Application Finder
- 8.000.6011Ion chromatographic determination of anions, cations and organic acids in biofuels
Quality and process control of biofuels require straightforward, fast and accurate analysis methods. Ion chromatography (IC) is at the leading edge of this effort. Traces of anions in a gasoline/ethanol blend can accurately be determined in the sub-ppb range after Metrohm Inline Matrix Elimination using anion chromatography with conductivity detection after sequential suppression. While the analyte anions are retained on the preconcentration column, the interfering organic gasoline/bioethanol matrix is washed away.Detrimental alkali metals and water-extractable alkaline earth metals in biodiesel are determined in the sub-ppm range using cation chromatography with direct conductivity detection applying automated extraction with nitric acid and subsequent Metrohm Inline Dialysis. Unlike high-molecular substances, ions in the high-ionic strength matrix diffuse through a membrane into the low-ionic water acceptor solution. In biogas reactor samples, low-molecular-weight organic acids stem from the biodegradation of organic matter. Their profile allows important conclusions concerning conversion in the anaerobic digestion reaction. Volatile fatty acids and lactate can be accurately determined by using ion-exclusion chromatography with suppressed conductivity detection after inline dialysis or filtration.
- 8.000.6012Automated logical dilution for ion chromatographic determinations
The combination of 850 Professional IC, 858 Professional Sample Processor, Dosino and MagIC NetTM software offers a variety of sophisticated ion chromatographic sample preparation techniques. One of these is the automated inline dilution of samples.After the first sample injection, MagIC NetTM verifies if the area of the sample peak lies within the calibration range. If the measured peak area is outside these limits, the software calculates the appropriate dilution factor, dilutes and automatically re-injects the sample. For all investigated ions (Li+, Na+, K+, Ca2+, Mg2+, F-, Cl- , NO2-, Br-, NO3-, SO42- ), automated logical dilution yielded coefficients of determination (R2) better than 0.9999. Direct-injection recoveries for cations and anions were within 98.6…99.5% and 93.4…100.4% respectively. In contrast, after logical dilution, recoveries for cations and anions were within 100.1…102.9% and 98.2…102.6% respectively. The relative standard deviations for all determinations involving diluted sample solutions were smaller than 0.91%.
- 8.000.6014Determination of anions and cations in aerosols by ion chromatography
The study of adverse effects of air pollution requires semi-continuous, rapid and accurate measurements of inorganic species in aerosols and their gas phase components in ambient air. The most promising instruments, often referred to as steam collecting devices, are the Particle-Into-Liquid-Sampler (PILS) coupled to wet-chemical analyzers such as a cation and/or anion chromatograph (IC) and the Monitoring instrument for AeRosols and GAses (MARGA) with two integrated ICs. Both instruments comprise gas denuders, a condensation particle growth sampler as well as pump and control devices. While PILS uses two consecutive fixed denuders and a downstream growth chamber, the MARGA system is composed of a Wet Rotating Denuder (WRD) and a Steam-Jet Aerosol Collector (SJAC). Although the aerosol samplers of PILS and MARGA use different assemblies, both apply the technique of growing aerosol particles into droplets in a supersaturated water vapor environment. Previously mixed with carrier water, the collected droplets are continuously fed into sample loops or preconcentration columns for on-line IC analysis. While PILS has been designed to sample aerosols only, MARGA additionally determines water-soluble gases. Compared to the classical denuders, which remove gases from the air sample upstream of the growth chamber, MARGA collects the gaseous species in a WRD for on-line analysis. In contrast to the gases, aerosols have low diffusion speeds and thus neither dissolve in the PILS denuders nor in the WRD. Proper selection of the ion chromatographic conditions of PILS-IC allows a precise determination, within 4 to 5 minutes, of seven major inorganic species (Na+, K+, Ca2+, Mg2+, Cl-, NO3- and SO4 2-) in fine aerosol particles. With longer analysis times (10-15 minutes) even airborne low-molecular-weight organic acids, such as acetate, formate and oxalate can be analyzed. MARGA additionally facilitates the simultaneous determination of HCl, HNO3, HNO2, SO2 and NH3.PILS and MARGA provide semi-continuous, long-term stand-alone measurements (1 week) and can measure particulate pollutants in the ng/m3 range.
