アプリケーション検索(技術資料)
※ 並び替えをz-a 順にすると、概要を日本語に訳したアプリケーションが上位に表示されやすくなります。
※ PDFドキュメントは英語版と日本語訳版の両方が混在しています。
※「Japanese」というキーワードを入力すると、日本語訳版だけが表示されます。
- AB-147Simultaneous trace determination of seven metals in «electronic grade» materials using stripping voltammetry
The metals Cd, Co, Cu, Fe, Ni, Pb, and Zn are determined in the sub-ppb range (limit of detection 0.05 µg/L) by means of stripping voltammetry. The DP-ASV method is used for Cd, Cu, Pb, and Zn whereas Co, Ni, and Fe are determined by means of the DP-CSV method (dimethylglyoxime or catechol complexes).Use of the VA Processor and the sample changer allows automatic determination of the above metal ions in one solution. The method has been specially developed for trace analysis in the manufacture of semiconductor chips based on silicon. It can naturally also be employed successfully in environmental analysis.
- AB-176アノードストリッピングボルタンメトリーによる鉛および錫の測定
多くの電解質において鉛と錫のピーク電位はあまりにも近接しているため、電圧電流法での測定は不可能です。特に片方の金属が過度に存在している場合に、その困難は生じます。メソッド1では、Pb および Sn の測定について説明しています。アノードストリッピングボルタンメトリー (ASV) は、臭化セチルトリメチルアンモニウムを添加した上で用いられます。このメソッドは以下の場合に使用されます:• 主に Pb について調査したいとき• Pbが過度に存在しているとき• Sn/Pb の比率が200:1を超えないときメソッド1に従って、Sn とPb は、濃度差が高過ぎず、Cd が含まれていなければ、同時に測定することができます。メソッド2は微量の Sn と Pb が検出されている、または、TI および/または Cd イオンが存在する場合に適用されます。このメソッドは、メチレンブルーの添加されたシュウ酸緩衝液において DPASV も使用します。
- AB-177石油製品中の臭素価および臭素指数の自動測定
臭素価および臭素指数は、石油製品中の脂肪族 C = C二重結合の測定において重要な品質管理パラメータです。いずれの指標からも、臭素と反応する物質の含有量に関する情報を知ることができます。両指標の違いは、臭素価はサンプル100gあたりの臭素の消費をグラムで、臭素指数は100gあたりの消費量をミリグラムで示すことです。このApplication Bulletinでは、ASTM D1159、ISO 3839、BS2000-130、IP 130、GB/T 11135 および DIN-51774-1に準じた臭素価の測定について説明されています。脂肪族炭化水素のための臭素指数測定は、ASTM D2710、IP 299、GB/T 11136 および DIN 51774-2に準じて説明されています。芳香族炭化水素のためには、臭素指数の測定はASTM D5776 および SH/T 1767に準じて説明されています。UOP 304は、その滴定溶媒に塩化第二水銀が含まれるため、臭素価または臭素指数の測定には推奨されません。
- AB-178完全自動の水質分析
電気伝導度、pH値、p値およびm値 (アルカリ度)、塩化物含有量、カルシウムおよびマグネシウム硬度、総硬度、ならびにフッ化物含有量などといったか物理的および化学的パラメータの測定は、水質評価において必要不可欠です。この bulletin では、上記のパラメータを、一度の分析実行でいかに測定できるかが説明されています。水質分析においてさらに重要なパラメータは、過マンガン酸塩指数 (PMI) および化学的酸素要求量 (COD) です。そのため、この Bulletin では、EN ISO 8467に準じたPMIの完全自動測定、ならびにDIN 38409-44に準じたCODの測定についても説明しています。
- AB-179Polarographic determination of maleic and fumaric acid alone or in mixtures
Maleic and fumaric acid can be reduced electrochemically to succinic acid. In acidic solutions a differentiation of the two acids is not possible since both are reduced at the same potential. On the other hand, separation at pH 7.8...8.0 is easily possible since fumaric acid is now more difficult to reduce at the lower proton concentration (as a result of cis-trans isomerism) than maleic acid.
