminum oxide contents in (Bayer) process liquors can be accomplished with high precision and speed by using the 859 Titrotherm in a thermometric acid-base titration. A complete titration takes approximately 5 minutes.The procedure is an automated adaptation of the traditional Watts-Utley method, and is similar to the VanDalen-Ward thermometric titration method, but with the added advantage that the analysis can also be performed for the carbonate content of the liquor.
- AB-427Acid number in petroleum products with thermometric titration
This Application Bulletin describes the determination of the total acid number in various oil samples by catalytic thermometric titration as per ASTM D8045.
- AN-H-127Thermometric analysis of aluminum by back-titration
This Application Note describes the determination of aluminum in samples containing silicon dioxide using thermometric titration and EDTA as the titrant. Excess EDTA is titrated with a Cu2+ solution of known concentration. The initial, uncomplexed Cu2+ ions react immediately with the H2O2 present in the solution, leading to a recognizable sudden increase in temperature.
- AN-H-132Thermometric endpoint titration of hydrogen peroxide with iodometry
Hydrogen peroxide solutions can be determined through thermometric endpoint titration (TET) using iodometry. Iodide is oxidized to become iodine, which is then titrated with a standard thiosulfate solution in an exothermic reaction.
- AN-H-090Nickel in electroless nickel solutions by thermometric EDTA titration
Automated thermometric titration of the nickel content of electroless nickel plating solutions. The determination is suitable for fully automated titration employing a 814 Sample Processor.
- AN-PAN-1037Online thermometric titration of acid number (AN) in oils (ASTM D8045)
Metrohm has partnered with industry leaders to develop an alternative standard for the measurement of acid number (AN) in crude oil and petroleum products to overcome shortcomings in the current method (ASTM D664). This new standard method (ASTM D8045) describes the use of thermometric catalytic titration for this analysis. Results agree closely with those from ASTM D664, but the thermometric catalytic titration method is far superior in terms of reproducibility and speed of analysis, with determinations being complete in one minute.Solvent usage is much less compared to older methods, saving on waste disposal cost. Comparison studies show very close data correlation between ASTM D8045 and traditional potentiometric AN titration methods making implementation into a refinery with historic data practical.
- AN-H-129Determination of weak bases in nonaqueous media through catalyzed thermometric endpoint titration (CETT)
Weak, organic bases that are soluble in nonaqueous solvents (including nonpolar solvents) are determined in glacial acetic acid using titration with strong acids, e. g., anhydrous perchloric acid or trifluoromethanesulfonic acid. The endpoint of such titrations can be determined thermometrically, insofar as a suitable thermometric endpoint indicator exists. The exceptional suitability of isobutyl vinyl ether (IBVE) as indicator has been demonstrated.
- AB-066Potentiometric and thermometric determination of boric acid
Boric acid is used in many primary circuits of nuclear power plants, in nickel plating baths, and in the production of optical glasses. Furthermore, boron compounds are found in washing powders and fertilizers. This bulletin describes the potentiometric and thermometric determination of boric acid. The determination also covers further boron compounds, when acidic digestion is applied.