- AN-CS-002Ammonium – Sequential suppression with linear calibration
Ammonium determination after sequential suppression frequently exhibits non-linear calibration curves. The reason for this is the ammonium hydroxide that arises and that is present in a form characterized by low dissociation. The sequential cation suppression forms the more highly dissociated ammonium hydrogen carbonate. Ammonium and the other standard cations exhibit linear calibration curves (R > 0.9997).
- AN-CS-008Determination of dimethylamine in meropenem using sequential suppression
Meropenem is a beta-lactam antibiotic that is classed among the carbapenems; it suppresses murein biosynthesis and thus the buildup of the bacterial cell wall. Dimethylamine is an important precursor in meropenem synthesis and must therefore be monitored as an impurity. Detection is performed on the Metrosep C Supp 1 - 250/4 column with subsequent conductivity detection after sequential suppression.
- AN-CS-005Determination of tetrabutylammonium in atorvastatin using sequential suppression
Atorvastatin is a medication that is used for reducing cholesterol levels. A sensitive and reliable method for TBA detection is required, given that trace amounts of tetrabutylammonium (TBA) are to be found in the presence of atorvastatin and its derivatives. One such method is ion chromatographic separation on the Metrosep C Supp 1 - 250/4.0 with subsequent conductivity detection and sequential suppression.
- AN-CS-009Leaching tests for sample vials in cation trace analysis with sequential suppression
Sequential suppression in cation chromatography significantly improves detection limits. The determination of the blank value of the sample vial being used is thus essential for being able to achieve such low detection limits. The leaching tests of various sample vials proceed with the intelligent Preconcentration Technique with Matrix Elimination on the Metrosep C Supp 1 - 250/4.0 column with conductivity detection following sequential suppression. The 50 mL Corning® Cell Culture Flasks from Sigma-Aldrich (CLS430168) exhibit the lowest blank values.
- AN-CS-019Trace ammonium and trimethyl-amine in 30% hydrogen peroxide applying sequential suppression
Determination of trace levels of cations and amines in hydrogen peroxide is important in quality determination of high-grade semiconductor chemicals. In particular, some manufactures look for 1 ppb trimethylamine or less in hydrogen peroxide samples. Ion chromatography after MiPCT-ME* with conductivity detection after sequential cation suppression is applied.
- AN-CS-006Aliphatic amines and ethanol amines in addition to standard cations by sequential suppression
This Application Note shows the selectivity of the Metrosep C Supp 1 - 250/4.0 column for alkyl and ethanol amines in addition to standard cations under isocratic conditions. Quantification takes place using conductivity detection following sequential suppression.
- AN-CS-007Lithium in addition to other cations in seepage water from minerals through sequential suppression
With the advent of electric automobiles, the demand for lithium batteries and with it the demand for lithium material will increase sharply. Brine lakes and hard silicate minerals are numbered among the most important sources of lithium. This Application Note addresses cation determination in seepage water from lithium minerals. Alkali and earth alkali metals are separated in the lithium digestions on the Metrosep C Supp 1 - 250/4.0 column, with subsequent conductivity detection after sequential suppression.
- AN-CS-003Biogenic amines in addition to standard cations with conductivity detection following sequential suppression and Dose-in Gradient
The concentrations of toxic, biogenic amines in foods, particularly in fish and wine, are an important quality characteristic. The present Application Note shows the separation of putrescine, cadaverine and histamine in addition to the standard cations. Separation takes place on a Metrosep C Supp 1 - 250/4.0 with Dose-in Gradient; quantification via conductivity detection following sequential suppression.
- 8.000.6076Sequential suppression for conductivity detection in ion chromatography
The poster describes how different suppressors (MSM and MCS) work and mentions possible applications.
- AN-CS-001Reproducibility of 10 µg/L injections after cation suppression
Cation chromatography with sequential suppression enables the determination of cations in their hydrogen carbonate form. The eluent – usually nitric acid – is converted into carbonic acid. Following its decomposition into carbon dioxide and water, the former is continuously removed by the CO2 suppressor. The reduction of baseline noise thus achieved permits the lowering of the detection limits and improves reproducibility, even at very low cation concentrations. This Note shows the reproducibilities determined for cation concentrations of 10 µg/L.