- 8.000.6042Straightforward multipoint calibration using a single standard
The combination of 850 Professional IC, 858 Professional Sample Processor, Dosino and MagIC NetTM software offers a variety of automated ion chromatographic sample preparation and calibration techniques available as an anion, cation or dual channel system. Calibration is straightforward and requires only one multi-ion standard.Inline calibration allows the calibration of any standard concentration in the ppt range by using one single stable standard solution at the ppb level. By using a preconcentration column and switching the valves one, two or more times different calibration concentrations at the ultra-trace level can be created with unprecedented reproducibility. The inline preconcentration technique uses a pre-concentration column and is ideally suited for trace analysis in complex matrices, especially when combined with matrix elimination. Besides facilitating the preparation of g/L to ng/L calibration graphs Metrohm`s intelligent techniques are capable of logical decision making. While Metrohm`s intelligent Partial Loop technique (MiPT) allows samples with a wide concentration range to be injected without previous manual dilution, the intelligent inline dilution technique, after the first sample injection, compares peak areas, calculates, if necessary, the dilution factor, dilutes and automatically re-injects the sample. The presented inline techniques allow the rationalization of the time-consuming, error-prone and cost-intensive manual preparation of standard solutions. They guarantee that the determined sample concentrations always lie within the calibration range. Higher sample throughputs as well as lower analysis costs and improved data reliability are achieved.
- 8.000.6043Automated dialysis as a sample preparation tool in ion chromatography
The analytical challenge treated in the present work consists in the determination of chloride, phosphate and sulfate in the presence of difficult sample matrices that interact with the stationary column phase or even render it unusable. Metrohm`s patented stopped-flow dialysis coupled to the new 881 Compact IC pro ion chromatograph overcomes these drawbacks. Two standard solutions covering the concentration ranges 1.0…3.6 mg/L and 10…36 mg/L as well as two samples, an ultra-high temperature (UHT) processed milk and a baby milk powder, were characterized in terms of analyte concentration, relative standard deviation, calibration quality, carryover and recovery rates. While the five-point calibration curves yielded correlation coefficients (R) better than 0.9999, carryover (between two subsequent injections of a concentrated sample and a blank) was less than 0.49%. Recoveries for the low (10…36 mg/L) and high standard concentrations (1.0…3.6 mg/L) were within 91…99% and 94…100%, respectively. Automated compact stopped-flow dialysis is a leading-edge sample preparation technique that ensures optimum separation performance by effectively protecting the column from detrimental matrix compounds.
- 8.000.6044Fully automated sample preparation for liquid chromatographic content determinations
Inline coupling of the 815 Robotic Soliprep with an ion chromatograph (IC) allows the straightforward determination of anions and cations in tablets. After automatic solvent addition and subsequent comminution, the homogenized tablet samples (Singulair and Bezafibrat) are filtered and subsequently transferred to the injector. The completely automated sample preparation saves both time and money, guarantees traceability of each sample preparation step and yields correct and precise results. In the range of 0.2…50 mg/L, six-point calibration curves for anions and cations yield correlation coefficients better than 0.99990 and 0.99991, respectively. While relative standard deviations (RSDs) for sub-ppm levels of nitrate, sulfate, calcium and magnesium in Singulair and Bezafibrat are smaller than 3.64%, RSD of ppm levels of chloride is better than 0.83%. The application of further inline sample preparation steps such as pulverizing, extracting, filtering or diluting facilitates numerous custom-tailored setups for ion determinations in exacting matrices such as animal feed, sediments or food.
