Applikationer
- 410000016-AQuantification of Urea in Ethanol by Raman Spectroscopy
Urea in widely employed as a nitrogen-release fertilizer with more than 90 % of urea production destined for agricultural applications. Urea is also known to form complexes with fatty acids, which have been employed for separation of complex mixtures and purification processes. In this application note, we present the quantification of the concentration of urea in ethanol by Raman Spectroscopy and show how this method can be employed for determining the percentage of urea in a solid inclusion compound with stearic acid.
- 8.000.6011Ion chromatographic determination of anions, cations and organic acids in biofuels
Quality and process control of biofuels require straightforward, fast and accurate analysis methods. Ion chromatography (IC) is at the leading edge of this effort. Traces of anions in a gasoline/ethanol blend can accurately be determined in the sub-ppb range after Metrohm Inline Matrix Elimination using anion chromatography with conductivity detection after sequential suppression. While the analyte anions are retained on the preconcentration column, the interfering organic gasoline/bioethanol matrix is washed away.Detrimental alkali metals and water-extractable alkaline earth metals in biodiesel are determined in the sub-ppm range using cation chromatography with direct conductivity detection applying automated extraction with nitric acid and subsequent Metrohm Inline Dialysis. Unlike high-molecular substances, ions in the high-ionic strength matrix diffuse through a membrane into the low-ionic water acceptor solution. In biogas reactor samples, low-molecular-weight organic acids stem from the biodegradation of organic matter. Their profile allows important conclusions concerning conversion in the anaerobic digestion reaction. Volatile fatty acids and lactate can be accurately determined by using ion-exclusion chromatography with suppressed conductivity detection after inline dialysis or filtration.
- 8.000.6020Titrimetric analyses of biofuels
Several testing methods such as the determination of the acid and the iodine numbers in biodiesel as well as the quantification of sulfate and chloride in bioethanol are described.
- AB-177Automatic determination of the bromine number and the bromine index in petroleum products
The bromine number and bromine index are important quality control parameters for the determination of aliphatic C=Cdouble bonds in petroleum products. Both indices provide information on the content of substances that react withbromine. The difference between the two indices is that the bromine number indicates the consumption of bromine in gfor 100 g sample and the bromine index in mg for 100 g sample.This Application Bulletin describes the determination of the bromine number according to ASTM D1159, ISO 3839, BS2000-130, IP 130, GB/T 11135 and DIN-51774-1. The bromine index determination for aliphatic hydrocarbons is described according to ASTM D2710, IP 299, GB/T 11136 and DIN 51774-2. For aromatic hydrocarbons the determination of the bromine index is described according to ASTM D5776 and SH/T 1767. UOP 304 is not recommended for the determination of the bromine number or bromine index because its titration solvent contains mercuric chloride.
- AB-280Automatic Karl Fischer water content determination with the 874 Oven Sample Processor
Generally speaking, the gas extraction or oven method can be used for all samples which release their water when they are heated up. The oven method is indispensable in cases in which the direct volumetric or coulometric Karl Fischer titration is not possible, either because the sample contains disruptive components or because the consistency of the sample makes it very difficult or even impossible to transfer it into the titration vessel.The present Application Bulletin describes automatic water content determination with the aid of the oven technique and coulometric KF titration, using samples from the food, plastic, pharmaceutical and petrochemical industry.
- AB-404Total acid number titration of petroleum products
The determination of the acid number plays a significant role in the analysis of petroleum products. This is manifested in the numerous standard procedures in use over the world (internal specifications of multinational companies, national and international specifications of ASTM, DIN, IP, ISO, etc.). These procedures differ mainly in the composition of the used solvents and titrants.This bulletin describes the determination of the acid number in petroleum products by applying different types of titration.The potentiometric determination is described according to ASTM D664, the photometric according to ASTM D974 and the thermometric titration according to ASTM D8045.
- AB-427Acid number in petroleum products with thermometric titration
This Application Bulletin describes the determination of the total acid number in various oil samples by catalytic thermometric titration as per ASTM D8045.
- AB-435Connection of the Eco Titrator to the PC
Eco Titrators provide the capability to send PC/LIMS reports directly to a PC. This feature is mainly used to transfer data to an external LIMS system or to simply store the data in a digitally on the PC. Additionally, it is possible to control the Eco Titrator by RS232 commands if the connection is set up according to the procedure described below.The data transfer from the Eco Titrator to a PC can be done by a software- or a hardware-based option. Additional accessories are needed for the hardware-based option whereas for the software-based option two additional softwares must be installed. Both solutions are described in this document.
