Sök
Produktfamiljer
Produktfamiljer (74)Produktmodeller
Produktmodeller (708)Applikationer
Applikationer (2279)Utbildning & webbinarier
Eventer (2)Elektroder
Elektroder (509)Kolonner
Kolonner (155)Accessories
Reservdelar (2212)Programvara
Software (270)Manualer och broschyrer
Dokument (2596)Annat innehåll
Innehåll (101)Support & service i särklass
Support & service (77)Inspirerande inblick i industrin
Inblick i industrin (175)Nyheter
Nyheter (86)Utbildning & webbinarier
Webinars (66)BWT-840000994
TacticID-N Plus Handheld Raman SpectrometerThe TacticID®-N Plus is a field-ready handheld Raman Spectrometer specifically designed for non-contact forensic analysis of narcotics, pharmaceutical drugs, cutting agents, and their precursors by law enforcement personnel.Featuring an intuitive workflow and touch screen, samples can be nondestructively analyzed through opaque and transparent packaging. The sample threat level is displayed prominently to the users, e.g. security staff, emergency services (such as law enforcement authorities), customs and border guards as well as bomb disposal squads, and hazmat teams, allowing them to act quickly with minimal sample contact. The TacticID-N Plus utilizes laboratory-proven Raman spectroscopy, which allows users to obtain identification of illicit substances in real time without ever compromising the integrity of the sample or the chain of evidence.TacticID-N Plus users have access to regular library updates in order to continuously maintain up-to-date identification capabilities and stay ahead of emerging narcotics.
STAT4000P
µStat 4000P Multi PotentiostatμStat 4000P is a portable Multi Potentiostat that can be applied for Voltammetric or Amperometric measurements, being able to perform up to 4 different independent measurements at the same time and including also a multichannel mode that allows you to work with up to 4 working electrodes sharing auxiliary and reference electrode. Li-ion Battery powered, it can be easily connected to a PC via USB or Bluetooth®.
2.1001.0120
OMNIS Basic Titrator with magnetic stirrerInnovative, modular potentiometric OMNIS Titrator for stand-alone operation or as the core of an OMNIS titration system for endpoint titration. Thanks to 3S Liquid Adapter technology, handling chemicals is more secure than ever before. The titrator can be freely configured with measuring modules and cylinder units and can have a rod stirrer added as needed. If required, the range of functions of the OMNIS Basic Titrator can be supplemented with a corresponding software function license. Control via PC or local network; Connection option for up to four additional titration or dosing modules for additional applications or auxiliary solutions; Connection option for one rod stirrer; Various cylinder sizes available: 5, 10, 20 or 50 mL; Liquid Adapter with 3S technology: Secure handling of chemicals, automatic transfer of the original reagent data of the manufacturerMeasuring modes and software options:; Endpoint titration: "Basic" function license; Endpoint and equivalence point titration (monotonic/dynamic): "Advanced" function license; Endpoint and equivalence point titration (monotonic/dynamic) with parallel titration: "Professional" function license;
2.1008.5010
Eco Titrator BiogasThe compact Eco Titrator with integrated magnetic stirrer and touch-sensitive user interface is ideal for routine analysis. It provides GLP-compliant results with minimum space requirements at all times (approx. DIN A4). The Eco Titrator Biogas offers you the complete package for determining the FOS/TAC value for monitoring your biogas reactor. The package contains the titrator, a 20 mL cylinder unit, a maintenance-free pH electrode with temperature sensor, and all buffer solutions and electrolytes for calibration and storage of the electrodes.
2.1012.0010
Main module Pick&Place LMain module for setting up an OMNIS Sample Robot Pick&Place in size L. This module is equipped with the main lift and one gripper. One module base and two rack bases are required to complete the setup. It must be equipped with sample racks, gripper fingers and clients, e.g., Pick&Place module or a pump module in order to use it to set up a functioning Sample Robot. The selection of these components proceeds in accordance with the application.
2.889.0020
889 IC Sample Center – coolThe 889 IC Sample Center – cool is the appropriate automation solution when you have only a very small amount of sample. In comparison with the 889 IC Sample Center, it possesses in addition a cooling function and is thus the ideal sample changer for biochemically relevant or thermally unstable samples.
