Column Finder
6.1011.030
Metrosep RP 2 Guard/3.5The Metrosep RP 2 Guard/3.5 is a guard column for universal use. It reliably protects the analytical separation column against contaminations. It reliably protects the analytical separation column against contamination, removing the smallest particles, traces of iron oxide and bacteria. The Metrosep RP 2 Guard/3.5 helps to reduce costs; its filter disk can be replaced very easily.
6.1011.040
Metrosep RP 3 Guard HC/4.0The Metrosep RP 3 Guard HC/4.0 is a guard column for universal use. It reliably protects the analytical separation column against contamination, securely removing lipophilic organic contamination, the smallest particles, traces of iron oxide and bacteria. The guard column is based on a polymer material and thanks to its larger pack volume, has a significantly higher capacity that the Metrosep RP 2Guard/3.5. It can be used throughout the entire pH range.
6.1016.500
Metrosep Dual 4 Guard Column Kit/4.6Even if the Dual-4 columns based on monolithic silica gel are very durable, the use of the Dual 4 guard column is advised in order to further increase the safety of the analytical separation column. The Dual 4 guard column is a PEEK cartridge which is also filled with monolithic silica gel. This cartridge is easy to replace and is screwed directly onto the analytical column in an aluminum holder. The proven "On Column Guard System" is simple to use and also offers the advantage of minimal dead volume.
6.1016.510
Metrosep Dual 4 Guard Column Cartridge/4.6Set with three guard column cartridges
6.1020.500
Metrosep A Supp 10 Guard/4.0The Metrosep A Supp 10 Guard/4.0 reliably protects the Metrosep A Supp 10 analytical separation columns against contamination. Thanks to the "On Column Guard System", the guard column is very easy to handle. The guard column screws easily and directly onto the analytical column. No tools are required.
6.1020.510
Metrosep A Supp 10 S-Guard/4.0The Metrosep A Supp 10 S-Guard/4.0 reliably protects the Metrosep A Supp 10 analytical separation columns against contamination. The guard column is simply connected to the separation column using capillary connections. No tools are required.
6.1020.520
Metrosep A Supp 10 Guard HC/4.0The Metrosep A Supp 10 Guard HC/4.0 is the high-capacity version of the Metrosep A Supp 10 Guard/4.0.
6.1020.600
Metrosep A Supp 10 Guard/2.0The Metrosep A Supp 10 Guard/2.0 column reliably protects the A Supp 10 analytical microbore separation columns against contamination. Thanks to the "On Column Guard System", the guard column is very easy to handle. The guard column screws easily and directly onto the analytical column without tools
6.1031.500
Metrosep A Supp 16 Guard/4.0The Metrosep A Supp 16 Guard/4.0 reliably protects the Metrosep A Supp 16 analytical separation columns against contamination. Thanks to the "On Column Guard System", the guard column is very easy to handle. The guard column screws easily onto the analytical column. No tools are required.
6.1031.510
Metrosep A Supp 16 S-Guard/4.0The Metrosep A Supp 16 S-Guard/4.0 reliably protects the Metrosep A Supp 16 analytical separation columns against contamination. The guard column is connected to the separation column simply using capillary connections. No tools are required.
6.1031.600
Metrosep A Supp 16 Guard/2.0The Metrosep A Supp 16 Guard/2.0 reliably protects the Metrosep A Supp 16 analytical separation columns with 2 mm inner diameter against contamination. Thanks to the "On Column Guard System", the guard column is very easy to handle. The guard column screws easily onto the analytical column. No tools are required.
6.1031.610
Metrosep A Supp 16 S-Guard/2.0The Metrosep A Supp 16 S-Guard/2.0 reliably protects the Metrosep A Supp 16 analytical separation columns with 2 mm inner diameter against contamination. The guard column is connected to the separation column simply using capillary connections. No tools are required.
6.1050.500
Metrosep C 4 Guard/4.0The Metrosep C 4 Guard/4.0 contains the C-4 column material and is used to protect all Metrosep cation columns that have a substrate based on silica gel. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column. The economical price is an additional plus. The Metrosep C 4 Guard/4.0 also works based on the "On Column Guard System" and is screwed directly onto the separation column with virtually no dead volume.