- 8.000.6058Analysis of airborne particulate matter by PILS-IC
This study compares air sampling data obtained by a filter-based method including off-line manual filter extraction followed by ion chromatographic analysis with those gained by an automated Particle-Into-Liquid-Sampler coupled to an ion chromatograph (PILS-IC).PILS-IC is a straightforward instrument for aerosol sampling that provides near real-time measurements for long-term unattended operation and is thus an indispensable tool to monitor rapid changes in aerosol particle ionic composition.
- 8.000.6064Microbore columns: a contribution to green chemistry
Available sample size, mass sensitivity, efficiency and the detector type are important criteria in the selection of separation column dimensions. Compared to conventional 4 mm i.d. columns, microbore columns excel, above all, by their low eluent consumption. Once an eluent is prepared, it can be used for a long time. Additionally, the lower flow rates of microbore columns facilitate the hyphenation to mass spectrometers due to the improved ionization efficiency in the ion source.With the same injected sample amount, a halved column diameter involves a lower eluent flow and results in an approximate four-fold sensitivity increase. In a converse conclusion, this means that with less sample amount, microbore columns achieve the same chromatographic sensitivity and resolution than normal bore columns. This makes them ideally suited for samples of limited availability.
- 8.000.6065Automated ion chromatographic determinations over six orders of magnitude
Metrohm`s intelligent Preconcentration Technique with Matrix Elimination (MiPCT-ME) excels in its capacity to perform automatic ion chromatographic determinations over 6 orders of magnitude. Crucial requirements for this are the system`s intelligence and the exact measurement of the sample volume. While the intelligence allows to compare results and take decisions, the dosing device takes over the high-precision liquid handling of even single-digit microliter volumes to the preconcentration column. By using only one analytical setup and without additional rinsing, samples containing both ultratraces and high concentrations can be analyzed.As the other Metrohm Inline Techniques, the MiPCT-ME technique presented reduces the workload, ensures complete traceability, is free of carryover effects and significantly improves accuracy and reproducibility of the results.
- 8.000.6071Trace-level determination of anions in the primary circuit of a PWR-type nuclear power plant using ion chromatography after inline sample preparation
The poster presents the ion chromatographic determination of organic degradation products such as glycolate, formate and acetate besides the standard anions fluoride, chloride, nitrate and sulfate.
- 8.000.6073Determination of anions in concentrated nitric acid by ion chromatography: the influence of temperature on column selectivity
Determination of chloride and sulfate in the presence of high nitrate concentrations. Optimization of the chromatographic separation by variation of the temperature and eluent composition.
- 8.000.6075Determination of pyrophosphate, trimetaphosphate, tripolyphosphate, and standard ions in detergents or fertilizers using IC with a high-capacity suppressor
Three different suppressor systems are compared in terms of sensitivity. Additionally, binary gradient elution was applied to analyze phosphates in the presence of mono- and divalent ions.
- 8.000.6076Sequential suppression for conductivity detection in ion chromatography
The poster describes how different suppressors (MSM and MCS) work and mentions possible applications.
- 8.000.6086Semi-continuous determination of anions, cations, and heavy metals in aerosols using PILS-IC-VA
This poster presents an approach that couples a Particle-Into-Liquid-Sampler (PILS) to a dual-channel ion chromatograph (IC) for measurement of aerosol anions and cations and a voltammetric measuring stand (VA) to determine the heavy metals. Feasibility of the PILS-IC-VA online system was demonstrated by collecting aerosol samples in Herisau Switzerland, at defined time intervals; air pollution events were simulated by burning lead- and cadmium-coated sparklers.
- AB-070Polarographic determination of nitrate in water samples, soil and plant extracts, vegetable juices, meat and sausages, fertilizers, liquid manure, etc.
