Приложения
- AB-204Oxidation stability of oils and fats – Rancimat method
This document outlines Rancimat testing for both liquid and solid food samples, including direct and PEG methods, for oxidation stability QC in the food industry.
- AB-280Automatic Karl Fischer water content determination with the 874 Oven Sample Processor
Generally speaking, the gas extraction or oven method can be used for all samples which release their water when they are heated up. The oven method is indispensable in cases in which the direct volumetric or coulometric Karl Fischer titration is not possible, either because the sample contains disruptive components or because the consistency of the sample makes it very difficult or even impossible to transfer it into the titration vessel.The present Application Bulletin describes automatic water content determination with the aid of the oven technique and coulometric KF titration, using samples from the food, plastic, pharmaceutical and petrochemical industry.
- AN-C-157Sodium and potassium in polyol using IC following inline matrix elimination
Polyols are important raw materials in polyurethane production. Contamination in the raw materials have a great influence on reactions and impair the quality of the end product. Alkali metals are particularly strong catalysts for linear or branched reactions. A rapid and precise method for their simultaneous determination is ion chromatography following Inline Matrix Elimination.
- AN-C-165Triethylamine in aqueous 1,3,5-trioxane solution with direct conductivity detection
1,3,5-trioxane is a heterocyclic compound formed by trimerization of formaldehyde. Trioxane is used for the production of polyformaldehyde plastics such as poly(oxymethylene) (POM) and solid fuels. Aqueous 1,3,5-trioxane solutions frequently contain trace triethylamine that requires quantification. This is performed on the Metrosep C 3 - 250/4.0 column with subsequent direct conductivity detection.
- AN-CIC-004Total and leachable concentration of halogens and sulfur in latex gloves using Combustion Ion Chromatography and a leaching test
Latex gloves are used in clean room environments in order to prevent contaminations. The use of gloves that release corrosive halogenides or sulfate is forbidden in nuclear power plants. The total content of halogen and sulfur is determined by means of Combustion Ion Chromatography. An eluate test is carried out to check the elutable percentage of halogens and sulfate from gloves. Sample preparation is comprised of preconcentration and matrix elimination (MiPCT-ME), as described in AN-S-304.Keyword: pyrohydrolysis
- AN-CIC-008Fluorine in polyisobutene using Metrohm Combustion IC
Polyisobutene (PIB) is an important raw material for a large range of products. Quality control requires the determination of the fluorine content. This task is easily done by Metrohm Combustion IC applying flame sensor technology and Inline Matrix Elimination.Keyword: pyrohydrolysis
- AN-CIC-032Chloride as an indicator of residual solvent presence in cellulose ester-based foil
Cellulose ester foils are produced using chlorinated solvents. The residual amount of the solvent used in production evaporates within a few days in ambient conditions. The residual solvent is determined by combustion IC, through the conversion of organically bound chlorine to chloride by pyrohydrolysis. The final product needs to be free of all chlorinated solvents. Therefore, critical contents of such compounds can be detected in quality control analysis. Application of MiPT in this study has enabled an automated and precise calibration out of a single standard.
- AN-CIC-035Halogens and sulfur in solid samples according to EN 17813
Organic halides must be monitored in the environment. Combustion ion chromatography (CIC) is used for accurate halogen analysis in solids following EN 17813:2023.
- AN-EC-002Reference electrodes and their usage
A reference electrode has a stable and well-defined electrochemical potential (at constant temperature), against which the applied or measured potentials in an electrochemical cell are referred. A good reference electrode is therefore stable and non-polarizable. In other words, the potential of such an electrode will remain stable in the used environment and also upon the passage of a small current. This application note lists the most used reference electrodes, together with their range of use.
- AN-EIS-005Electrochemical Impedance Spectroscopy (EIS) Part 5 – Parameter Estimation
In the application note AN-EIS-004 on equivalent circuit models, an overview of the different circuit elements that are used to build an equivalent circuit model was given. After identifying a suitable model for the system under investigation, the next step in the data analysis is estimation of the model parameters. This is done by the non-linear regression of the model to the data. Most impedance systems come with a data-fitting program. In this application note, the way NOVA is uses to fit the data is shown.