- AB-180Automatic determination of the formol number in fruit and vegetable juices
The formol number represents a further parameter for the characterization of fruit and vegetable juices. As this is merely an index (the formalin number does not deal with the molecular size, nor with the quantity of amino acids), the conditions of the titration can be adapted to meet practical needs. This concerns mainly the pH value of the endpoint of the SET titration (pH = 8.5, pH = 9.0, pH = 9.2, etc.).
- AB-181Automatic potentiometric titration of aluminum and magnesium in the same solution
Mixtures of aluminum and magnesium ions can be analyzed automatically using potentiometric titration. The excess DCTA is back-titrated with copper(II) sulfate solution after the addition of 1,2-diaminocyclohexanetetraacetic acid (DCTA) and complex formation. The ion-selective copper electrode is used here as the indicator electrode. First, the aluminum is determined in acidic solution and then the magnesium in alkali solution.
- AB-186Determination of aluminum in water samples by adsorptive voltammetry
This Bulletin describes the voltammetric determination of aluminum in water samples down to a concentration of 1 μg/L. An aluminum complex is formed with alizarin red S (DASA) and enriched at the HMDE. The following determination employs differential pulse adsorptive stripping voltammetry (DP-AdSV). Disturbing Zn ions are eliminated by addition of CaEDTA.
- AB-188pH measurement technique
This Bulletin, using practical examples, indicates how the user can achieve optimum pH measurements. As this Bulletin is intended for actual practice, the fundamentals - which can be found in numerous books and publications - are treated only briefly.
- AB-190ポーラログラフィーによるテレフタル酸中の4-カルボキシベンズアルデヒドの測定
4-カルボキシベンズアルデヒド (以下4-CBA) は、アンモニア性溶液において滴下水銀電極 (DME) で直接還元することができます。ごく簡単なサンプル前処理後、ポーラログラフィーによってppmを下回る範囲まで、テレフタル酸中の4-CBA濃度を迅速かつ正確に測定することが可能です。
- AB-191ポーラログラフィーによるシステインおよびシスチンの同時測定
生体サンプル (例えば牛乳や羊毛など) の劣化後は、しばしばシステイン/シスチン比率の確認が重要です。このApplication Bulletinでは、2種類のアミノ酸のポーラログラフィーによる同時測定について説明しています。この測定は DME で過塩素酸溶液にて実施されます。タンパク質含有量の高いサンプルでは、測定をアルカリ性溶液で行う必要性があります。
- AB-192ポーラログラフィーおよびカソードストリッピングボルタンメトリーによる低いmg/Lおよびµg/L範囲におけるチオ尿素の測定
チオ尿素は、水銀と共に不溶性の高い化合物を形成します。その結果生じる陽極波はチオ尿素のポーラログラフィー測定に用いられます。ごく少量 (µg/L) の分析にはカソードストリッピングボルタンメトリー (CSV) が用いられます。示差パルス測定モードはいずれのケースにも用いられます。
- AB-195Titrimetric determination of free boric acid and tetrafluoroboric acid in nickel plating baths
This Bulletin describes the simultaneous potentiometric titration of free boric acid and free tetrafluoroboric acid in nickel plating baths. After addition of mannitol, the formed mannitol complexes are titrated with sodium hydroxide solution. The determination is carried out directly in the plating bath sample; nickel and other metal ions do not interfere.
