Aplicações
- 8.000.6097TP screen printed ethanol sensor (EN)
Non-enzymatic ethanol sensor based on a nanostructured disposable screen-printed electrode.
- 8.000.6098Determination of cobalt content, solids content, relative density and viscosity in paint driers using Vis-NIR spectroscopy.
The poster shows the use of Vis-NIR spectroscopy for the simultaneous quantification of cobalt content, solids content, relative density and viscosity in paint driers as an outstanding alternative to conventional wet chemical laboratory methods. The advantages of the expanded wavelength range over the visible range become clear in this application: the visible range (400 – 780 nm) correlates directly with the cobalt content; the NIR range (780 – 2500 nm) is used for determining the chemical and physical parameters.
- 8.000.6101Analysis of Anions and Oxoanions using Ion Chromatography Mass Spectrometry (IC-MS)
Ion chromatography tackles difficult separation problems of various ionic species and typically works with conductivity detection. Mass detection as a secondary independent detector significantly lowers the detection limits and confirms the identity of analytes even when coeluting. This poster describes how the combination of IC-MS and automated sample preparation techniques cope with the analysis of anions and oxoanions in challenging matrices such as soil or explosion residues.
- 8.000.6102Ion chromatography – the all-rounder for pharmaceutical analysis
Pharmaceutical analysis guarantees drug safety by providing information on the identity, content, quality, purity, and stability of pharmaceutical products using analytical chemistry. Ion chromatography (IC) offers a broad range of pharmacopeia-compliant applications for quality control, monitoring, and improving drug manufacturing. As a very accurate and versatile technique, IC meets the requirements of many pharmaceutical applications. IC is a USP-accepted standard method for the determination of active pharmaceutical ingredients (APIs), excipients, impurities, pharmaceutical solutions as well as pharmaceutical starting materials, finished pharmaceutical products (FPPs) and even body fluids. This poster describes some typical examples.
- 8.000.6103Speciation of Cr(III) and Cr(VI) by IC-ICP-MS and Empower 3
This poster demonstrates the feasibility of coupling a Metrohm IC system to a PerkinElmer NexION ICP-MS, operated under Empower 3 Software. Using a Metrosep Carb 2 column, the chromatographic separation of both species was achieved with a high resolution. Low background and high sensitivity allow determination in the low ng/L range. Optimal separation and full complexation of Cr(III) is already possible with EDTA concentrations from 40 μmol/L in low matrix solutions and may need to be increased depending on the sample matrix. Handling of the system was easy and user friendly. It was shown that speciation of Cr(III) and Cr(VI) can be carried out on this system utilizing a professional data system for acquisition, processing, and reporting.
- 8.000.6105Selective and Sensitive determination of Zinc in Various OTC formulations as per USP <591>
This poster presented jointly with USP at AAPS meeting shows the new USP method for zinc as per <591> using Ion Chromatography which is highly selective and sensitive. Selectivity is achieved by separation and further improved with PCR reaction. Sensitivity and wide linear quantification limit make the new USP method ideal for QA/QC. Automated PCR delivery makes the overall method performance easy to validate.
- 8.000.6106Potassium Assay in OTC Drug Products by Ion Chromatography
This poster presented jointly with USP at AAPS meeting shows, that we successfully developed and validated a single IC procedure for potassium assay and identification in potassium bicarbonate and potassium chloride for effervescent oral suspension. The optimized chromatographic conditions could be used for other cationic impurities, such as magnesium, calcium, sodium, and ammonium in potassium bicarbonate and potassium chloride for effervescent oral suspension. Single chromatographic method for assay and identification simplifies the overall QA/QC workflow.
- 8.000.6107USP Modernization Initiative: Ionic Impurities in Drug Substances by Ion Chromatography
This poster presented jointly with USP at AAPS meeting shows, that we successfully validated an IC method to determine chloride and sulfate in drug substances, potassium bicarbonate and potassium carbonate. The proposed IC method overcomes limitations of the turbidimetry/visual comparison methods.
- 8.000.6108Comparative Study of Moisture Analysis Techniques on Cannabis
Moisture in cannabis impacts potency and must be accurately determined. Loss on drying (LOD) is the most popular method for determining moisture in cannabis. Unfortunately, this technique is not specific to moisture and the loss of any volatile components, such as terpenes, will be incorrectly classified as moisture. Karl Fischer (KF) titration is the only chemically specific test for moisture. This poster describes the instrument used to determine moisture content by Karl Fischer titration and compares the results of this data to loss on drying.
- 8.000.6109USP Modernization Initiative: Iodide Assay by Ion Chromatography
Potassium iodide (KI) is used to treat overactive thyroid and to protect the thyroid gland from the effects of radiation from inhaled or swallowed radioactive iodine. Currently, in the USP Potassium Iodide Monograph, iodide identification is performed by wet chemistry and assay by manual titration, which has a history of reduced precision and accuracy. As part of USP’s global monograph modernization initiative, an alternative selective and sensitive method was developed and validated – ion chromatography (IC). The proposed IC method can also be used for the identification test as an alternative to wet chemistry.