2.921.1510
NIRS XDS Interactance OptiProbe AnalyzerRobust measurement system for the monitoring of reactions in technical centers and in pilot plants.The NIRS XDS Interactance OptiProbe Analyzer enables the simple and reliable monitoring of chemical reactions in technical centers and pilot plants. The method development and the scale-up of production processes are areas of application in which the NIRS XDS Interactance OptiProbe Analyzer supplies precise results regarding the identity and quality of a wide variety of samples. Whereas solids, strongly scattering liquids and slurries are measured with the reflection probe, the immersion probe is used to analyze aqueous products, clear liquids and solvents. The probe is connected to the analyzer through an optical fiber to enable secure measurements even under rough and/or dangerous conditions in the processing environment.
2.944.0010
944 Professional UV/VIS Detector VarioThe 944 Professional UV/VIS Detector Vario is the intelligent UV/VIS detector from Metrohm. It permits a secure and reliable quantification of substances active in the ultraviolet or visible range. Detection takes place via a Diode Array.
AUT.UVVIS.KIT.S
Autolab spectrophotometer kit UV/VISThe Autolab spectrophotometer kit UV/VIS consist of: UB spectrophotometer, light source, fiber cables and two type of DIO trigger cables.
STAT400
µStat 400 Bipotentiostat/GalvanostatμStat 400 is a portable BiPotentiostat/Galvanostat that can be applied for Voltammetric, Amperometric or Potentiometric measurements and can be used with one- or two-working electrodes configuration. Li-ion Battery powered, it can be easily connected to a PC via USB and Bluetooth®.
- 8.000.60458.000.6045Trace-level aliphatic amines in cationic pharmaceutical ingredients
The analytical challenge treated by the present work consists in detecting sub-ppb concentrations of low-molecular-weight amines in the presence of strongly retained cationic drugs by using ion chromatography (IC) with upstream inline coupled-column matrix elimination (CCME). In contrast to direct-injection IC, where the late elution of strongly retained drugs requires eluents with added acetonitrile, the CCME technique uses two preconcentration columns in series. In an «inverse matrix elimination step, cationic drug and target amines are trapped on a high-capacity and a very-high-capacity preconcentration column, respectively. During amine determination, a rinsing solution flushes the drug to waste. This significantly shortens the analysis time and improves sensitivity as well as selectivity. Besides the determination of monomethylamine in Nebivolol hydrochloride discussed here, the CCME technique is a promising tool for detecting further low-molecular-weight amines in a wide range of drugs.
- 8.000.60478.000.6047Fully automated potentiometric determination of the hydroxyl number (HN) according to ASTM E1899-08 and DIN 53240-2
Hydroxyl is an important functional group and knowledge of its content is required in many intermediate and end-use products such as polyols, resins, lacquer raw materials and fats (petroleum industry). The test method to be described determines primary and secondary hydroxyl groups. The hydroxyl number is defined as the mg of KOH equivalent to the hydroxyl content of 1 g of sample.The most frequently described method for determining the hydroxyl number is the conversion with acetic anhydride in pyridine with subsequent titration of the acetic acid released: H3C-CO-O-CO-CH3 + R-OH -> R-O-CO-CH3 + CH3COOH. However, this method suffers from the following drawbacks: - The sample must be boiled under reflux for 1 h (long reaction time and laborious, expensive sample handling) - The method cannot be automated - Small hydroxyl numbers cannot be determined exactly - Pyridine has to be used, which is both toxic and foul-smellingBoth standards, ASTM E1899-08 and DIN 53240-2, offer alternative methods that do not require manual sample preparation and therefore can be fully automated: The method suggested in ASTM E1899-08 is based on the reaction of the hydroxyl groups attached to primary and secondary carbon atoms with excess toluene-4-sulfonyl-isocyanate (TSI) to form an acidic carbamate. The latter can then be titrated in a non-aqueous medium with the strong base tetrabutyl- ammonium hydroxide (TBAOH). The method suggested in DIN 53240-2 is based on the catalyzed acetylation of the hydroxyl group. After hydrolysis of the intermediate, the remaining acetic acid is titrated in a non-aqueous medium with alcoholic KOH solution. The present work demonstrates and discusses an easy way to determine the hydroxyl number according to ASTM E1899-08 or DIN 53240-2 with a fully automated titrimetric system for a great variety of industrial oil samples.
