Продуктовые линейки
Продуктовые линейки (68)Модели
Модели (722)Методики
Методики (2249)Тренинги и вебинары от экспертов
События (5)Электроды
Электроды (527)Колонки
Колонки (155)Accessories
Запчасти (2342)Программное обеспечение
Software (290)Мануалы и брошюры
Документы (2515)Другой контент
Контент (111)Вдохновляющие отраслевые идеи
Отраслевые исследования (180)Industries
Industries (50)Новости
Новости (53)Превосходные сервис и поддержка
Support & service (79)Тренинги и вебинары от экспертов
Вебинары (83)2.930.8030
Continuous IC Package DRThe Continuous IC Package DR enables the analysis of anions with hydroxide eluents. It comprises all required components, e.g., the 930 Compact IC Flex Oven/SeS/Deg, the IC Conductivity Detector MB, the 948 Continuous IC Module, the 858 Professional Sample Processor pump, the Dosino regeneration (DR), and the MagIC Net Software.
2.930.8040
Continuous IC Package PPThe Continuous IC Package PP enables the analysis of anions with hydroxide eluents. It comprises all required components, e.g., the 930 Compact IC Flex Oven/SeS/PP/Deg, the IC Conductivity Detector MB, the 948 Continuous IC Module, the 858 Professional Sample Processor pump, and the MagIC Net Software.
2.930.9030
Metrohm Combustion IC Manual - QuartzThe Metrohm Combustion IC Manual - Quartz package enables the analysis of halogens and sulfur in flammable samples of all types using inline combustion digestion (pyrohydrolysis) with subsequent ion chromatography determination (Combustion IC). It comprises all required components, such as the Combustion Oven (TEI) from Trace Elemental Instruments (2.0136.0600), the quartz combustion tube (6.07311.100), the 920 Absorber Module, the 930 Compact IC Flex Oven/SeS/PP/Deg, and the MagIC Net software. If necessary, the Metrohm Combustion IC package can be supplemented with one of the following Autosamplers: Solid Autosampler CIC (TEI), Liquid Autosampler CIC (TEI) or GLS Sampler CIC (TEI).
2.930.9040
Metrohm Combustion IC Manual - CeramicThe Metrohm Combustion IC Manual - Ceramic package enables the analysis of halogens and sulfur in flammable samples of all types using inline combustion digestion (pyrohydrolysis) with subsequent ion chromatography determination (Combustion IC). It comprises all required components, such as the Combustion Oven (TEI) from Trace Elemental Instruments (2.0136.0600), the ceramic combustion tube (6.07311.110), the 920 Absorber Module, the 930 Compact IC Flex Oven/SeS/PP/Deg, and the MagIC Net software. If necessary, the Metrohm Combustion IC package can be supplemented with one of the following Autosamplers: Solid Autosampler CIC (TEI), Liquid Autosampler CIC (TEI) or GLS Sampler CIC (TEI).
2.940.1100
940 Professional IC Vario ONEThe 940 Professional IC Vario ONE is the intelligent IC instrument for applications without suppression. The instrument can be used with any separation and detection methods.Typical areas of application:Anion and cation determinations without suppression; Analyses with UV/VIS detection with or without post-column derivatization; Applications with amperometric detection (e.g., sugar analysis); Trace analysis for cations with MiPCT;
2.940.1110
940 Professional IC Vario ONE/Prep 1The 940 Professional IC Vario ONE/Prep 1 is the intelligent IC instrument without suppression in combination with MetrohmInline Sample Preparation, e.g., Inline Ultrafiltration or Inline Dialysis. The instrument can be used with any separation and detection methods.Typical areas of application:Anion and cation determinations without suppression after Inline Ultrafiltration or Inline Dialysis; UV/VIS applications after Inline Ultrafiltration or Inline Dialysis; Applications with amperometric detection after Inline Ultrafiltration or Inline Dialysis;
2.940.1120
940 Professional IC Vario ONE/Prep 2The 940 Professional IC Vario ONE/Prep 2 is the intelligent IC instrument without suppression in combination with Metrohm Inline Sample Preparation, e.g., Inline Matrix Elimination or Inline Calibration. The instrument can be used with any separation and detection methods.Typical areas of application:Anion and cation determinations without suppression after Inline Matrix Elimination; Ultratrace analysis for cations with Inline Calibration;
2.940.1140
940 Professional IC Vario ONE/HPGThe 940 Professional IC Vario ONE/HPG is the intelligent IC instrument without suppression with binary high-pressure gradient. It can be extended with the 942 Extension Modules to up to a quaternary gradient system. The instrument can be used with any separation and detection methods.Typical areas of application:Carbohydrate analysis with pulsed amperometric detection (PAD) after gradient elution; Gradient applications with UV/VIS detection with or without post-column derivatization;