- AB-445Installation instruction: MVA-25 – 884 Professional VA fully automated for the determination of antioxidants with automatic sample preparation
This Application Bulletin contains installation instructions for the MVA-25 (with automatic sample preparation) used to measure antioxidants in lubricants.
- AN-C-097Cations in ethanol used as biofuel
Determination of traces of lithium, sodium, ammonium, potassium, calcium, and magnesium in ethanol using cation chromatography with direct conductivity detection after Metrohm Inline Matrix Elimination.
- AN-C-101Cations in biodiesel with fully automated aqueous extraction and subsequent dialysis
Determination of potassium, magnesium, and calcium in biodiesel using cation chromatography with direct conductivity detection applying automated extraction and subsequent Metrohm Inline Dialysis.
- AN-C-177Dicyclohexylamine (DCHA) and methyldicyclohexylamine (MDCHA) in cooling lubricant applying Inline Dialysis
Abrasive machining of e.g., metal parts requires a cooling lubricant. Their purpose besides cooling and lubrication is to inhibit corrosion. Amines are added to the emulsion to keep the pH high. In the actual application, DCHA and MDCHA have to be analyzed besides other amine components and inorganic cations. To avoid oil contamination on the IC system, Inline Dialysis is applied. The detection is performed by direct conductivity detection.
- AN-C-193Alkyl amines in scrubber solutions
Harmful industrial flue gases like H2S and CO2 cause corrosion of pipes and damage the environment. Adding the correct amount of amines in scrubber solutions, e.g. ethanolamines and methylamines, will neutralize these gases («gas sweetening»). Non-suppressed cation analysis with direct conductivity detection is a straightforward and robust technique for the quantification of monoethanolamine (MEA), diethanolamine (DEA), triethanolamine (TEA), monomethylamine (MMA), dimethylamine (DMA), and trimethylamine (TMA) via ion chromatography. Thanks to the high capacity of the Metrosep C 6 column, large volumes can be injected without compromising the peak shapes. The analytical technique can be used at laboratory scale but also for process analysis.
- AN-CIC-029Organic halides in crude oil
Crude oil typically contains no organic halides. These are introduced at production sites, in pipelines, or in storage tanks. These components produce HF, HCl, and other acids in reforming and hydro-treating processes, leading to corrosion and catalyst poisoning. Speciation of the halides is an important parameter to measure in order to trace the contamination source. The current specifications expect to find less than 2 mg/kg organic chlorine in crude oil. Sulfur in crude oil could be quantified on the fly. Due to the specific request in this application, only the halogens are determined.
- AN-COR-004Corrosion part 4 – equivalent circuit models
Electrochemical impedance spectroscopy or EIS has been used effectively to measure the polarization resistance for corrosion systems and for the determination of corrosion mechanisms.
- AN-COR-008Stepwise dissolution measurement
In this Application Note, stepwise dissolution measurement (SDM) is applied to aluminum samples coated with different materials, in order to gain insights in corrosion protection. The combination of the Autolab PGSTAT204 with the 1 L Autolab corrosion cell and the NOVA software provides the suitable setup to perform SDM and other corrosion experiments.
- AN-COR-014Corrosion Inhibitor Efficiency Measurement in Turbulent Flow Conditions with the Autolab Rotating Cylinder Electrode (RCE), According to ASTM G185
The rotating cylinder electrode (RCE) is a technique used in corrosion research to simulate in a laboratory environment the turbulent flow which usually occurs when liquids are transported through pipelines. The RCE is used to generate a turbulent flow at the surface of a sample, simulating the pipe flow conditions. Experiments that involve an RCE are regulated by the ASTM G185 standard. In this application note, The RCE with a 1018 carbon steel cylinder sample was used with the linear polarization (LP) measurement technique.
- AN-CS-016Metrosep C Supp 2 - 150/4.0: Amines applying suppressed cation chromatography
The Metrosep C Supp 2 column family is polystyrene/divinylbenzene based and therefore sequential cation suppression may be applied. This AN shows the separation and detection of different amines on the 150 mm version of the column with subsequent conductivity detection after sequential cation suppression.