- AB-196ポーラログラフィーによるホルムアルデヒドの測定
ホルムアルデヒドは DME で還元的に測定することが可能です。サンプル組成によって、サンプルでホルムアルデヒドを直接測定できるかどうかは異なります。干渉が生じる場合、吸収、抽出、または蒸留などのサンプル前処理が必要となります。ここでは2つのメソッドについて説明します。1つ目のメソッドでは、ホルムアルデヒドはアルカリ性溶液にて直接還元されます。高濃度のアルカリ度またはアルカリ土類金属は干渉します。このような場合は、2つ目のメソッドを使用することができます。ホルムアルデヒドは、酸性溶液にてポーラログラフィーによって測定することのできるヒドラゾンを形成するヒドラジンを用いて誘導体化されます。
- AB-199ポーラログラフィーによる硫化物および亜硫酸塩の測定
硫化物および亜硫酸塩は、全く問題なくポーラログラフィーによって測定することができます。硫化物ではポーラログラフィーはアルカリ性溶液にて実施され、亜硫酸塩では弱酸性の一次溶液にて実施されます。このメソッドは医薬品 (輸液)、廃水や排ガス水、写真現像液などの分析に適しています。
- AB-200プラスチック製造のための原材料の酸価、ヒドロキシル価、およびイソシアネート価 - 様々な規格に準じた自動電位差滴定による測定
ポリウレタンは、最も一般的によく用いられるプラスチックの1種です。これは原料ポリオールのイソシアネートとの反応によって製造されます。出発物質に応じて、幅広い種類のプラスチックを得ることができます。酸価、ヒドロキシル価、およびイソシアネート含有量の測定は、プラスチックの原材料の分析において重要な役割を担います。ポリオール原材料の酸価は、バッチ間の均一性を保証するため、品質管理においてよく用いられています。さらに、これは真のヒドロキシル価を計算するための補正因子として用いられます。このApplication Bulletinでは、ASTM D4662 および ASTM D7253に準じた酸価の測定について説明されています。ポリウレタンの原料の1つがポリオールです。ポリオールには、複数のヒドロキシル基が含まれています。それゆえ、原料のヒドロキシル価は存在するポリオールの量に直接相関するので、重要な品質管理パラメータです。このApplication Bulletinでは、ASTM E1899 および DIN 53240-3に準じたヒドロキシル価の測定について説明されています。ポリオールはイソシアネートと化学量論的に反応するため、イソシアネート含有量を知ることは、ポリウレタンの製造において重要な品質パラメータです。この文書では、EN ISO 14896 メソッド A、ASTM D5155 メソッド A ならびに ASTM D2572 に準じた測定について説明されています。
- AB-204Oxidation stability of oils and fats – Rancimat method
This document outlines Rancimat testing for both liquid and solid food samples, including direct and PEG methods, for oxidation stability QC in the food industry.
- AB-205Thermostability of PVC and other chlorine-containing polymers
This Application Bulletin describes the determination of the thermostability of PVC in accordance with ISO 182 Part 3 using the dehydrochlorination method with the 895 Professional PVC Thermomat. The instrument permits fully automatic determination of the stability time. The test is suitable for monitoring the manufacture and processing of PVC products manufactured in the injection molding process, for their final clearance, characterization and for the comparison of PVC products and for testing the effectiveness of heat stabilizers.
- AB-206Titer determination in potentiometry
This Bulletin provides an overview of the potentiometric titer determination of current titrants. Many publications only describe methods with color indicators. However, the titration conditions chosen for the titer determination should resemble those used for the actual analysis as closely as possible. The tables contain suitable titrimetric standard substances and electrodes for selected titrants as well as additional information. Following this, an example is given to show what an SOP for a titer determination could look like.
- AB-207カーボンRDEを用いたアノードストリッピングボルタンメトリーによる銀の測定
このApplication Bulletinでは、グラッシーカーボンチップ (GC) または超微量グラファイトチップを用いた回転ディスク電極 (RDE) における Ag のストリッピング分析について説明しています。通常操作では銀の測定限界はおよそ 10 μg/L ですが、作業を慎重に行うことで 5 μg/L まで達することも可能です。適切な分解後は、有機成分の含有比率が比較的高いサンプル (例えばワインや食料品など) における銀の測定も可能です。このメソッドは、主に水のサンプル (井戸、地下水および廃水、写真産業における脱銀液) のために開発されたものです。
- AB-209絶縁油、炭化水素、ならびにその製品に含まれる水分 - カール フィッシャー滴定による正確かつ信頼性の高い測定
カールフィッシャー電量滴定のみが、低水分を充分な精度で測定することができます。このApplication Bulletinでは、ASTM D6304、ASTM E1064、ASTM D1533、ASTM D3401、ASTM D4928、EN IEC 60814、EN ISO 12937、ISO 10337、DIN 51777 および GB/T 11146に準じた直接測定について説明されています。Ovenの技術は、ASTM D6304、EN IEC 60814 および DIN 51777に準じて説明されています。
- AB-211Sample preparation for ion chromatography
The sample preparation for ion chromatography is divided into steps which should generally be implemented to preserve the column and into steps which should be performed to obtain an improved chromatogram. The goal is to have the test substance in ionic form in solution without the presence of interfering substances.