- 8.000.60488.000.6048Fully automated determination of fluoride in blood samples
Sodium fluoride is used as a preservative in biological samples for alcohol analysis. All submitted blood samples, including those taken from vehicle drivers suspected of driving under the influence of liquor, have to be tested for adequate preservation prior to alcohol determination by gas chromatography. This is critical to ensure adequate sample preservation. Inadequate sample preservation may allow glycolysis and/or microorganism growth to produce ethanol.In the past this has been done by direct potentiometric measurement using a fluoride-selective electrode (F ISE), an ion meter and certified NaF standards. The sodium fluoride level was determined manually by dipping the electrode directly into the blood sample. Results were recorded manually. This poster describes two independent automated methods of analysis that allow the minimization of this tedious and time-consuming procedure.In the first one, the fluoride content in a blood aliquot is measured by direct potentiometric measurement after the addition of TISAB and deionized water. The second method employs the titration of the sample aliquot with La(NO3)3 after adding a buffer solution.
- 8.000.60518.000.6051PC-controlled dosing and liquid handling
The 800 Dosino controlled by tiamo™ or Touch Control can be used universally for dosing and liquid handling tasks in both the analytical laboratory or directly in the synthesis laboratory. This poster looks at three typical liquid handling applications, the synthesis of metal-organic compounds, the preparation of standards, and the determination of pharmaceutical ingredients.
- 8.000.60528.000.6052Quality assurance of biofuels
This poster provides an overview of ion chromatographic methods combined with inline sample preparation for the determination of anions and water-extractable cations in biofuels. In addition, the determination of the oxidation stability is described.
- 8.000.60538.000.6053Trace-level determination of perfluorinated compounds in water by suppressed ion chromatography with inline matrix elimination
This poster describes a simple and sensitive method for the determination of perfluorooctanoate (PFOA) and perfluorooctane sulfonate (PFOS) in water samples by suppressed conductivity detection. Separation was achieved by isocratic elution on a reversed-phase column thermostated at 35 °C using an aqueous mobile phase containing boric acid and acetonitrile. The PFOA and PFOS content in the water matrix was quantified by direct injection applying a 1000 μL loop. For the concentration range of 2 to 50 μg/mL and 10 to 250 μg/mL, the linear calibration curve for PFOA and PFOS yielded correlation coefficients (R) of 0.99990 and 0.9991, respectively. The relative standard deviations were smaller than 5.8%.The presence of high concentrations of mono and divalent anions such as chloride and sulfate has no significant influence on the determination of the perfluorinated alkyl substances (PFAS). In contrast, the presence of divalent cations, such as calcium and magnesium, which are normally present in water matrices, impairs PFOS recovery. This drawback was overcome by applying Metrohm`s Inline Cation Removal. While the interfering divalent cations are exchanged for non-interfering sodium cations, PFOA and PFOS are directly transferred to the sample loop. After inline cation removal, PFAS recovery in water samples containing 350 mg/mL of Ca2+ and Mg2+ improved from 90…115% to 93…107%.While PFAS determination of low salt-containing water samples is best performed by straightforward direct-injection IC, water rich in alkaline-earth metals are best analyzed using Metrohm`s Inline Cation Removal.
- 8.000.60558.000.6055Liquid handling applied to automated sample preparation in liquid chromatography
In routine chemical analysis, the predominant challenge involves a higher sample throughput, improved reproducibility, liquid handling flexibility and reduced personnel costs. In response to these requirements, the 872 Extension Module Liquid Handling in combination with the MagIC NetTM software and the well-proven Dosino technology expands the possibilities of inline sample preparation and opens up new fields of application. Among others, the module can be used, together with an optional mixing vessel, for pH adjustments, pre-column derivatizations, or the mixing of solutions.As a representative of an inline sample preparation technique, this poster describes the performance of precise dilutions. By using only one single stable standard solution, multi-point calibration curves can be automatically recorded by diluting a concentrated standard in an external vessel.