6.1050.510
Metrosep C 4 S-Guard/4.0The Metrosep C 4 S-Guard/4.0 contains the C-4 column material and is used to protect all Metrosep cation columns that have a substrate based on silica gel. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column. The economical price is an additional plus.
6.1050.530
Metrosep C 4 S-Guard - 50/4.0The Metrosep C 4 S-Guard - 50/4.0 contains the C 4 column material and is used to protect all Metrosep cation columns that have a substrate based on silica gel. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column. In comparison with Standard C 4 guard columns, the Metrosep C 4 S-Guard - 50/4.0 has a greater capacity and therefore an even longer service life.
6.1050.600
Metrosep C 4 Guard/2.0The Metrosep C 4 Guard/2.0 contains the C-4 column material and is used to protect all Metrosep cation columns with 2 mm inner diameters which have a substrate based on silica gel. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column. The economical price is an additional plus. The Metrosep C 4 Guard/2.0 also works based on the "On Column Guard System" and is screwed directly onto the separation column with virtually no dead volume.
6.1050.610
Metrosep C 4 S-Guard/2.0The Metrosep C 4 Guard/2.0 contains the C-4 column material and is used to protect all Metrosep cation columns with 2 mm inner diameters which have a substrate based on silica gel. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column. The economical price is an additional plus.
6.1051.500
Metrosep C 6 Guard/4.0The Metrosep C 6 Guard/4.0 contains the C 6 column material and is used to protect against particles and contamination. This considerably lengthens the service life of the analytical separation column. The Metrosep C 6 Guard/4.0 works according to the "On Column Guard System" and is screwed directly onto the respective separation column with virtually no dead volume.
6.1051.510
Metrosep C 6 S-Guard/4.0The Metrosep C 6 S-Guard/4.0 contains the C 6 column material and is used to protect it against particles and contamination. This considerably lengthens the service life of the analytical separation column.
6.1052.500
Metrosep C Supp 1 Guard/4.0The Metrosep C Supp 1 Guard/4.0 contains the C-Supp-1 column material and is used to protect Metrosep C-Supp-1 cation columns. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column. The Metrosep C Supp 1 Guard/4.0 also works based on the "On Column Guard System" and is screwed directly onto the separation column with virtually no dead volume.
6.1090.500
Metrosep Carb 2 Guard/4.0The Metrosep Carb 2 Guard/4.0 effectively removes contamination, thus protecting the analytical separation column. The design of the guard column has been selected in such a way that its influence on the chromatographic separation can be ignored.
6.1090.510
Metrosep Carb 2 S-Guard/4.0The Metrosep Carb 2 S-Guard/4.0 effectively removes contaminations, thus protecting the analytical separation column. The design of the guard column has been selected in such a way that its influence on the chromatographic separation can be ignored.
6.01010.350
Metrosep Chel PCC 1 VHC/4.0Preconcentration column for polyvalent cations. Monovalent cations are removed by matrix elimination prior to injection.
6.1006.330
Metrosep A PCC 2/4.0For anion preconcentration. For the preconcentration of anions in smaller sample volumes. This anion preconcentration column has a low capacity and is made of PEEK.
6.1006.340
Metrosep A PCC 2 HC/4.0For anion preconcentration and matrix elimination. The enlargement of the packing bed increases the capacity of the two preconcentration columns completely made of PEEK. The high capacity is required primarily when matrix effects might cause an overloading of the preconcentration column or when samples with high ionic strength are to be analyzed.
6.1006.350
Metrosep A PCC 2 VHC/4.0For anion preconcentration and matrix elimination. The very high capacity is required primarily when matrix effects might cause an overloading of the preconcentration column or when samples with high ionic strength are to be analyzed.
