IC – Frequently Asked Questions

Connections

  • FAQ
    I observe increased peak broadening although the column is new. What could be the cause?
    // Connections
  • Eluent and standards

  • FAQ
    The retention times change with each new eluent. What can I do?
    // Eluent and standards
  • FAQ
    What do I need in order to prepare eluents?
    // Eluent and standards
  • FAQ
    Which standard solutions can be used in ion chromatography?
    // Eluent and standards
  • FAQ
    The retention times change during the use of an eluent. Why?
    // Eluent and standards
  • Peristaltic pumps

  • FAQ
    Which precautions should I take when using peristaltic pumps?
    // Peristaltic pumps
  • Dosinos

  • FAQ
    How is the Dosino assigned to a particular function?
    // Dosinos
  • FAQ
    Is there a risk of carryover if I use the Dosino for sample input?
    // Dosinos
  • FAQ
    How are Dosinos used in ion chromatography?
    // Dosinos
  • FAQ
    Which dosing unit should I choose?
    // Dosinos
  • FAQ
    How can I clean a blocked dosing unit?
    // Dosinos
  • FAQ
    Can I use a Dosino for eluent preparation (Eluent Dosino), for Liquid Handling, and for Suppressor Regeneration?
    // Dosinos
  • Columns

  • FAQ
    Is it possible to regenerate IC separation columns?
    // Columns
  • FAQ
    To what must I pay particular attention when using IC columns?
    // Columns
  • FAQ
    How do I store the IC column when it is not in use?
    // Columns
  • FAQ
    How do I find out whether a particular separation column is suitable for my tasks?
    // Columns
  • FAQ
    How do I protect the column against particles and unwanted components?
    // Columns
  • FAQ
    What is an iColumn?
    // Columns
  • Suppression

  • FAQ
    Is the color indicator of the adsorption material harmful?
    // Suppression
  • FAQ
    What is "Dosino Regeneration"?
    // Suppression
  • FAQ
    How is the MSM operated?
    // Suppression
  • FAQ
    To what must I pay particular attention for the MSM?
    // Suppression
  • FAQ
    How do I protect the suppressor?
    // Suppression
  • FAQ
    How do I use the MCS?
    // Suppression
  • Maintenance / Troubleshooting

  • FAQ
    The background conductivity is too high.
    // Maintenance Troubleshooting
  • FAQ
    Does a Metrohm IC system have a maintenance manual?
    // Maintenance Troubleshooting
  • FAQ
    The peak areas are smaller than expected.
    // Maintenance Troubleshooting
  • FAQ
    The measured values exhibit excessive scattering.
    // Maintenance Troubleshooting
  • FAQ
    The baseline is drifting excessively.
    // Maintenance Troubleshooting
  • FAQ
    The pressure in the system has noticeably decreased.
    // Maintenance Troubleshooting
  • FAQ
    Does Metrohm offer service agreements?
    // Maintenance Troubleshooting
  • FAQ
    How are the Metrohm Service technicians qualified?
    // Maintenance Troubleshooting
  • FAQ
    The retention times are not reproducible.
    // Maintenance Troubleshooting
  • FAQ
    Which maintenance work can I carry out myself?
    // Maintenance Troubleshooting
  • FAQ
    The baseline is noisy.
    // Maintenance Troubleshooting
  • FAQ
    The peaks exhibit extreme broadening.
    // Maintenance Troubleshooting
  • FAQ
    Individual peaks are too large.
    // Maintenance Troubleshooting
  • FAQ
    The pressure in the system has noticeably increased.
    // Maintenance Troubleshooting