- 8.000.60578.000.6057Simultaneous determination of gamma-hydroxybutyric acid (GHB) and gamma-butyrolactone (GBL) in beverages
Psychoactive gamma-hydroxybutyrate (GHB) and its prodrug gamma-butyrolactone (GBL) are substances that are increasingly abused as date-rape and recreational (party) drugs. Since the non-controlled GBL converts into the illicit GHB both in-vivo and in-vitro, their legal distinction is of crucial importance.For the forensic determination of illegally added GHB and GBL in commonly consumed beverages, this work presents a simple and sensitive method that employs direct-injection ion chromatography combined with spectrophotometric detection. The method allows to trace GHB-GLB interconversion, whether in vivo or in vitro lactone cleavage or intramolecular GHB esterification, and thus complies with pertinent requirements of law enforcement agencies.
- 8.000.60588.000.6058Analysis of airborne particulate matter by PILS-IC
This study compares air sampling data obtained by a filter-based method including off-line manual filter extraction followed by ion chromatographic analysis with those gained by an automated Particle-Into-Liquid-Sampler coupled to an ion chromatograph (PILS-IC).PILS-IC is a straightforward instrument for aerosol sampling that provides near real-time measurements for long-term unattended operation and is thus an indispensable tool to monitor rapid changes in aerosol particle ionic composition.
- 8.000.60598.000.6059Determination of hazardous substances in electrical and electronic equipment
The Restriction of Hazardous Substances (RoHS) Directive 2002/95/EC stipulates maximum limits for the hazardous metals cadmium, lead and mercury as well as the hexavalent chromium and the brominated flame retardants in electrical and electronic products. To ensure compliance, reliable analysis methods are required.This poster deals with the wet-chemical determination of trace concentrations of the six RoHS-restricted substances in a wide variety of materials including metals, electrotechnical components, plastics and wires. After sample preparation according to IEC 62321, the metals lead, cadmium and mercury are best determined by anodic stripping voltammetry (ASV) and the flame retardants PBB and PBDE are quantified by direct-injection ion chromatography (IC) using spectrophotometric detection. Chromium(VI) can be determined either by adsorptive stripping voltammetry (AdSV) or IC. Both methods are very sensitive and meet prescribed RoHS limits.
Metrohm Processanalysatorer
Metrohm Processanalys har sedan långt tillbaka utformat och erbjudit lösningar för processanalys, processtyrning och processövervakning, idealiska för processindustrin.
Processanalysatorer
Avancerade processanalysatorer för industriella analyser, inline-, online- och atline-: petrokemiska, energi-, halvledar-, metall-, papper-, gruv- och (avlopps)vattenapplikationer.
Metrohm Processanalys Kvalitetsservice
Kvalitetsservice för Metrohm Processanalysatorer
Förkonditioneringssystem för prover
Vitbok: Använda kemisk analys online för att optimera produktionen av propylenoxid
Lär dig hur du optimerar produktionen av PO (propylenoxid) med hjälp av processanalys istället för laboratorieanalyser
Vitbok: Manuell versus automatiserad titrering: fördelar och fördelar med att byta
Ladda ner vår vitbok och lär mer om fördelarna med automatiska titratorer jämfört med manuella titreringsinställningar.
USP-rekommendationer: Övervinner manuell titrering
USP har publicerat rekommendationer om hur man omvandlar manuella titreringsmetoder till automatiska titreringsmetoder för farmaceutiska tester. Ladda ner vitboken och lär mer om hur du konverterar dina manuella titreringsmetoder och moderniserar dina farmaceutiska analystester.
Programvarusökare
Find Metrohm software for titration, IC, VA/CVS, stability measurement, electrochemistry, spectroscopy, and more.
Kolonnsökare
Find analytical, trap, and guard columns for the determination of anions and cations.
Tillbehörssökare
Find dosing units, tubes, glassware, beakers, and other accessories and spare parts.