6.1010.300
Metrosep C PCC 1/4.0For cation preconcentration
6.1010.310
Metrosep C PCC 1 HC/4.0For cation preconcentration and matrix elimination
6.1010.320
Metrosep C PCC 1 VHC/4.0Cation preconcentration column with very high capacity
6.1014.000
Metrosep A Trap 1 - 100/4.0High-capacity anion column, which is used to purify the eluent flow. Even chemicals of the highest quality level, e.g. "Ultrapur" or "puriss", can still contain minimal anion contaminations. These are reliably held back by the Metrosep A Trap 1 - 100/4.0.This column is primarily used with gradient applications.
6.1014.100
Metrosep RP Trap 1 - 50/4.0The Metrosep RP Trap 1 - 50/4.0 column is used to eliminate organic contaminants from the eluent. The Metrosep RP Trap 1 - 50/4.0 column helps avoid eluent-related interference at the baseline, especially with gradient systems. Its use is also recommended for the purification of the p-cyanophenol eluent of the Metrosep Dual 4 separation columns.
6.1014.150
Metrosep RP Trap 2 - 100/4.0The Metrosep RP Trap 2 - 100/4.0 column is used to eliminate organic contaminants from the eluent. The Metrosep RP Trap 2 - 100/4.0 column helps avoid eluent-related interference at the baseline, especially with gradient systems. It is based on a polymer material. This means the Metrosep RP Trap 2 - 100/4.0 can be used in both the acidic and alkali pH range.
6.1014.200
Metrosep I Trap 1 - 100/4.0The Metrosep I Trap 1 - 100/4.0 column is used to eliminate ionic, i.e. cationic and anionic, contaminants from aqueous solutions. Its use is especially recommended for the purification of the transfer water in combination with "MISP" or "Metrohm Inline Sample Preparation". Using the Metrosep I Trap 1 - 100/4.0 column can significantly reduce the influence of the transfer water on the system blank.
6.1015.000
Metrosep C Trap 1 - 100/4.0High-capacity cation column, which is used to purify the eluent flow. Even reagents of the highest quality level, e.g. "Ultrapur" or "puriss", can still contain minimal amounts of cation contamination. These are reliably held back by the Metrosep C Trap 1 - 100/4.0.
6.1015.100
Metrosep BP 1 Guard/2.0The Metrosep BP 1 Guard/2.0 is used to generate a sufficiently high working pressure in the flow path of post-column reagents. They are used in combination with a high-pressure pump for conveying the post-column reagent in the Professional Reactor.
6.1015.200
Metrosep BO3 Trap 1 - 100/4.0Trap column for the removal of borate contaminants from the eluent. The Metrosep BO3 Trap 1 - 100/4.0 is used mainly in carbohydrate analysis with hydroxide eluents.
6.1015.300
Metrosep CO3 Trap 1 - 100/4.0Trap column for the removal of carbonate traces in hydroxide eluents.
6.1011.120
Spare filters for RP Guard, 10 pcs.Do not use for 6.1011.030.
6.1011.130
Spare filter for RP 2 Guard/3.5, 10 pieces6.1012.000
IC-RP sample preparation cartridge, 50 piecesFor manual sample preparation in ion chromatography: removal of lipophilic components.
6.1012.010
IC-H sample preparation cartridge, 50 piecesFor manual sample preparation in ion chromatography: removal of sample cations
6.1012.020
IC-Ag sample preparation cartridge, 50 piecesFor manual sample preparation in ion chromatography: removal of halides.
6.1012.030
IC-OH sample preparation cartridge, 50 piecesFor manual sample preparation in ion chromatography: removal of anions
6.1012.040
IC-Na sample preparation cartridge, 0.5 mL, 50 piecesFor manual sample preparation in ion chromatography: replacement of sample cations with sodium.
6.1012.050
IC-C18 sample preparation cartridge, 0.5 mL, 50 piecesFor manual sample preparation in ion chromatography: removal of lipophilic components
6.1012.100
IC-RP sample preparation cartridge, 10 piecesFor manual sample preparation in ion chromatography: removal of lipophilic components
6.1012.110
IC-H sample preparation cartridge, 10 piecesFor manual sample preparation in ion chromatography: removal of cations
6.1012.120
IC-Ag sample preparation cartridge, 10 piecesFor manual sample preparation in ion chromatography: removal of halides.