The photometric determination of nitrate is limited by the fact that the respective methods (salicylic acid, brucine, 2,6-dimethyl phenol, Nesslers reagent after reduction of nitrate to ammonium) are subject to interferences. The direct potentiometric determination using an ion-selective nitrate electrode causes problems in the presence of fairly large amounts of chloride or organic compounds with carboxyl groups. The polarographic method, on the other hand, is not only more rapid, but also practically insensitive to chemical interference, thus ensuring more accurate results. The limit of quantification depends on the matrix of the sample and is approximately 1 mg/L.
- AB-121Determination of nitrate with the ion-selective electrode
It has been known for years that consuming too much nitrates from foodstuffs can result in cyanosis, particularly for small children and susceptible adults. According to the WHO standard, the hazard level lies at a mass concentration c(NO3-) ≥ 50 mg/L. However, more recent studies have shown that when nitrate concentrations in the human body are too high, they can (via nitrite) result in the formation of carcinogenic and even more hazardous nitrosamines.Known photometric methods for the determination of the nitrate anion are time-consuming and prone to a wide range of interferences. With nitrate analysis continually increasing in importance, the demand for a selective, rapid, and relatively accurate method has also increased. Such a method is described in this Application Bulletin. The Appendix contains a cselection of application examples where nitrate concentrations have been determined in water samples, soil extracts, fertilizers, vegetables, and beverages.
- AB-265Hamilton PRP-X100 IC anion column (6.1005.000)
This Bulletin describes the determination by ion chromatography of anions, particularly fluoride, chloride, nitrite, bromide, nitrate, and sulfate using the Hamilton PRPX100 IC anion column without chemical suppression.
- AN-D-001Metrohm IC Driver for OpenLab CDS
This application focuses on the simultaneous analysis of cations and suppressed anions with a dual channel Metrohm IC operated by OpenLab CDS.
- AN-D-002Anions and cations in beer
This Application Note presents ion chromatography as a precise method to analyze anions in beer as well as cations with non-suppressed conductivity. Automation with Inline Ultrafiltration is also discussed.
- AN-D-003Quality control of dialysis concentrates
Ion chromatography (IC) provides an automated, fast, and sensitive solution to accurately quantify cationic and anionic components including acetate simultaneously. This comprehensive approach makes IC an economic alternative to traditional techniques for the quality control of pharmaceutical solutions like haemodialysis concentrates. Ease-of use, accuracy, and the high-throughput of IC increase productivity and comply with the demands of modern routine and research labs.
- AN-EC-034Ion-selective electrodes based on screen-printed technology
Advances in polymeric membranes and screen-printed technologies have enabled miniaturized, portable potentiometric sensors ideal for point-of-care analysis.
- AN-I-004Nitrate content of a copper plating bath
Determination of nitrate in a copper plating bath after conversion of nitrate to ammonium. Direct potentiometric measurement using the NH3-ISE.
- AN-I-010Nitrate in carrot and beetroot juices – Fast and inexpensive analysis by standard addition
Nitrate is present in all common agricultural products and due to an extensive use of fertilizers, the nitrate content can be disconcertingly high in vegetables and their fabricated products, like juices. The nitrate content is regulated in many countries because it can form nitrosamines within the human body. Nitrosamines can potentially cause cancer and therefore, the World Health Organization (WHO) has defined an accepted daily intake (ADI) for nitrate of 3.7 mg/kg. To control the nitrate content e.g., in juices, a quick and inexpensive assessment of its concentration is performed via standard addition with a nitrate ion selective electrode . The method can be automated and is faster and less expensive compared to competing chromatographic or spectroscopic methods.
- AN-I-024Nitrate in surface water – Fast and inexpensive determination by direct measurement
Nitrate is naturally present in the environment. However, excessive concentrations of nitrate in surface and ground water are problematic as such concentrations have a negative effect on the water quality. Usually, excessive levels of nitrate area direct result of extensive usage of fertilizers in agriculture. Nitrate is easily washed from soils and can end up in surface or ground water. As the nitrate content is regulated in many countries, a quick and inexpensive assessment of its concentration is required to monitor the water quality.The nitrate concentration can easily be obtained by direct measurement using a nitrate ion selective electrode. First, a calibration is performed, afterwards, the samples are measured in less than a minute.This is a fast, inexpensive and reliable method to determine the nitrate content in various water samples.