- AB-213ポーラログラフィーによるニコチン酸アミドの測定
このApplication Bulletinでは、ビタミンB群の1つであるニコチン酸アミド (ビタミンPP) の測定について説明しています。溶液 (フルーツジュースなど)、ビタミンカプセルおよびマルチビタミン剤における測定のための手引きが示されています。測定の直線性の範囲も指定されています。ニコチン酸アミドの検出限界はおよそ 50 μg/L です。
- AB-215ポーラログラフィーによる葉酸の測定
このApplication Bulletinでは、ビタミンB群の1つであり、ビタミンB9またはBCとして知られる葉酸の、ポーラログラフィーによる測定について説明されています。溶液 (フルーツジュースなど)、ビタミンカプセルおよびマルチビタミン剤における測定のための手引きが示されています。測定の線形範囲も指定されています。葉酸の検出限界はおよそ 75 μg/L です。
- AB-218ポーラログラフィーによるチアミン (ビタミンB1) の測定
このApplication Bulletinでは、チアミン (ビタミンB1) のポーラログラフィーによる測定について説明しています。この手順により、モノビタミンの製剤における分析が可能となります。測定の線形範囲も示されています。チアミンの検出限界はおよそ 50 µg/L です。
- AB-219ポーラログラフィーによるリボフラビン (ビタミンB2) の測定
このApplication Bulletinでは、リボフラビン (ビタミンB ) のポーラログラフィーによる測定について説明されています。この手順により、モノビタミンの製剤における分析が可能となります。測定限界はおよそ 100 μg/L です。
- AB-220吸着ストリッピングボルタンメトリーによる超微量域の白金およびロジウムの測定
このApplication Bulletinは…
- AB-221水質分析の標準的な方法
この会報は、水分析の分野からの標準的な方法の調査を提供します。また、それぞれの決定に必要な分析機器と、対応するメトロームアプリケーション速報およびアプリケーションノートへの参照もあります。次のパラメータが処理されます:電気伝導率、pH値、フッ化物、アンモニウムおよびケルダール窒素、イオンクロマトグラフィーによる陰イオンおよび陽イオン、ボルタンメトリーによる重金属、化学酸素需要(COD)、水の硬度、遊離塩素も他のいくつかの水の成分として。
- AB-223Fully automated determination of uranium
This Bulletin describes the fully automated determination of uranium according to the method of Davies and Gray: Uranium(VI) is reduced in concentrated phosphoric acid solution with iron(II) to form Uranium(IV). With molybdenum as a catalyst, the excess iron(II) is oxidized with nitric acid. The nitrous acid that is formed is destroyed with sulfamic acid before uranium(IV) is titrated with a potassium dichromate solution in the presence of a vanadium catalyst.
- AB-224ポーラログラフィーによるピドリキシン (ビタミンB6) の測定
このApplication Bulletinでは、ピドリキシン (ビタミンB6) のポーラログラフィーによる測定について説明しています。ここで示されているメソッドにより、モノビタミンおよびいくつかのマルチビタミン製剤における測定が可能となります。分析の線形範囲も指定されています。ピドリキシンHCIの検出限界はおよそ 100 µg/L です。
- AB-225Simple wine analysis
The Bulletin describes the determination of the following parameters in wine: pH value, total titratable acid, free sulfurous acid, total sulfurous acid as well as ascorbic acid (vitamin C) and other reductones.