6.06008.201
Function license for OMNIS Sample Robot S – NIRFunction license for utilization of the command parameters for the OMNIS Sample Robot S – NIR.
6.06008.202
Function license for OMNIS Sample Robot M – NIRFunction license for utilization of the command parameters for the OMNIS Sample Robot M – NIR.
6.06071.020
MIRACal DS USB StickUser-friendly software developed primarily for downloading and printing reports, analyzing data, creating spectral libraries, collecting data and managing users.
6.06073.000
Raman Spectral USP LibraryThe USP library for the MIRA M-3/P contains more than 500 certified secondary USP standards for pharmaceutical API's and excipients.
6.6053.030
797 VA Computrace Software CD 1.3Control and evaluation software for 797 VA Computrace. For the following operating systems: Windows ® 2000, Windows ® XP Professional, Windows ® Vista (32-bit) and Windows ® 7 (32-bit).
6.6055.001
Food PAC (German)The know-how package for the titrimetric/potentiometric analysis of foods.
6.6055.003
Food PAC (English)The know-how package for the titrimetric/potentiometric analysis of foods.
6.6056.021
tiamo™ 2.X multi: 1 additional licenseOptional license for tiamo™ multi. For ordering the serial number of tiamo™ multi is required!
6.6056.022
tiamo™2.X multi: 5 additional licensesOptional license for tiamo™ multi. For ordering the serial number of tiamo™ multi is required!
6.6056.023
tiamo™ 2.X multi: 10 additional licensesOptional license for tiamo™ multi. For ordering the serial number of tiamo™ multi is required!
ITO10
Optically Transparent ITO Screen-Printed ElectrodeOptically Transparent ITO Screen-Printed Electrode. Specially designed for Spectroelectrochemical applications.
P10
Optically Transparent PEDOT Screen-Printed ElectrodeOptically Transparent PEDOT Screen-Printed Electrode. Specially designed for ElectroChemiLuminiscence or Spectroelectrochemical applications.
AUTR10
Optically Transparent Gold ElectrodeOptically Transparent Gold Electrode. Specially designed for Spectroelectrochemical applications.
AL10
Thick Film Aluminium Electrode (Aux.:C; Ref.:Ag) / Individually packagedThick Film Aluminium Electrode (Aux.:C; Ref.:Ag) / Individually packaged
CR10
Thick Film Chromium Electrode (Aux.:C; Ref.:Ag) / Individually packagedThick Film Chromium Electrode (Aux.:C; Ref.:Ag) / Individually packaged
MO10
Thick Film Molybdenum Electrode (Aux.:C; Ref.:Ag) / Individually packagedThick Film Molybdenum Electrode (Aux.:C; Ref.:Ag) / Individually packaged
PB10
Thick Film Lead Electrode (Aux.:C; Ref.:Ag) / Individually packagedThick Film Lead Electrode (Aux.:C; Ref.:Ag) / Individually packaged
SB10
Thick Film Antimony Electrode (Aux.:C; Ref.:Ag) / Individually packagedThick Film Antimony Electrode (Aux.:C; Ref.:Ag) / Individually packaged
SN10
Thick Film Tin Electrode (Aux.:C; Ref.:Ag) / Individually packagedThick Film Tin Electrode (Aux.:C; Ref.:Ag) / Individually packaged
TA10
Thick Film Tantalum Electrode (Aux.:C; Ref.:Ag) / Individually packagedThick Film Tantalum Electrode (Aux.:C; Ref.:Ag) / Individually packaged
- 25 jan. 2021Fast determination of acid and base number by thermometric titration
Determine the acid number and base number in petroleum products quickly and reliably with thermometric titration.
- 22 feb. 2021Recipes with Raman
Analys av fenolföreningar, fungicider, fruktmognadsprocessen, syntetiska färgämnen, köttets färskhet, ätliga oljors renhet och oljors värmestabilitet med Raman-spektroskopi.
- 9 aug. 2021From corn to ethanol: improving the fermentation process with NIRS
Förbättrad jäsning vid bioetanolproduktion med analys av nära infraröd spektroskopi.
- 20 sep. 2021Coffee: serving up chemistry in every cup
The origins of coffee and how to determine the key quality parameters.