2.940.1150
940 Professional IC Vario ONE/LPGThe 940 Professional IC Vario ONE/LPG is the intelligent IC instrument without suppression with low-pressure gradient. The instrument can be used with any separation and detection methods.Typical areas of application:Carbohydrate analysis with pulsed amperometric detection (PAD) after gradient elution; Gradient applications with UV/VIS detection with or without post-column derivatization;
2.940.1200
940 Professional IC Vario ONE/ChSThe 940 Professional IC Vario ONE/ChS is the intelligent IC instrument with chemical suppression. An 800 Dosino can be used for the regeneration of the suppressor. The instrument can be used with any separation and detection methods.Typical areas of application:Anion determinations with chemical suppression and conductivity detection; Organic acids with ion-exclusion chromatography and inverse suppression;
- AN-U-009AN-U-009Iodate, chlorite, bromate, and nitrite by suppressed ion chromatography using a post-column reaction (PCR) and UV/VIS detection
Determination of iodate, chlorite, bromate, and nitrite using suppressed anion chromatography with UV/VIS detection after post-column reaction.
 - AN-U-022AN-U-022Traces of nitrite in mineral water with UV detection
Determination of nitrite in mineral water using anion chromatography with UV detection.
 - AN-U-028AN-U-028Salicylic acid impurity in aspirin tablets according to the USP method
Determination of salicylic acid and acetylsalicylic acid according to USP 28-NF 23 (second supplement) using RP chromatography with UV detection.
 - AN-U-034AN-U-034Chromatographic purity determination of ibuprofen according to USP
Determination of valerophenone and ibuprofen according to USP 28-NF 23 (second supplement) using RP chromatography with UV detection.
 - AN-U-055AN-U-055Amino acids in cell culture growth medium applying UV/VIS detection after post-column reaction with ninhydrin at 120 °C
Cell culture growth media contain all required components to keep cells alive. Here the amino acid composition is analyzed. A binary gradient separates in this example amino acids. The post-column reaction with ninhydrin requires a temperature of 120 °C, while the samples need to be cooled for stability.
 - AN-U-059AN-U-059Transition metals in feedwater using post-column reaction and subsequent UV/VIS detection
Feedwater for steam generation in boiling water reactors (BWR) needs to be analyzed for corrosion products. Presence of transition metals, mainly nickel and iron, indicates corrosion problems. Traces of these ions are determined using Inline Preconcentration (MiPCT). After separation, post-column reaction with 4-(2-pyridylazo)resorcinol (PAR) allows VIS detection at 510 nm.
 - AN-U-066AN-U-066Determination of EDTA, HEDTA and DTPA according to EN 13368-1
Complexing agents are used in fertilizers to bind trace nutrients such as cobalt, iron, manganese, etc. EN 13368-1 describes the determination of EDTA, HEDTA, and DTPA. As sample preparation, Fe3+ is added to build complexes with the three agents. The complexes are separated on an anion-exchange column and detected by UV/VIS after addition of perchloric acid.
 - AN-U-072AN-U-072Speciation of vanadium(IV) and vanadium(V) as EDTA complexes in Benfield solution applying UV/VIS detection
The Benfield Process is a well known procedure to remove H2S and CO2 from petroleum and industrial gases. Vanadium pentoxide is added as a corrosion inhibitor and is most effective in a certain V(IV)/V(V) ratio. Therefore, speciation and determination of V(IV) and V(V) is important. This speciation is easily achieved on A Metrosep A Supp 5 - 50/4.0 column with EDTA as an eluent and UV/VIS detection at 282 nm.
 - AN-U-016AN-U-016Caffeine in cola soft drinks
Determination of caffeine in a cola soft drink using RP chromatography with UV/VIS detection.
 - AN-U-033AN-U-033Assay of theophylline tablets according to the USP method
Determination of theophylline and theobromine according to USP 28-NF 23 (second supplement) using RP chromatography with UV detection.
 
DRP-PW-4XIDEAU20-U50
Multi-interdigitated Gold Electrode / 20 microns lines and gaps / Plastic White SubstrateThese multi-electrodes are formed by four interdigitated gold electrodes in one piece. The interdigitated configuration improves the detection limits and sensitivity. The dimensions of the bands/gaps are 20 μm.