- AN-CS-016Metrosep C Supp 2 - 150/4.0: Amines applying suppressed cation chromatography
The Metrosep C Supp 2 column family is polystyrene/divinylbenzene based and therefore sequential cation suppression may be applied. This AN shows the separation and detection of different amines on the 150 mm version of the column with subsequent conductivity detection after sequential cation suppression.
- AN-S-369Phosphite and phosphate in Pamidronate suppressed conductivity detection
Pamidronate is applied to treat osteoporosis by strengthening the bones. It is a bisphosphonate containing a primary amine group. Phosphite and phosphate are related compounds, which need to be quantified. USP requires the use of formic acid eluent with refractive index detection. But a standard IC procedure offers an alternative with better sensitivity. Phosphite and phosphate are analyzed with conductivity detection after sequential suppression.
- AN-S-394Anions in sodium hydrogen carbonate
Analysis of sodium hydrogen carbonate (also known as sodium bicarbonate) for anionic contaminants is critical due the large amount of CO2 formed during suppression. Even applying sequential suppression does not completely remove the interferences due to the carbonate peak. The introduction of Inline Neutralization applying the Sample Preparation Module (SPM) with subsequent CO2 removal with the MCS (Metrohm CO2 Suppressor) prior to the injection solves the problem. After this pretreatment, the sequentially suppressed sample is analyzed without issues.
- AB-359Installation Instruction for ProfIC Vario 1 Anion
This document describes the recommended equipment and the installation of a Professional IC Vario system with sequential suppression for anion or cation determination.
- AN-S-279Perchlorate and thiosulfate separated on a guard column
Determination of perchlorate and thiosulfate using anion chromatography with conductivity detection after sequential suppression.
- AN-S-246Sulfate in methanedisulfonic acid
Determination of sulfate in methanedisulfonic acid using anion chromatography with conductivity detection after sequential suppression.
- AN-S-271Fosetyl-aluminum in pesticide formulations
Determination of fosetyl-aluminum in a formulation using anion chromatography with conductivity detection after sequential suppression.
- AN-S-251Trace anions in concentrated phosphoric acid using two-dimensional ion chromatography
Determination of chloride, nitrate, and sulfate in 85% H3PO4 using two-dimensional anion chromatography with conductivity detection after sequential suppression.
- AN-S-273Fluoride, chloride, and nitrate in concentrated sulfuric acid
Determination of fluoride, chloride, and nitrate in concentrated sulfuric acid (96…98%) using anion chromatography with conductivity detection after sequential suppression.
- AN-S-282Phosphorus anions in a biocide
Determination of phosphate, HEDP (etidronic acid), and pyrophosphate in a biocide sample using anion chromatography with conductivity detection after sequential suppression.
- AN-S-268Halogens in petroleum coke after microwave combustion
Determination of fluoride, chloride, bromide, and iodide in petroleum coke after microwave combustion using anion chromatography with conductivity detection after sequential suppression.
- AN-S-252Standard anions and organic acids in Bayer liquor using inline matrix neutralization
Determination of fluoride, acetate, formate, chloride, sulfate, malonate, succinate, and oxalate in Bayer liquor using anion chromatography with conductivity detection after sequential suppression.
- AN-S-262Chloride, nitrate, and sulfate in cobalt acetate solution using Metrohm Inline Dilution
Determination of chloride, nitrate, and sulfate in cobalt acetate solution using anion chromatography with conductivity detection after sequential suppression using Metrohm Inline Dilution.
- AN-S-250Trace anions in tetramethylammonium hydroxide (TMAOH)
Determination of formate, chloride, nitrate, phosphate, and sulfate in 20% TMAOH using anion chromatography with conductivity detection after sequential suppression and inline matrix neutralization.
- AN-S-270Impurities in syringe filters – Anions
Determination of fluoride, acetate, formate, chloride, nitrite, nitrate, phosphate, and sulfate impurities in syringe filters using anion chromatography with conductivity detection after sequential suppression.
- AN-S-243Chloride, chlorate, and sulfate in soda lye (50% sodium hydroxide) using Metrohm Inline Sample Neutralization
Determination of chloride, chlorate, and sulfate in soda lye (50% sodium hydroxide) using anion chromatography with conductivity detection after sequential suppression and Metrohm Inline Neutralization.
- AN-S-264Inline eluent preparation for anion analysis
Long-term determination of standard anions with automatic inline eluent preparation applying Dosino and Level Control technology using anion chromatography with conductivity detection after sequential suppression.