- AN-EC-002Reference electrodes and their usage
A reference electrode has a stable and well-defined electrochemical potential (at constant temperature), against which the applied or measured potentials in an electrochemical cell are referred. A good reference electrode is therefore stable and non-polarizable. In other words, the potential of such an electrode will remain stable in the used environment and also upon the passage of a small current. This application note lists the most used reference electrodes, together with their range of use.
- AN-EC-015Metrohm 663 VA stand for Heavy Metal Ions detection in Water Sample
The determination of heavy metal ions in a solution is one of the most successful application of electrochemistry. In this application note, anodic stripping voltammetry is used to measure the presence of two analytes, in a sample of tap water.
- AN-EIS-005Electrochemical Impedance Spectroscopy (EIS) Part 5 – Parameter Estimation
In the application note AN-EIS-004 on equivalent circuit models, an overview of the different circuit elements that are used to build an equivalent circuit model was given. After identifying a suitable model for the system under investigation, the next step in the data analysis is estimation of the model parameters. This is done by the non-linear regression of the model to the data. Most impedance systems come with a data-fitting program. In this application note, the way NOVA is uses to fit the data is shown.
- AN-EIS-006Electrochemical Impedance Spectroscopy (EIS) Part 6 – Measuring raw signals in EIS
In this application note, the advantage of recording the raw time domain data for each individual frequency during an electrochemical impedance measurement is described.
- AN-EIS-007EIS Data fitting – How to obtain good starting values of equivalent circuit elements
Electrochemical impedance spectroscopy (EIS) is a powerful technique which provides information about the processes occurring at the electrode-electrolyte interface. The data collected with EIS are modeled with a suitable electrical equivalent circuit. The fitting procedure will change the values of the parameters until the mathematical function matches the experimental data within a certain margin of error. In this Application Note, some suggestions are given in order to get acceptable initial parameters and to perform an accurate fitting.
- AN-H-010Determination of calcium in drilling fluids
Thermometric titration quickly and accurately assesses the total solids content of fluids employed in drilling oil and gas wells within minutes.
- AN-H-018Determination of chloride in drilling fluids
Determination of chloride in oil well drilling fluids.
- AN-K-012Water in turbine oil
The water content of turbine oil is determined according to Karl Fischer. Because of the low water content of the sample, coulometric titration is used.
- AN-K-070Water in petroleum products
Moisture in petroleum products causes several issues: corrosion and wear in pipelines and storage tanks, an increase in debris load resulting in diminished lubrication, blocked filters, or even harmful bacterial growth. As a result, increased water content can lead to infrastructure damage, higher maintenance costs, or even unwanted downtimes.Coulometric Karl Fischer titration is the method of choice for low water content in petroleum products. Using a Karl Fischer oven to vaporize the water present in the sample prior to titration not only greatly reduces matrix interferences, it can also be fully automated. This allows a reliable and cost-efficient analysis of the water content according to ASTM D6304 (Procedure B) in products such as diesel, hydraulic oil, lubricant, additive, turbine oil, and base oil.
- AN-K-07234433 HYDRANAL™ NEXTGEN Coulomat AG-FI
Karl Fischer reagents contain buffer substances (usually imidazole) since the reaction constant is dependent on the pH value. A constant pH therefore ensures the most repeatable results. In 2015, imidazole was classified by European Union the as a CMR (carcinogenic, mutagenic or toxic) substance and the statement H360D was added, stating possible harm to fertility or a fetus. Meanwhile, other reagents free of imidazole are available for purchase. This Application Note summarizes test measurements with 34433 HYDRANAL™ NEXTGEN Coulomat AG-FI.
- AN-K-074Water content in crude oil determined with Karl Fischer titration
To determine water in crude oil, ASTM D4928 recommends coulometric Karl Fischer titration with the oven method, allowing full automation for high reproducibility.
- AN-NIR-022Quality Control of Gasoline
In recent years, there has been a significant push to reduce the environmental impacts of fuels through improvements to fuel quality. The determination of key quality parameters of gasoline, namely research octane number (RON, ASTM D2699-19), motor octane number (MON, ASTM D2700-19), anti knock index (AKI), aromatic content (ASTM D5769-15), and density, conventionally requires several different analytical methods, which are laborious and need trained personnel. This application note demonstrates that the XDS RapidLiquid Analyzer, operating in the visible and near-infrared spectral region (Vis-NIR), provides a cost-efficient and fast solution for the multiparameter analysis of gasoline.