- AN-I-025Purity of lucigenin by nitrate determination – Fast and inexpensive determination by standard addition
Lucigenin is one of the most often used chemiluminescent reagents and might be used for e.g., the indication of the presence of superoxide anion radicals.Lucigenin is rather expensive to buy, however, its synthesis only includes a two stage synthesis starting from acridanone. The first stage includes an Nmethylation, the second forms the lucigenin chloride, which is finally transformed into lucigenin nitrate. To check the purity of the synthesized lucigenin, ion measurement can be applied using a nitrate selective electrode. This is a fast and inexpensive method compared to competing methods such as ion chromatography.
- AN-N-001Nitrate and perchlorate in hydrochloric acid eluate
Determination of NO3- and ClO4- in the presence of a large excess of HCl using anion chromatography with direct conductivity detection (using time program for full scale change after 18 min).
- AN-N-003Five anions in solder paste
Determination of anions in solder paste after alcoholic extraction using anion chromatography with direct conductivity detection.
- AN-N-004Fluoride, chloride, bromide, nitrate, and sulfate in organic substances after Schoeniger combustion
Determination of anions in a Schoeniger absorption solution of a test mixture without decomposition of the H2O2 using anion chromatography with direct conductivity detection.
- AN-N-006Chloride, nitrate, phosphate, sulfate, and oxalate in dried potatoes
Determination of chloride, nitrate, phosphate, sulfate, and oxalate in dried potatoes using anion chromatography with direct conductometric detection.
- AN-N-010Chloride, nitrate, phosphate, and sulfate in plant leaf extracts
Determination of chloride, nitrate, phosphate and sulfate in plant leaf extracts using anion chromatography with direct conductometric detection.
- AN-N-013Chloride, nitrate, and sulfate in sugar-containing solutions
Determination of chloride, nitrate, and sulphate in sugar-containing solutions without matrix elimination using anion chromatography with direct conductometric detection.
- AN-N-014Five anions in effluent water
Determination of fluoride, chloride, nitrite, nitrate, and sulfate in an effluent sample using anion chromatography with direct conductometric detetction.
- AN-N-030Nitrate, sulfate, and thiocyanate in additives for building materials
Determination of nitrate, sulfate, and thiocyanate in additives for building materials using anion chromatography with direct conductometric detection.
- AN-N-063Nitrate in a nickel plating bath
Determination of nitrate in a nickel plating bath using anion chromatography with UV/VIS detection (205 nm).
- AN-O-038Separation of various sulfur/nitrogen compounds using ion-pair chromatography
Determination of sulfite, nitrite, nitrate, sulfate, imidodisulfonate, and peroxodisulfate using ion-pair chromatography with conductivity detection after suppression.
- AN-PAN-1009Online analysis of ammonia, nitrate, and nitrite in wastewater
This Process Application Note deals with online measurements of ammonia, nitrite, and nitrate in wastewater treatment plants. These nitrogen compounds are analyzed simultaneously using a drift-free colorimetric measurement in a multi-parameter process analyzer from Metrohm Process Analytics.
- AN-PAN-1042Online trace analysis of anions in the primary circuit of nuclear power plants
Measures to monitor or prevent corrosion are crucial in nuclear power plants, where significant risks to health and safety can occur if corrosion is left unchecked. Anions corrode metals under high temperature and pressure, therefore their concentrations must be monitored at all times. The analytical challenge in the primary circuit is detection of anions in the μg/L range alongside gram quantities of boric acid and lithium hydroxide. Precise, reliable trace analysis requires the method to be automated as much as possible. The 2060 IC Process Analyzer from Metrohm Process Analytics can measure several anions from a single injection, with combined Inline Preconcentration and Inline Matrix Elimination to measure low anion concentrations precisely and reliably time after time.