- 13 sep. 2021Frequently asked questions for beverage analysis with ion chromatography
Blogginlägg om analys av drycker, t.ex. vatten, mjölk, kaffe, juice, läskedrycker, öl och vin med jonkromatografi.
- 15 mars 2021Multiparameter analysis in fertilizers by thermometric titration
Varför analysera gödselsammansättningen och bestämma kalium, fosfor, svavel, ammoniumkväve och urea.
- 6 apr. 2021Easy moisture determination in fertilizers by near-infrared spectroscopy
- 22 apr. 2021Decarbonizing chemical processes with Thor
Avkolning av den kemiska industrin med en hydreringsreaktor som använder vatten som vätgaskälla.
- 7 dec. 2020Introduction to Analytical Instrument Qualification – Part 1
- 11 maj 2020Titer determination in Karl Fischer titration
Hur man bestämmer titern i Karl Fischer-titrering med vattenstandard, fast vattenstandard eller rent vatten.
6.01032.510
Metrosep A Supp 17 S-Guard/4.0The Metrosep A Supp 17 S-Guard/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. The guard column is simply connected to the separation column using capillary connections. No tools are required.
6.01032.530
Metrosep A Supp 17 S-Guard - 50/4.0The Metrosep A Supp 17 S-Guard 50/4.0 reliably protects the Metrosep A Supp 17 analytical separation columns against contamination. The guard column is simply connected to the separation column using capillary connections. No tools are required.
6.01051.600
Metrosep C 6 Guard/2.0The Metrosep C 6 Guard/2.0 contains the C 6 column material and is used to protect against particles and contamination. This considerably lengthens the service life of the analytical separation column. The Metrosep C 6 Guard/2.0 works according to the "On Column Guard System" and is screwed directly onto the respective separation column with virtually no dead volume.
6.01053.500
Metrosep C Supp 2 Guard/4.0The Metrosep C Supp 2 Guard/4.0 contains the C Supp 2 column material and is used to protect Metrosep C Supp 2 cation columns. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column. The Metrosep C Supp 2 Guard/4.0 also works based on the "On Column Guard System" and is screwed directly onto the separation column with virtually no dead volume.
6.01070.500
MetroSil RP 3 Guard/4.0The MetroSil RP 3 Guard/4.0 is used to protect the MetroSil RP 3 - 150/4.0 against contaminations from particles and bacteria.
6.01090.600
Metrosep Carb 2 Guard/2.0The Metrosep Carb 2 Guard/2.0 microbore guard column effectively removes contaminations, thus protecting the analytical separation column. The design of the guard column has been selected in such a way that its influence on the chromatographic separation can be ignored.
6.1005.020
PRP-X100 guard column cartridge/4.0For protecting Hamilton PRP-X100 columns.The cartridge efficiently removes contamination in the form of particles due, for example, to the growth of bacteria or algae.
6.1005.250
Metrosep Organic Acids Guard/4.6The Metrosep Organic Acids Guard/4.6 effectively removes contamination, thus protecting the analytical separation column.
6.1005.340
Metrosep A Supp 1 Guard/4.6The Metrosep A Supp 1 Guard/4.6 protects the Metrosep A Supp 1 - 250/4.6 separation column securely against contaminations from particles and bacteria.
6.1006.500
Metrosep A Supp 5 Guard/4.0The Metrosep A Supp 5 Guard/4.0 reliably protects the Metrosep A Supp 5 and 7 IC anion columns against contamination from the sample or the eluent.It contains the same separation material as the Metrosep A Supp 5, is also made of PEEK, and is screwed directly onto the respective separation column with virtually no dead volume ("On Column Guard System"). The guard column prolongs the service life of the analytical column, with practically no influence on its chromatographic separating efficiency. The economical price and simple handling make using the A Supp 5 Guard/4.0 highly recommended.
MAGNETOEC
MagnetoElectroChemistry supportMagnetoElectroChemistry support with variable magnet pole gaps that allows performing magnetoelectrochemical experiments with Screen-Printed Electrodes and also with conventional electrochemical cells.