- AN-NIR-024Quality control of pyrolysis gasoline
Pyrolysis gasoline (Pygas) is a by-product of ethylene production, which contains unwanted conjugated diolefins making it unsuitable as a motor fuel. To overcome this limitation, the olefin content needs to be reduced below 2 mg/g pygas in a selective hydrogenation unit (SHU). The diene value, or maleic anhydride value (MAV), is usually determined by the lengthy Diels-Alder wet chemical method (UOP326-17), requiring highly trained analysts. In contrast to the primary method, near-infrared spectroscopy (NIRS) is a cost-efficient and fast analytic solution for the determination of diene value in pyrolysis gasoline.
- AN-NIR-041Multiparameter Quality Control of Lubricants with NIRS
For lubricant analysis, determination of the Acid Number (ASTM D664), viscosity (ASTM D445), moisture content (ASTM D6304), and color number (ASTM D1500) require the use of multiple analytical technologies and, in part, large volumes of chemicals. This application note demonstrates that the XDS RapidLiquid Analyzer operating in the visible and near-infrared spectral region (Vis-NIR) provides a fast and cost-efficient alternative for the determination of the AN, viscosity, moisture content, and color number of lubricants. With no sample preparation or chemicals needed, Vis-NIR spectroscopy allows for multi parameter analysis of lubricants in less than one minute.
- AN-NIR-071Automated acid number determination in lubricants with near-infrared spectroscopy
Acid Number (AN) analysis of lubricants (ASTM D664) can be a lengthy and costly process due to usage of large amounts of chemicals and required cleaning steps of the analytical equipment between each measurement. This application note demonstrates that the XDS RapidLiquid Analyzer operating in the visible and near-infrared spectral region (Vis-NIR) provides a cost-efficient, fast alternative for the determination of the acid number of lubricants. With no sample preparation or chemicals needed, Vis-NIR spectroscopy allows for the analysis of AN in less than a minute.
- AN-NIR-080Quality Control of Diesel
The cetane index (ASTM D613), flash point (ASTM D56), cold filter plug point (CFPP) (ASTM D6371), D95 (ISO 3405), and viscosity at 40°C (ISO 3104) are key parameters to determine for diesel quality. The primary test methods are labor intensive and challenging due to the need to use different analytical methods. This application note demonstrates that the NIRS XDS RapidLiquid Analyzer provides a cost-efficient and fast solution (under 1 minute) for the simultaneous determination of these key parameters in diesel.
- AN-NIR-086Quality Control of Diesel Exhaust Fluid
The quality control of diesel exhaust fluids (DEF) is key to ensure the optimal catalytic performance and prevent damage to the exhaust system in diesel vehicles. The standard method to determine urea content is measuring the refractive index (ISO 22241-2:2019). The issue is that although this method is fast, it is not as accurate as other methods (e.g., HPLC). This application note demonstrates that the DS2500 Liquid Analyzer provides a fast solution with high accuracy for the determination of urea in DEF. With no sample preparation or chemicals needed, visible near infrared (Vis-NIR) spectroscopy allows for the analysis of diesel exhaust fluids in less than a minute.
- AN-NIR-093Quality Control of fermentation processes
The production of biofuels from renewable feedstock has grown immensely in the past several years. Bioethanol is one of the most interesting alternatives for fossil fuels, since it can be produced from raw materials rich in sugars and starch. Ethanol fermentation is one of the oldest and most important fermentation processes used in the biotechnology industry. Although the process is well-known, there is a great potential for its improvement and a proportional reduction in production costs. Due to the seasonal variation of feedstock quality, ethanol producers to need to monitor the fermentation process to ensure the same quality product is achieved. Near-infrared spectroscopy (NIRS) offers rapid and reliable prediction of ethanol content, sugars, Brix, lactic acid, pH, and total solids at any stage of the fermentation process.
- AN-NIR-094Bromine number in pyrolysis gasoline
This application note presents near-infrared spectroscopy (NIRS) as an alternative for bromine number determination in pyrolysis gasoline.
- AN-NIR-096Water in diesel with NIRS
This Application Note highlights near-infrared spectroscopy as a faster, cost-effective alternative to KF titration for predicting water content in diesel fuel.
- AN-NIR-097Total base number in lubricants with near-infrared spectroscopy
Alkaline additives in engine lubricants are used to prevent the build-up of acids and as a result, they inhibit corrosion. The total base number (TBN) indicates the amount of basic additives present in samples and thus can be used as a measure for the degradation of the lubricant. The standard test method for TBN in lubricants is potentiometric titration according to ASTM D2896. This method requires the use of toxic reagents involves a labor-intensive cleaning procedure. In contrast to the primary method, near-infrared spectroscopy (NIRS) is a fast analytical technique which does not produce any chemical waste and completes the TBN analysis in less than one minute.
