- WP-067Quality control of semiconductor acid baths as per ASTM E1655 – Time- and cost-efficient with NIRS
The demand for microelectronics and printed circuit boards (PCBs) has steadily increased as more flat panel displays, LEDs, photovoltaics, and other essential intermediates are required to create modern consumer devices. This is favorable for the semiconductor industry, though challenges may arise to deliver on time while upholding high quality standards. To be successful, several processes must be optimized in order to increase production efficiency. This White Paper describes the capabilities of the modern analytical method near-infrared (NIR) spectroscopy for assessing the quality of acid baths for etching of microelectronics and printed electronics. Not only are analysis times sharply reduced to less than a minute, the related running costs are also significantly lower – certainly a boost in efficiency that should not be overlooked!
- WP-068Recommendations for titration methods validation
The objective of validation of an analytical procedure is to demonstrate that it is suitable for its intended purpose. Recommendations for the validation of analytical methods can be found in ICH Guidance Q2(R1) Validation of Analytical Procedures: Text and Methodology and in USP General Chapter <1225> Validation of Compendial Procedures. The goal of this white paper is to provide some recommendations for the validation of titration methods.
- WP-069(Un)Grounded: Grounded and floating measurements and their application in electrochemical research
In this White Paper, details of the electronic (PGSTAT) and electrochemical cell grounding are presented together with the necessity of using a floating PGSTAT for different application and experimental examples. Due to the wide variation of experimental requirements and kinds of electrochemical cells, the use of an electrochemical instrument with a selectable floating feature (such as VIONIC) which brings additional versatility to the user is recommended.
- WP-070On-site Identification of Improvised Incendiary Devices: Integrated Chemical ID and Decision Guidance with MIRA DS and HazMasterG3®
Handheld Raman is ever evolving. The combination of large libraries, a compact and easy-to-use system, and predictive Hazmat software make MIRA DS a powerful tool for defense and security professionals. Identify on-site materials, get hazard information, and make quick decisions about response to dangerous situations.
- WP-071Improving the corn to ethanol fermentation process with near-infrared spectroscopy (NIRS)
The fermentation of corn starch to produce ethanol is a complex biochemical process that requires monitoring of many different parameters (e.g., solids, pH, sugar profile, glycerol, lactic and acetic acid, and water and ethanol content). Traditional laboratory analysis using primary methods (e.g. Karl Fischer titration) takes about an hour to complete and is a limiting step for increasing plant capacity and efficiency. As a fast and non-destructive analytical technique, near-infrared spectroscopy (NIRS) can replace routine laboratory analysis, decreasing operating costs and increasing plant efficiency and capacity. This White Paper describes the capabilities of the modern analytical method near-infrared (NIR) spectroscopy for monitoring and improving the fermentation process of corn to ethanol.
- WP-072Fluorescence-free 785 nm material ID with MIRA XTR DS
In this White Paper, you will learn about MIRA XTR DS – the smallest, smartest, most flexible handheld Raman system with the largest libraries available on the market! MIRA XTR DS has all the benefits of 785 nm Raman interrogation: compact size, low laser power, sample preservation, long battery lifetimes... now with fluorescence rejection. Additionally, there is improved sensitivity and resolution over 1064 nm systems. This opens up new possibilities for 785 nm Raman, including strongly colored materials, common excipients, illicit materials, and more.
- WP-073On-site detection of hexavalent chromium in protective paint primers
It is widely accepted that prolonged exposure to hexavalent chromium compounds can have dire health effects. This has led to increased regulation of chromium-containing products and greater demand for technologies that can positively identify hexavalent chromium in potential matrices. These include paints, dyes, and primers, which can pose a problem for interrogation with Raman, as strongly colored materials often exhibit fluorescence when stimulated at 785 nm. Fluorescence can obscure the Raman signal and prevent positive identification. MIRA XTR DS provides all the functionality of handheld material ID with a new capability that selectively eXTRacts the Raman signal from fluorescent materials. Fluorescence rejection at 785 nm provides higher sensitivity and resolution than 1064 nm systems, as well as a much wider scope of applications amenable to Raman spectroscopy. MIRA XTR DS offers a comprehensive and versatile material ID test solution for field operations.
- WP-074Determination of polyribosylribitol phosphate (PRP) in Haemophilus influenzae vaccine using ion chromatography with pulsed amperometric detection
Haemophilus influenzae type B (Hib) is a major cause of bacterial meningitis in children in many countries. The capsular polysaccharide (PS) of Hib plays an important role in the virulence of the organism. The polysaccharide capsule hides cell surface components from elements of the mammalian immune system, such as antibodies and complement proteins that otherwise would activate mechanisms to kill the pathogen. Vaccines require rigorous characterization and assays to ensure final product quality and consistency. For glycoconjugate vaccines, it is important to measure both free and total PS to ensure the quality. A large amount of unconjugated PS may suppress immunity to the antigen. Additionally, the presence of free PS is a key indicator of process consistency. Current methods to determine PS content in vaccines such as Hib are imprecise and unreliable, especially if the vaccine contains a sugar stabilizer (e.g. lactose). Ion chromatography with pulsed amperometric detection (IC-PAD, or HPAEC-PAD) offers a simpler procedure and better sensitivity than other assays to quantify PS (here, polyribosylribitol phosphate [PRP]) in Hib vaccine.
- WP-075Simple determination of haloacetic acids (HAAs) in potable water with ion chromatography hyphenated to mass spectrometry
Haloacetic acids (HAAs) are commonly produced as disinfection byproducts (DBPs) from water treatment processes. Some HAAs are regulated by the authorities and have been classified as potentially carcinogenic. They have traditionally been analyzed by gas chromatography (GC), a technique that requires time-consuming sample extraction and derivatization, leading to higher costs per analysis. Ion chromatography hyphenated to mass spectrometry (e.g., single or triple quadrupole MS systems) is a powerful tool that can handle many challenging analytical tasks such as measuring μg/L levels of HAAs in potable water samples. This White Paper explains the benefits of using this hyphenated technique for the accurate measurement of HAAs in potable water.