- AB-226Determination of arsenic by stripping voltammetry at the rotating gold electrode
This Bulletin describes the determination of arsenic by anodic stripping voltammetry (ASV) at the rotating gold electrode. A determination limit of 0.5 μg/L can be achieved with 10 mL sample solution. A differentiation between the As(III) concentration and the total arsenic concentration can be made by appropriate selection of the deposition potential. The analyses are performed with a special gold electrode whose active surface is located laterally; c(HCl) = 5 mol/L is used as supporting electrolyte. For the determination of the total arsenic content, As(III) and As(V) are reduced at -1200 mV by nascent hydrogen to As0, which is preconcentrated on the electrode surface. If the deposition is carried out at -200 mV then only As(III) is reduced; this allows the differentiation between total arsenic and As(III). During the subsequent voltammetric determination the preconcentrated As0 is again oxidized to As(III).
- AB-230Potentiometric determination of nonionic surfactants based on polyoxyethylene adducts with the NIO electrode
The titrimetric determination of nonionic surfactants on the basis of polyoxyethylene adducts (POE adducts) is described in the Bulletin. The basis for the determination is the transfer of the nonionic surfactant into a pseudo-cation compound and its precipitation titration with sodium tetraphenylborate (Na-TPB). The NIO electrode is used for the indication of the potentiometric titration. This Bulletin describes determinations in raw products, formulations and wastewater and draws attention to special features, possibilities, limits and disruptions.
- AB-231DIN 38406-16に則したアノードおよび吸着ストリッピングボルタンメトリーによる、水サンプルに含まれる亜鉛、カドミウム、鉛、銅、タリウム、ニッケル、およびコバルトの測定
DIN 38406 Part 16 を条件とした標準メソッドでは、飲料水、地下水、地表水、および降水 (雨水など) に含まれるZn、Cd、Pb、Cu、Tl、Ni、およびCoの測定について説明しています。水サンプル中に含まれる有機物質は電圧電流法による測定に強い干渉を与え得るため、過酸化水素を用いたUV分解による前処理が必要となります。この分解により、ブランク値の導入なしですべての有機物質を確実に除去することができます。これらのメソッドはもちろん、例えばシリコンベースの半導体チップの製造における微量分析など、他の物質の微量分析にも応用することができます。Zn、Cd、Pb、Cu、およびTlはアノードストリッピングボルタンメトリー (ASV) を用いてHMDEで測定され、NiおよびCoは吸着ストリッピングボルタンメトリー (AdSV) を用いて測定されます。
- AB-232Determination of antioxidant activity in accordance with the Rancimat method
The effectiveness of antioxidants can be expressed as antioxidant activity. It can be readily determined using the Rancimat method. This is accomplished by first determining the induction time of a mixture made up of hog fat and the antioxidant to be investigated and then by determining the corresponding time for hog fat alone. The quotient expresses the efficiency of the respective antioxidant and is referred to as the antioxidant activity index (AAI).This Application describes the determination of the antioxidant activity index of five common antioxidants.
- AB-233Potentiometric determination of anionic and cationic surfactants with surfactant electrodes
Anionic surfactants can be titrated with cationic surfactants and vice-versa. The Bulletin describes a multitude of substances that can be determined in this fashion and specifies the respective working conditions and parameters. In contrast to the classic two-phase titration in accordance with Epton, the titration with the anionic and cationic surfactants electrodes can be performed without chloroform. Furthermore, the equivalence point of the titration is difficult to determine in some cases with the Epton method and the titration cannot be automated.In many cases, a surfactant ISE is a remedy that is both environmentally friendly and suitable here. It was developed specially for application with potentiometrically indicated surfactant determinations.
- AB-235Potentiometric titration of calcium (magnesium) in dairy products
This Bulletin describes a simple method for the determination of the calcium content in dairy products. The use of CuEGTA and the ion-selective copper electrode (Cu ISE) as indicator electrode allows the determination to be performed without time-consuming sample preparation. If the complexing agent EDTA is used as titrant instead of EGTA, the sum of calcium and magnesium is obtained. The magnesium content can then be calculated from the difference between the results of the two titrations.
- AB-237Determination of the stability index of solid foods with the Rancimat method
Determination of the oxidation stability of foods with a low fat content is a challenge. As an alternative, the oxidation stability can be specified indirectly. To accomplish this, a determination is made as to the extent that a sample that has been mixed with a fat as a standard solution, e.g., hog fat, will change the oxidation stability of that standard solution. This is accomplished by first determining the induction time of the mixture made up of hog fat and the sample and then by determining the corresponding time for the lard alone. The quotient is referred to as the stability index (SI).