DRP-PW-4XIDEAU30-U50
Multi-interdigitated Gold Electrode / 30 microns lines and gaps / Plastic White SubstrateThese multi-electrodes are formed by four interdigitated gold electrodes in one piece. The interdigitated configuration improves the detection limits and sensitivity. The dimensions of the bands/gaps are 30 μm.
DRP-PW-4XIDEAU40-U50
Multi-interdigitated Gold Electrode / 40 microns lines and gaps / Plastic White SubstrateThese multi-electrodes are formed by four interdigitated gold electrodes in one piece. The interdigitated configuration improves the detection limits and sensitivity. The dimensions of the bands/gaps are 40 μm.
DRP-PW-4XIDEAU50-U50
Interdigitated Gold Electrode / 50 microns lines and gaps / Plastic White SubstrateThese multi-electrodes are formed by four interdigitated gold electrodes in one piece. The interdigitated configuration improves the detection limits and sensitivity. The dimensions of the bands/gaps are 50 μm.
DRP-PW-4XIDEAU60-U50
Multi-interdigitated Gold Electrode / 60 microns lines and gaps / plastic white substrateThese multi-electrodes are formed by four interdigitated gold electrodes in one piece. The interdigitated configuration improves the detection limits and sensitivity. The dimensions of the bands/gaps are 60 μm.
DRP-PW-IDEAU50-U50
Interdigitated gold electrode over white plastic substrateGold interdigitated electrodes made on white flexible plastic substrate with dimension for bands/gaps of 50 µm. The interdigitated configuration enhances sensibility and detection limits.
DRP-PW-IDEPD50-U50
Interdigitated palladium electrode over white plastic substratePalladium interdigitated electrodes made on white flexible plastic substrate with dimension for bands/gaps of 50 µm. The interdigitated configuration enhances sensibility and detection limits.
DRP-PW-PD10-U20
Thin Film Palladium electrode (Aux.: C; Ref.: Ag) / Plastic substrateDRP-UA10-U50
Uric acid sensorSuitable for the determination of uric acid
DRP-X4410-U75
Dual screen-printed Co-Phthalocyanine/Carbon working electrodes
6.07401.030
Holder OMNIS NIR, cuvette, 5 mmCuvette holder for the OMNIS NIR Analyzer for 5 mm quartz cuvettes (6.7401.220).
6.07401.040
Holder OMNIS NIR, cuvette, 10 mmCuvette holder for the OMNIS NIR Analyzer for 10 mm quartz cuvettes (6.7401.230).
6.07401.050
Holder OMNIS NIR, vial, 2 mmVial Holder for the OMNIS NIR Analyzer for 2 mm disposable vials (6.7402.070).
6.07401.060
Holder OMNIS NIR, vial, 4 mmVial Holder for the OMNIS NIR Analyzer for 4 mm disposable vials (6.7402.250).
6.07401.070
Holder OMNIS NIR, vial, 8 mmVial Holder for the OMNIS NIR Analyzer for 8 mm disposable vials (6.7402.240).
6.07401.080
Holder OMNIS NIR, vial, 10 mmVial Holder for the OMNIS NIR Analyzer for 10 mm disposable vials (6.7402.100).
6.07401.100
Holder OMNIS NIR, flow-through cellsCuvette holder for the OMNIS NIR Analyzer for flow-through cells(6.7401.300; 6.7401.310; 6.7401.320; 6.7401.330; 6.7401.340).
6.07401.110
Flow-through connector set, 1/8"Connection set for flow-through cells with an OMNIS Sample Robot.Contains flangeless sleeve 1/8", 10 pcs., Flangeless fitting with nut, 1/8", 10 pcs. and FEP tubings 1/8" x 1.59 mm, 4 pcs.
6.07401.320
Flow-through cell, 2 mmFlow quartz cuvettes with an optical path length of 2.0 mm suitable for near-infrared spectroscopy (NIRS) analyses.Compatible with:Holder OMNIS NIR, flow-through cell (6.070401.100);
6.07401.330
Flow-through cell, 2.5 and 5 mmFlow quartz cuvettes with quartz glass window and two optical path lengths (2.5 mm or 5.0 mm) suitable for near-infrared spectroscopy (NIRS) analyses.Compatible with:Holder OMNIS NIR, flow-through cell (6.070401.100)