- AN-U-047Nitrate and nitrite in cooling lubricant after inline dialysis
Determination of nitrite and nitrate in a cooling lubricant using anion chromatography with conductivity detection (see AN S-274) and subsequent UV detection after sequential suppression and Metrohm Inline Dialysis.
- AN-S-244Anions in a gasoline/bioethanol mixture using inline matrix elimination
Determination of fluoride, acetate, formate, nitrate, and sulfate in a gasoline/bioethanol mixture (85% gasoline, 15% ethanol) using anion chromatography with conductivity detection after sequential suppression and Metrohm Inline Matrix Elimination.
- AN-S-24914 anions in an industrial process water
Determination of fluoride, acetate, propionate, formate, butyrate, chloride, nitrite, bromide, nitrate, benzoate, phosphate, sulfate, malonate, and oxalate in an industrial process water using anion chromatography with conductivity detection after sequential suppression.
- AN-S-265Semi-continuous determination of anions in aerosol using PILS-IC
Determination of chloride, nitrite, nitrate, and sulfate in an ambient aerosol (PM2.5) using aerosol sampling with the PILS (Particle Into Liquid Sampler) and anion chromatography with conductivity detection after sequential suppression.
- AN-S-274Major anions in cooling lubricant after inline dialysis
Determination of chloride, nitrite, bromide, nitrate, phosphate, sulfite, sulfate, and oxalate in a cooling lubricant using anion chromatography with conductivity detection and subsequent UV detection (see AN-U-047) after sequential suppression and Metrohm Inline Dialysis.
- AN-S-267Anions in an E85 mixture (85% Ethanol and 15% gasoline) by means of Inline Matrix Elimination
Determination of fluoride, acetate, formate, chloride, nitrite, nitrate, phosphate and sulfate in an E85 mixture (85% ethanol and 15% gasoline) by means of anion chromatography with conductivity detection and sequential suppression. The Inline Matrix Elimination serves as sample preparation.
- AN-S-272Column-switching method for anions in water samples with two different analytical requirements
Determination of fluoride, chloride, nitrate, phosphate, and sulfate on a short column or the ions mentioned plus bromate and nitrite on a long column in water samples applying intelligent column-switching using anion chromatography with conductivity detection after sequential suppression.
- AN-S-278Anions in sodium tetraborate with Metrohm Inline Acidification, Metrohm Inline Matrix Elimination, and Metrohm Inline Calibration
Determination of fluoride, chloride, phosphate, and sulfate in sodium tetraborate using anion chromatography with conductivity detection after sequential suppression. Inline acidification is applied to convert tetraborate into boric acid which is not retained on the preconcentration column. Inline calibration minimizes the anion contamination.
- AN-CIC-002Halogens and sulfur in residual solvent using Combustion IC
Determination of fluoride, chloride, bromide and sulfate in residual solvent using combustion digestion as sample preparation and subsequent anion chromatography with conductivity detection following sequential suppression. The analysis is significant for use in dividing waste products into non-halogenated and halogenated solvents.Keyword: pyrohydrolysis
- AN-CIC-001Halogens in high-viscosity oils using Combustion IC
Determination of chloride and sulfate (non-quantified) in a high-viscosity oil sample using combustion digestion and subsequent anion chromatography with conductivity detection following sequential suppression.Keyword: pyrohydrolysis
- AN-S-370Chloride and sulfate impurities in potassium bicarbonate
Within the scope of the modernization of USP, chloride and sulfate are determined as impurities in potassium hydrogen carbonate (bicarbonate). USP41 monograph for potassium bicarbonate does not check for chloride and sulfate. Applying ion chromatography with conductivity detection after sequential suppression allows quantifying these impurities.
- AN-CS-018Metrosep C Supp 2 - 250/4.0: Cations in wastewater applying a Dose-in gradient
Cation analysis by IC in wastewater is a proven method. Limiting factor is often the Na/NH4 separation. High sodium concentrations may make ammonium determination impossible due to peak overlapping. The use of sequential suppression and a Dose-in gradient improve the Na/NH4 separation and enables determination of low ammonium concentrations.
- AN-CS-004Determination of choline in baby milk powder
Choline is important for the biosynthesis of numerous molecules, e.g., the neurotransmitter acetylcholine, and exists as an intermediate product in the human metabolism. Concentration determination takes place after microwave digestion. Separation is performed on the Metrosep C Supp 1 - 250/4.0 column following sequential suppression. Separation from the standard cations is outstanding.