- WP-076Process analyzers as proactive solutions for online corrosion monitoring
White paper on monitoring corrosion and the benefits of online or inline chemical analysis over manual sampling and offline laboratory methods for corrosion monitoring. Online and inline process application solutions for corrosion prevention with related application notes for further information are presented.
- WP-077Robust multiparameter analysis of infant and follow-on formulas with ion chromatography (IC)
Free white paper gives comprehensive overview of how to reliably assess the quality of infant formula with ion chromatography.
- WP-078Adsorbable organic fluorine (AOF) for screening of PFAS in waters
Learn about PFAS, their impact on water quality, EU Directive 2020/2184, and the benefits of AOF measurement using combustion ion chromatography (CIC).
- WP-079How to characterize a catalyst? Cyclic voltammetry in action
This White Paper introduces the principles of cyclic voltammetry (CV) and the various ways it can be used for catalyst investigation. A case study and helpful glossary are provided to support your understanding.
- WP-080Seamless electrochemical measurements with VIONIC powered by INTELLO
This White Paper introduces seamless measurements that are possible with VIONIC powered by INTELLO and applications that can benefit from this unique feature. The combination of software and new generation electronics provides data in real-time with no gaps or missed reactions.
- WP-081Fast determination of AOX in waters according to DIN 38409-59
Monitor adsorbable organic halogens (AOX) in water using combustion ion chromatography (CIC) for precise analysis of AOCl, AOBr, AOI, and total AOX.
- WP-082Measuring inorganic cations and amines with ion chromatography mass spectrometry (IC-MS)
This white paper presents IC-MS as powerful analysis technique. This multiparameter method determines various analytes such as inorganic cations and amines in one run.
- WP-083Hyphenated electrochemical-Raman spectroscopy: Another dimension for your research
White paper about Raman spectroscopy and electrochemistry and their combination (electrochemical Raman).
- WP-084Quality control of analytical parameters in battery production
Lithium-ion batteries (LIBs) are the most common rechargeable options available today. Production of LIBs needs to follow stringent quality standards.
- WP-085Improved antioxidant monitoring of in-service industrial lubricants
Voltammetry (VA) is a fast and established method for testing the remaining antioxidant content in industrial lubricants. The flexible and modular Metrohm VA system setup discussed in this White Paper delivers more repeatable and more reproducible results which fulfill all ASTM requirements. Additionally, users can automate the complete analysis process which makes it possible to run series of samples completely unattended.
- WP-086Measuring organic acids and inorganic anions with ion chromatography mass spectrometry
This White Paper focuses on selected IC-MS applications for the straightforward identification and quantification of organic acids and inorganic anions in different matrices.
- WP-087Green alternative methods for voltammetric analysis in different water matrices
This White Paper presents four different «green» sensors: the scTRACE Gold, screen-printed electrodes, the glassy carbon electrode, and the Bi drop electrode from Metrohm that can be used to determine low concentrations of heavy metals in different sample matrices, such as boiler feed water, drinking water, and sea water.
- WP-088Simplified analysis of dairy products with Metrohm Inline Dialysis
This White Paper compares automated Inline Ultrafiltration and Inline Dialysis to the traditional Carrez clarification procedure for the analysis of milk samples by ion chromatography (IC). A continuous test series over approximately six months proved Inline Dialysis to be a reliable and valuable alternative to treat dairy products prior to IC analysis.
- WP-089Water content determination in ketones using Hydranal™ NEXTGEN FA reagents
With Hydranal™ NEXTGEN FA reagents, the water content in ketones can be determined quickly and reliably. Compared to other existing KF reagents for ketones on the market, the side reactions are measurably better suppressed.
- WP-090Automated water hardness determination according to ASTM D8192
The ASTM D8192 standard allows analysts to determine water hardness in different water matrices by complexometry with automated photometric endpoint recognition, increasing the reproducibility and the precision of the results.
- WP-091Case study: Ion chromatography in pharmaceutical research and development
This White Paper will walk you through the selection process of ion chromatography as the best analytical tool in the product development of a cell-based gene therapy.
- WP-092USP monograph modernization initiative leading to modern ion chromatography-based methods
The USP and FDA started to modernize several monographs and General Chapters. In many cases, IC-focused methods have replaced older, wet chemistry procedures. Learn more about the USP modernization initiative and the advantages of ion chromatography in this white paper.
- WP-093Significant cost savings through dynamic ventilation during nitrification in wastewater treatment
This White Paper gives an overview of the energy-intensive nitrification process that converts ammonia into less harmful nitrogen compounds at wastewater treatment plants (WWTPs). It displays the results from a field test at a WWTP, showcasing the positive influence of single-method process analyzers on the efficiency of the nitrification process.
- WP-094OMNIS NIRS: An efficiency boost for your laboratory
This White Paper discusses the concept and benefits of NIR spectroscopy and outlines several real-life laboratory application examples with the use of OMNIS NIRS, the cutting-edge NIR spectrometer from Metrohm.
- WP-095The future of manufacturing and commercializing green ammonia with electrochemistry
Free White Paper outlines the fundamental principles of the nitrogen reduction reaction. It then delves into the technical barriers hindering the industrialization of green ammonia production, their impact on final yield and selectivity, and potential strategies or research gaps to overcome these issues.
Did you know?
The OMNIS Model Developer creates prediction models from your data set with a single click.
Show another