- AB-241Determination of cadmium and lead by anodic stripping voltammetry at a mercury film electrode
This Application Bulletin describes the determination of cadmium and lead at a mercury film electrode (MFE) by anodic stripping voltammetry (ASV). The mercury film is plated ex situ on a glassy carbon electrode and can be used for up to one day. With a deposition time of 30 s, the limit of detection is ß(Cd2+) = 0.02 µg/L and ß(Pb2+) = 0.05 µg/L. The linear working range for both elements goes up to approx. 50 μg/L using the same deposition time.
- AB-242超微量グラファイトRDEを用いたアノードストリッピングボルタンメトリーによるタングステンの測定
ここで説明されているメソッドにより、0.2~50 µg/L (ppb) 範囲の微量の W(VI) を測定することが可能となります。サンプル (天然水など) に含まれる微量の有機化合物は干渉します。それらはUV分解によって除去しなければなりません (705 UV Digester など)。100 mg/L までの濃度のFe(III) による干渉は、アスコルビン酸を用いた Fe(lI) への還元によって除去します。もしサンプル中の Cu(II) の量が係数200またはそれ以上で W(VI) の量を上回る場合、Cuイオンはチオ尿素によって固定されなければなりません。さらに、Cu(II) 濃度が 5 mg/L を超えてはなりません。測定はDPモードにおいて吸着ストリッピング分析によって実施されます。
- AB-243超微量グラファイトRDEを用いた吸着ストリッピングボルタンメトリーによるクロムの測定
このメソッドでは、1~250 μg/L の間の範囲の微量 Cr の測定について説明しています。このメソッドは超微量グラファイト回転ディスク電極 (RDE) におけるCr(lll)-ジフェニルカルバゾナト錯体の吸着をベースとしています。サンプル (天然水など) に含まれる有機化合物は強い干渉効果を有します。そのため、それらはUV分解などによって除去しなければなりません。測定はDC (直流) 測定モードで吸着ストリッピングボルタンメトリーによって実施されます。窒素パージは不要です。測定は、高塩濃度溶液においても良く機能します。
- AB-249DIN EN ISO 7393-1 および APHA 4500-Cl に基づく遊離残留塩素の測定
塩素は、消毒目的で飲料水にしばしば添加されます。塩素の反応性および濃度によっては、その際に毒性のある消毒副生成物 (DBP) が放出されることがあります。そのため、飲料水の塩素濃度を厳しく管理する必要があります。この Application Bulletin では、DIN EN ISO 7939-1、APHA 4500-Cl メソッド B、および APHA 4500-Cl メソッド I の3つの標準メソッドに従ってどのように塩素濃度を測定するかが示されています。
- AB-250Polarographic determination of diazepam in body fluids and pharmaceutical preparations
Diazepam belongs to the 1,4-benzodiazepine group of compounds, which are used for medical purposes as tranquilizers and antidepressants. This Bulletin describes the determination of diazepam in tablets and body fluids (blood, serum, urine) by means of differential pulse polarography. If a Britton-Robinson buffer pH = 2.8 with a methanol volume fraction of 20% is used as the supporting electrolyte then a pronounced reduction peak is obtained at -0.73 V; this allows diazepam concentrations even below 0.05 µg/mL to be determined in blood. The necessary sample preparation steps are also dealt with in this Bulletin.
- AB-251Polarographic determination of cinchocaine (dibucaine) in pharmaceutical preparations
Cinchocaine (dibucaine) is used in the form of ointments or injection solutions as a local anaesthetic. Its base is soluble in diethyl ether; its hydrochloride, on the other hand, is insoluble in diethyl ether but easily soluble in water. This Bulletin describes the determination of cinchocaine in ointments, creams and injection solutions by means of differential pulse polarography. An acetate buffer pH = 4.8 is used as the supporting electrolyte. The limit of quantitation and the linear working range of the method are given. The necessary sample preparation steps are also dealt with in this Bulletin.