- AN-NIR-113Research octane number (RON) determination in isomerate
The standard method to determine RON in isomerate is with expensive and maintenance-intensive engines. In contrast to this, the research octane number can also be analyzed by near-infrared spectroscopy (NIRS). NIRS provides accurate results within one minute without the need for any sample preparation or chemicals.
- AN-NIR-114Determination of RON, aromatics, benzene, olefins, and density in reformate by NIRS
The determination of key quality parameters of reformate—namely research octane number (RON, ASTM D2699-19), aromatic content (ASTM D5769-15), benzene content, olefin content, and density—requires time-consuming and laborious conventional methods. In contrast, the Metrohm DS2500 Liquid Analyzer can measure all of these parameters, providing results within one minute without any sample preparation.
- AN-O-017Glycolic acid, formic acid, acetic acid and carbonic acid in a scrubber solution
Determination of glycolic acid, formic acid, acetic acid and carbonic acid in a scrubber solution using ion-exclusion chromatography with conductivity detection after chemical suppression.
- AN-PAN-1052Online process monitoring of octane number during catalytic reforming
In refineries, high octane products are desired since they are used to produce premium gasoline. Catalytic reforming converts heavy naphtha into a high octane liquid product called reformate (a mixture of aromatics and iso-paraffins C7 to C10). The reformate must be constantly monitored to ensure high throughput along the refining process. Traditionally, the octane numbers can be measured by two different methodologies: Inferred Octane Models (IOM) and laboratory octane engine analysis. However, these do not provide «real-time» results and require constant maintenance and human intervention to adapt to current operation conditions. «Real-time» analysis of the octane number in fuels can be performed online via near-infrared spectroscopy (NIRS) technology, which fits well within the international standards (ASTM). Utilization of a Metrohm Process Analytics NIRS XDS Process Analyzer (ATEX version) in conjunction with a sample preconditioning system makes analysis of the octane number simple, fast, and reliable, allowing quick adjustments to the process for a better quality product and higher profitability.
- AN-PAN-1057Inline monitoring of fermentation processes
Many fermentation quality parameters can be monitored simultaneously directly in the tank with inline near-infrared spectroscopy, such as the 2060 The NIR Analyzer.
- AN-R-034Oxidation stability of diesel, biodiesel, and blends
Sustainable biodiesel can be blended with petroleum diesel. The 893 Professional Biodiesel Rancimat measures the oxidation stability of biodiesel and its blends.
- AN-S-041Sulfate in diesel engine coolant using dialysis for sample preparation
Determination of sulfate in diesel engine coolant using anion chromatography with conductivity detection after chemical suppression and dialysis for sample preparation.
- AN-S-109Six anions in Schoeniger absorption solution using the column Metrosep A Supp 5 - 150/4.0
Determination of chloride, nitrite, bromide, nitrate, phosphate, and sulfate in Schoeniger absorption solution using anion chromatography with conductivity detection after chemical suppression.
- AN-S-191Chloride, nitrite, and sulfate in a used zinc bath containing cooling lubricants
Determination of chloride, nitrite, and sulfate in a used zinc bath using anion chromatography with conductivity detection after chemical suppression.
- AN-T-096Acid number in lubricants with potentiometric titration
Fresh as well as used petroleum products may contain acidic components as additives or degradation products. The acid number (AN) is a measure for the relative amount of acids present expressed as mg KOH per g sample. Moreover, AN is used as a quality parameter of lubricating oils both for assessing the quality of new formulations and as an indicator for the degradation of such formulations during service. The use of a pH electrode suitable for non-aqueous titrations ensures the reliable determination of the equivalence point. A flexible sleeve diaphragm facilitates its cleaning especially after use in heavily contaminated samples, such as in used engine oils. Using the correct electrode greatly increases the precision and reliability of the results. This Application Note describes the potentiometric determination of the acid number according to ASTM D664 and IP 177 using the pH electrode Solvotrode easyClean.
- AN-T-152Automatic determination of mercaptans in refinery products
Potentiometric titration with silver nitrate can be used for the determination of mercaptans in refinery products. This Application Note describes their automatic determination in a middle distillate sample (gas oil).