PDNW
Palladium NanowiresPalladium Nanowires produced via the electrochemical deposition on an alumina template. Our Palladium Nanowires have an average diameter of 150-250 nm and an average length of 10-16 µm.- Available in 1.5 mL and 4.5 mL.
MAGNET
Magnetic support for Screen-Printed ElectrodesMagnetic support for Screen-Printed Electrodes. Recommended to perform analysis with magnetic beads
PTNW
Platinum NanowiresPlatinum Nanowires produced via the electrochemical deposition on an alumina template. Our Platinum Nanowires have an average diameter of 150-250 nm and an average length of 10-16 µm. - Available 1.5 and 4.5 mL.
PVCTUBE
PVC Tube for Peristaltic Pump - Several DiametersPVC Tube for Peristaltic Pump - Several Diameters. Includes: 3 tubes of 0.899 inner diameter, 1.143 mm inner diameter, 1.422 mm inner diameter and 1.651 mm inner diameter
RAMANCELL
Raman Cell for Screen-Printed ElectrodesBlack teflon reflection cell for performing Raman Spectroelectrochemistry with screen-printed electrodes in combination with ref. RAMANPROBE.
MAGNET8X
Magnetic support for format 8X Screen-Printed ElectrodesMagnetic support for format 8X Screen-Printed Electrodes. Recommended to perform analysis with magnetic beads
PTAUNINW
Platinum Gold Nickel NanowiresPlatinum-gold-nickel (Pt-Au-Ni) Nanowires produced via the electrochemical deposition on an alumina template. Our Pt-Au-Ni Nanowires have an average diameter of 150-250 nm and an average length varying in two ranges: Pt (1.5 µm) - Au (5 µm) - Ni (2 µm) or Pt (1.5 µm) - Au (2 µm) - Ni (2 µm). - Available 1.5 mL and 4.5 mL.
TFIBER-VIS-UV
Transmission fiber VIS-UVTransmission fiber VIS-UV designed to perform transmission experiments suitable to work with our Transmission Cell for transparent Screen-printed electrodes or with any conventional cell
TLFCL-REFLECELL
Spectroelectrochemical Reflection Cell for Thin-Layer Flow-Cell Screen-Printed ElectrodesCell for performing spectroelectrochemical measurements in flow conditions in combination with the TLFCL-CIR format Screen-Printed Electrodes, the suitable fittings and ref. RPROBE-VIS-UV.
- 9 sep. 2020Mira Protective Boot: Extra skydd för extrema förhållanden
- 12 juni 2024Potassium analysis with ion chromatography according to USP testing methods
In 2010 the United States Pharmacopeia (USP) began modernizing their monographs. As a part of this effort, test methods for the quantification of potassium now include ion chromatography. Ion chromatography is a viable alternative method for the analysis of potassium. Compared to other potassium analysis methods, ion chromatography has the advantage of analyzing multiple cationic species concurrently.
- 6 aug. 2024Updated m-oem website emphasizes Metrohm components and capabilities
m-oem, the OEM division of Metrohm, has completed a significant upgrade to their website. Composed of B&W Tek, DropSens, Innovative Photonic Solutions (IPS) and Metroglas, m-oem offers the components found in Metrohm’s world-class analytical instruments to customers for integration and customization projects.
- 22 jan. 2025New subsidiaries: Metrohm Korea and Metrohm Portugal
Metrohm is pleased to welcome two new members to the Metrohm family: Metrohm Korea and Metrohm Portugal. These new subsidiaries allow us to strengthen our presence in these two markets and provide the best possible service and support to our customers.
- 14 feb. 2025New Regional Support Center for West, Central, and East Africa
Metrohm Central Africa Ltd. provides application, technical, and service support for customers in West, Central, and East Africa.
- 27 jan. 2025Stay up-to-date: Subscribe to our news, events, and blog
More than 900 people read our blog every day. Don't miss out – subscribe now to our blog, news, and events. Receive the latest updates directly in your inbox.
