Applications
- WP-046Overcoming the aqueous limitation at NIR Spectroelectrochemistry
NIR spectroscopy has been traditionally limited due to the water absorption in this spectral range. In this way, the well-known water restriction has limited the development of new applications for NIR spectroelectrochemistry. In this work, several interesting alternatives are proposed in order to minimize or even to remove the aqueous contribution in this spectral range.
- WP-047Optimizing the chlor-alkali process through online chemical analysis
This White Paper explores the critical role of advanced online and inline process analysis in brine chlorine operations, emphasizing their advantages over traditional methods.
- WP-048Utilizing online chemical analysis to optimize propylene oxide production
Propylene oxide (PO) is a major industrial product used in assorted industrial applications, mainly for the production of polyols (the building blocks for polyurethane plastics). Several production methods exist, with and without co-products. This white paper lays out opportunities to optimize PO production for safer and more efficient processes, higher quality products, and substantial time savings by using online process analysis instead of laboratory measurements.
- WP-049Your IC results are only as good as your sample vials
Polymeric sample vials are frequently contaminated with leachable organic or inorganic ions, which originate from the production process or the raw material. These substances can falsify measurement results. The study at hand compares the leaching properties of several vial types from different manufacturers, showing considerable variations in quality and proving the importance of the right choice of vials for ion chromatography (IC). This white paper also provides recommendations and precautions to further reduce leachable contaminants for IC trace analysis.
- WP-050Manual vs. Automated Titration: Benefits and Advantages to Switching
Titration is one of the most commonly used analytical methods. Manual, semiautomated, and fully automated titrationsare well-known options and are examined in detail in several academic studies. This white paper summarizes the advantages and benefits of automated titration in comparison to manual titration. The increase in accuracy and precision of measurements as well as significant time and cost savings are discussed.
- WP-051Automated CVS method development and optimization of multicomponent plating baths
For the past three decades, Cyclic Voltammetric Stripping (CVS) has been the standard practice for analyzing organic additives in electroplating copper baths in the circuit board and wafer plating industries. The variations in the compositions of such baths have created a need for more optimized method development routines. New advancements in the hardware and software protocols for CVS have simplified the overall process of method optimization to a great extent. In this study, the process of method optimization is discussed in conjunction with these protocols.
- WP-052A Guide to Li-ion Battery Research and Development
The commercialization of Li-ion batteries in 1991 was the culmination of in-depth R&D conducted by scientists and engineers around the globe over the preceding few decades. Further development of Li-ion batteries and alternative rechargeable batteries has continued until today. As the world is rapidly moving towards a new era defined by green technologies, more practical and accurate R&D is required in order to meet the increasing demands for energy storage systems, specifically from the automotive industry. This white paper presents the basics of the Li-ion battery technology and guides the reader through the relevant techniques and terminologies in Li-ion battery research.
- WP-053Determination of Acid Number (AN) with Titration and NIR Spectroscopy
The acid number (AN) is a measure for the quality of oils and their potential to enhance corrosion. When analyzing fresh, unused oils, the AN is used to ensure the specified quality from the manufacturer, whereas for used oils the AN is determined to observe its increase until a critical level is reached. Although it is generally assumed that the AN correlates to the corrosive potential of the oil, this is not exactly correct, as it is the change of the AN value which indicates this issue. Therefore it is necessary to determine the AN on a regular basis.Several standards already exist to determine AN via titration methods, however it is also possible to measure this parameter via spectroscopic (NIRS) methodology. No matter which technique you choose, Metrohm has you covered with high-performance instruments suitable for these published norms.
- WP-054Boost efficiency in the QC laboratory: How NIRS helps reduce costs up to 90%
Underestimation of quality control (QC) processes is one of the major factors leading to internal and external product failure, which have been reported to cause a loss of turnover between 10–30%. As a result, many different norms are put in place to support manufacturers with their QC process. However, time to result and the associated costs for chemicals can be quite excessive, leading many companies to implement near-infrared spectroscopy (NIRS) in their QC process. This paper illustrates the potential of NIRS and displays cost saving potentials up to 90%.
- WP-055Corrosion Best Practice – Creating Pipe-flow Conditions Using a Rotating Cylinder Electrode
Electrochemical measurements utilizing a rotating cylinder electrode (RCE) are widely used in industrial corrosion applications when simulation of realistic pipe conditions are necessary in a lab environment. This white paper allows further insight into the particularities and parameters which govern the electrochemical measurements, in particular measurements performed in turbulent flow conditions, and shows a complete picture of the best practice use of this technique. The annexes provide an overview and short explanation of the parameters and laws specific to the fluid behavior in electrochemical cells with RCE.