- AN-CS-020Fast IC with Metrosep C Supp 2 - 100/4.0: Four cations in five minutes
The short Metrosep C Supp 2 - 100/4.0 allows applying a higher eluent flow. Together with a more concentrated eluent (7.0 instead of 5.0 mmol/L nitric acid) the run time of the four cations, sodium, potassium, magnesium, and calcium can be reduced to 5 minutes. Conductivity detection after sequential suppression is applied.
- AN-CS-011Cation traces in lithium hexafluorophosphate
Lithium hexafluorophosphate (LiPF6) is used as an electrolyte in rechargeable batteries. Its high solubility in non-polar solvents and its non-coordinating character in particular make lithium hexafluorophosphate the ideal salt for use in lithium-ion cells. This Application describes the determination of cation traces in LiPF6 with conductivity detection following sequential suppression.
- AN-S-333Chlorite and bromate in drinking water on a Microbore column
The determination of disinfection byproducts is essential for drinking water manufacturers. This Application Note shows the determination of chlorite and bromate in addition to the standard anions. In order to reduce eluent consumption, separation takes place on a Metrosep A Supp 5 - 250/2.0 Microbore column, followed by conductivity detection after sequential suppression.
- AN-U-074Determination of nitrite and nitrate in tobacco by ion chromatography with UV/VIS detection
Nitrite in tobacco facilitates the release of tobacco-specific nitrosamines. Most of these nitrosamines are carcinogenic. Therefore, the determination of nitrite in tobacco is required. This application describes the determination of nitrite and nitrate in acetic acid extracts of tobacco. The ion chromatographic separation is followed by UV/VIS detection after sequential suppression.
- AN-S-351Determination of glycolate and lactate in varnish remover
Glycolate and lactate have to be determined in a dual phase varnish remover. Analyzed is only the upper aqueous phase. The separation is achieved on a Metrosep A Supp 16 - 250/4.0 column. The eluent composition is adapted to get a sufficient separation of glycolate and lactate without interference by formate and acetate. Conductivity detection after sequential suppression is applied.
- AN-S-357Waste water from a waste water cleaning plant: Anion determination with a Metrosep A Supp 4 - 250/2.0
The microbore Metrosep A Supp 4 - 250/2.0 column is particularly suitable for the analysis of anions in critical samples. A waste water sample is being analyzed in the current application. The sample requires only one filtration prior to injection on the Metrosep A Supp 4 - 250/2.0. The anions are quantified with the application of conductivity detection following sequential suppression.
- AN-CS-012Determination of trimenthylamine and standard cations in 30% hydrogen peroxide (H2O2)
Hydrogen peroxide is available in different purity grades depending on its use. High purity H2O2 (electronic grade) requires very low contamination levels, e.g., less than 1 μg/L of trimethylamine (TMA). This application describes the determination of trimethylamine in a high-purity H2O2 solution (30%). Analysis is performed using Inline Preconcentration with Matrix Elimination (MiPCT-ME) applying conductivity detection after sequential cation suppression.
- AN-S-356Inorganic anions in monoethylene glycol from natural gas process
Monoethylene glycol is used for dehydration of the natural gas before liquefaction and has to be checked for its purity on routine basis. Inorganic anions and their corresponding acids are corrosive. Therefore, they have to be kept at minimum level. The separation is performed on a microbore Metrosep A Supp 16 - 250/2.0 column and quantified by conductivity detection after sequential suppression.
- AN-S-326Oxyhalides in addition to standard anions in swimming pool water
Swimming pool water needs to be thoroughly disinfected and this is often accomplished with ozonization. This process can generate harmful oxyhalides, the concentration of which must be monitored. Here the separation and determination of oxyhalides as well as standard anions are carried out using a column of the Metrosep A Supp 5 - 250/4.0 type. Quantification takes place using conductivity detection in accordance with sequential suppression.
- AN-CS-013Cations in deionized water and calculation of LOD and MDL of MiPCT
Trace cation analysis in high purity water (sub-μg/L range) requires cation chromatography after sequential suppression and intelligent Preconcentration Technique (MiPCT). Trace cations in deionized water (DI) are determined and the method detection limit (MDL according to US EPA) as well as the limit of detection (LOD = 3 x S/N) is calculated. MDL and LOD are very similar in the lowest ng/L range for this setup with 6 mL preconcentration volume.