- 8.000.53008.000.5300Brochure: TitrIC flex – All you need for comprehensive water analysis
TitrIC flex is the most flexible, reliable and easy to use system for water analysis ever. Combining titration, directmeasurement, and ion chromatography (IC), TitrIC flex allows you to determine the complete range of ions typically present in water. The present brochure gives you an overview about Metrohm's new TitrIC flex system.
English
- 8.000.53128.000.5312Electrode shaft for screen-printed electrodes – Screen-printed electrodes for VA Analysis
With the electrode shaft, you can now use screen-printed electrodes (SPE) in any Metrohm VA Stand. Whether you aredoing voltammetric trace analysis or you want to explore new application fields with your own modified sensor, the electrode shaft allows simple use of SPEs.
English
- 8.000.53138.000.5313Brochure: Wastewater Analysis – Expertise in water and wastewater analysis
If the concentration of organic contaminants is too high, they may interfere with many industrial processes, leadingto problems. As a leading manufacturer of instruments for chemical analysis, Metrohm Process Analytics offers state-of-the art systems and complete solutions that allow easy and cost-saving monitoring of your water samples.
English
Andra språk
- 8.000.53148.000.5314Brochure: Instruments for electrochemical research
Metrohm Autolab sets the standard for electrochemistry instrumentation. The instruments are suitable for most application areas including: corrosion, energy, environmental, sensors, and solar. This brochure presents the Metrohm Autolab product portfolio.
English
- 8.000.53158.000.5315Brochure: Metrohm Process Analytics Quality Service
Metrohm Quality Service encompasses more than just analyzer service. Metrohm Quality Service is primarily about trust. Trust that someone will be there for you when you need advice, service or support. Trust that you can rely on the service and maintenance work performed on your analyzers. Trust in the application support offered by experts who take their time to address your requirements. Metrohm Quality Service stands for service that simplifies your daily work in a 24/7 process environment, makes it safer, and, above all, more predictable.
English
Andra språk
- 8.000.53168.000.5316Brochure: Border security with Metrohm identification systems – Detect hazards fast and accurately at the touch of a screen
Customs plays a crucial role in border security. Challenges are diverse, ranging from counterfeits to illegal substances and imports all the way to explosives and toxic substances. With Mira handheld identification systems from Metrohm, you are prepared to detect them all – safely and accurately, at the touch of a screen.
English
- 8.000.53238.000.5323Brochure: Spectroelectrochemistry within everyone’s reach – When combining two techniques became the perfect solution for your research
Advanced instruments for getting the most of your experiments through a dedicated and easy to use software. A completesolution for obtaining synchronized optical and electrochemical data. Spectra are obtained while electrochemical processes are taken place in the system under study. Find more information about typical applications and key benefits in this brochure.
English
- 8.000.53258.000.5325Brochure: Water Content Analysis
Metrohm is recognized as the global market leader in the field of titration. Karl Fischer titration is one of the most widely used analytical methods for moisture analysis in routine laboratory work, and it provides precise analytical results. To increase sample throughput, productivity, and product quality, water determination can be easily implemented directly inline thanks to near-infrared spectroscopy (NIRS). The results of the laboratory analysis are used to create an accurate prediction model for the NIR spectrometer. Inline moisture analysis with NIRS analytical results are generated in near real-time every second without sampling or using chemicals.
English
Andra språk
- 8.000.53268.000.5326Brochure: Metrohm Autolab Impedance Station for Battery Applications – Versatility and efficiency for your battery research
The Autolab Impedance Station expands your research capability without complicating it. Easy to integrate into your existing lab setup, with the Autolab Impedance Station you can improve your battery characterization with more in-depth and accurate data. This brochure provides insight into benefits, applications, and specifications of the Autolab Impedance Station.
English
- 8.000.53278.000.5327Brochure: Higher methane yield, more profit – Simple, fast, and inexpensive FOS/TAC determination in biogas plants
The FOS/TAC ratio is widely accepted as a key parameter for monitoring and controlling biogas plants. If the value does not lie between 0.3 and 0.4, the methane yield and thus the profitability of your business will decrease. To ensure optimum methane yield and maximum profitability, you can monitor the FOS/TAC ratio very easily with an Eco Titrator from Metrohm.
English
Andra språk