- AN-PAN-1046Online Determination of Anions in 50% NaOH and 50% KOH by IC (ASTM E1787-16)
The basic chemicals industry is responsible for producing thousands of raw materials at very large scales. The industries downstream rely upon a certain level of chemical purity to manufacture their own goods, as certain impurities can cause major issues in various processes. During the production of the basic chemicals NaOH and KOH, electrolysis of saturated brine solutions with membrane-cells yield the product which is further concentrated by evaporation. Impurities from the salts used in the brine will also be concentrated. Typically, this impurity analysis is performed offline with various hazardous chemicals with varying shelf-lives. The Process Ion Chromatograph is able to perform the measurement described in ASTM E1787-16 online, ensuring quality product without the need for time-consuming, hazardous laboratory experiments.
- AN-Q-003Online monitoring of trace levels of anions in boiler feed water
Determination of trace levels of chloride, nitrate, phosphate, and sulfate in boiler feed water using anion chromatography with conductivity detection after chemical suppression.
- AN-Q-006Online analysis of trace anions in borated water of a pressurized water reactor (PWR)
Water of the primary cycle of pressurized water reactors (PWR) contains boron for neutron absorption. The high borate content interferes with the direct analysis of trace anions. Inline Neutralization combined with variable preconcentration and Inline Matrix Elimination (MiPCT-ME) allows to remove boron as boric acid before injection.
- AN-Q-008Trace monitoring in distilled water using ion chromatography
The combination of 940 Professional IC Vario, 942 Extension Module Vario LQH and 941 Eluent Preparation Module enables process monitoring with the aid of ion chromatography. Assigned the designation ProfIC Vario 12 Anion, this combination is the anion variant of Metrohm Process IC. Intelligent preconcentration technology with matrix elimination is used for sample preparation. The use of an ELGA PURELAB® Flex 6 guarantees the supply of ultrapure water of the highest quality, particularly in cases of high numbers of samples.
- AN-S-003Fluoride, chloride, nitrate, and sulfate in drinking water
Determination of the anions in potable water using anion chromatography with conductivity detection after chemical suppression.
- AN-S-005Six anions in cooling water
Determination of fluoride, chloride, nitrite, nitrate, phosphate, and sulfate in cooling water using anion chromatography with conductivity detection after chemical suppression.
- AN-S-007Chloride, nitrate, phosphate, and sulfate in wastewater
Determination of chloride, nitrate, phosphate, and sulfate in wastewater using anion chromatography with conductivity detection after chemical suppression.
- AN-S-008Six standard anions in surface water
Determination of fluoride, chloride, nitrite, bromide, nitrate, and sulfate in surface water using anion chromatography with conductivity detection after chemical suppression.
- AN-S-009Six standard anions in soil eluate
Determination of fluoride, chloride, nitrite, nitrate, and sulfate in soil eluates using anion chromatography with conductivity detection after chemical suppression.
- AN-S-012Determination of lactate, chloride, nitrate, sulfite, and phosphate in wine
Determination of lactate, chloride, nitrate, sulfite, and phosphate in wine using anion chromatography and conductivity detection after chemical suppression.
- AN-S-018Fluoride, formate, chloride, nitrite, bromide, nitrate, phosphate, and sulfate in process water
Determination of fluoride, formate, chloride, nitrite, bromide, nitrate, phosphate, and sulfate in process water using anion chromatography with conductivity detection after chemical suppression.
- AN-S-020Nitrite and nitrate in wastewater
Determination of nitrite and nitrate in wastewater using anion chromatography with conductivity detection after chemical suppression.
- AN-S-024Fluoride, chloride, and nitrate in an acidic nickel/zinc bath
Determination of fluoride, chloride, and nitrate in a solution of NiSO4, ZnSO4 in sulfuric acid using anion chromatography with conductivity detection after chemical suppression.