- AB-254水銀膜電極でのアノードストリッピングボルタンメトリーによる亜鉛、カドミウム、および鉛の測定
このApplication Bulletinでは、水銀膜電極 (MFE) での亜鉛の測定について説明しています。亜鉛は、カドミウムおよび鉛と同時に測定することもできます。MFE での銅の測定はできません。水銀膜は GC 電極上にエクスシトゥ(ex-situ)でめっきされており、半日から1日の間使用することができます。亜鉛は、アノードストリッピングボルタンメトリー (ASV) によって水銀膜電極で測定することができます。多くのサンプルに自然に含まれている銅の存在は、金属間化合物形成の理由から、測定に影響を及ぼします。その結果、測定された亜鉛濃度が低過ぎることになります。ガリウムと銅の金属間化合物は亜鉛と銅の化合物より安定性が高いため、ガリウムを添加することで、干渉をある程度取り除くことができます。蒸着時間 10 秒の場合、検出限界は β(Zn2+) = 0.15 μg/L です。線状の稼動範囲はおよそ 300 μg/L までになります。蒸着時間 10 秒の場合、メソッドは亜鉛含有量 10 μg/L から 150 μg/L のサンプルに適しています。濃度の比較的低いサンプルでは、蒸着時間が例えば 30 秒まで増加した場合に、より信頼度の高い結果が得られます。濃度のより高いサンプルは希釈しなければなりません。
- AB-264Titrimetric methods for the determination of betains
The two potentiometric titration methods described here allow the determination of the content of commercial betaine solutions. Neither method is suitable for determining the betaine content of formulations. The possibilities and limits of both methods are described and distinctive features and possible sources of interference are mentioned. The Bulletin explains the most important theoretical principles and is intended to help users to develop their own product-specific titration methods.
- AB-265Hamilton PRP-X100 IC anion column (6.1005.000)
This Bulletin describes the determination by ion chromatography of anions, particularly fluoride, chloride, nitrite, bromide, nitrate, and sulfate using the Hamilton PRPX100 IC anion column without chemical suppression.
- AB-266吸着ストリッピングボルタンメトリーによるチタンの測定
このApplication Bulletinでは、マンデル酸を錯化剤として用いた吸着ストリッピングボルタンメトリー (AdSV) によるチタンの測定について説明しています。このメソッドは、チタン濃度が重要とされる地下水、飲料水、海水、地表水、および冷却水の分析に適しています。このメソッドはもちろん、他のマトリックスの微量分析にも用いることができます。検出限界はおよそ 0.5 µg/L です。
- AB-268界面活性剤および医薬品の電位差滴定 - 概要
このBulletinでは、電位差滴定を用いて測定できる数多くの界面活性剤および医薬品の概要をご覧いただけます。Metrohmは滴定の終点を示す5つの異なる界面活性剤電極、すなわちイオン界面活性剤電極、High Sense、Surfactrode Resistant、Surfactrode Refill、NIO界面活性剤電極を提供しています。それぞれの滴定試薬の製造およびそれらの試薬ファクター測定については、詳細に説明されています。 それに加え、このBulletinには、界面活性剤および医薬品分析の分野からの、170を超える数のテスト済みアプリケーションを表形式にした概要が含まれています。このガイドラインは、お客様を確実に目的地までご案内します: どの界面活性剤電極、および、どの滴定試薬がお客様の製品に最も適しているか、この表によって、ひと目でご覧いただけます。
- AB-269Potentiometric determination of ionic surfactant through two-phase titration with the Surfactrode
On the basis of a multitude of practical examples, this Bulletin describes the potentiometric two-phase titration of ionic surfactants in raw materials and many other formulations.Two surfactant electrodes – the Surfactrode Resistant and the Surfactrode Refill – make it possible to perform this type of surfactant titration, analogous to the classic "Epton titration", with a high degree of automation. The achieved results correlate very well with those of Epton titration. The toxic, carcinogenic and environmentally hazardous chloroform can be replaced by other solvents such as methyl iosbutyl ketone or n-hexane.