Search
Market-leading solutions
Product families (70)Product configurations for any application
Product models (714)Tried-and-tested applications
Applications (2251)Trainings & webinars by experts
Events (8)Electrodes
Electrodes (509)Columns
Columns (155)Accessories
Accessories (2248)Software
Software (269)Manuals & brochures
Documents (2595)Other content
Items (107)Inspiring industry insights
Insights (180)Unmatched support & service
Support & service (110)On-demand webinars
Webinars (66)News
News (98)2.1001.0220
OMNIS Advanced Titrator with magnetic stirrerInnovative, modular potentiometric OMNIS Titrator for stand-alone operation or as the core of an OMNIS titration system for endpoint titration and equivalence point titration (monotonic/dynamic). Thanks to 3S Liquid Adapter technology, handling chemicals is more secure than ever before. The titrator can be freely configured with measuring modules and cylinder units and can have a rod stirrer added as needed. If required, the OMNIS Advanced Titrator can be equipped for parallel titration via a corresponding software function license. Control via PC or local network; Connection option for up to four additional titration or dosing modules for additional applications or auxiliary solutions; Connection option for one rod stirrer; Various cylinder sizes available: 5, 10, 20 or 50 mL; Liquid Adapter with 3S technology: Secure handling of chemicals, automatic transfer of the original reagent data from the manufacturerMeasuring modes and software options:; Endpoint titration: "Basic" function license; Endpoint and equivalence point titration (monotonic/dynamic): "Advanced" function license; Endpoint and equivalence point titration (monotonic/dynamic) with parallel titration: "Professional" function license;
2.1014.0010
Pick&Place moduleModule for installation in the module plate of the Pick&Place of the OMNIS Sample Robot. This workstation takes up the sample beaker for the analysis. Used sensors are cleaned or parked in the storage beaker of the Pick&Place module between analyses. If stirring is required during the analysis, then a separate rod stirrer must be used for this workstation.
2.850.9010
IC Conductivity DetectorCompact and intelligent high performance conductivity detector for intelligent IC instruments. Outstanding temperature stability, the complete signal processing within the protected detector block and the latest generation of DSP – Digital Signal Processing – guarantee the highest precision of the measurement. No change of measuring ranges (not even automatic ones) is required, due to the dynamic working range.
2.863.0010
863 Compact IC AutosamplerThe 863 Compact IC Autosampler is the ideal help for routine analysis. It enables automation of the full range of Metrohm IC instruments.
2.921.1520
NIRS XDS Transmission OptiProbe AnalyzerRobust measuring system for monitoring the reactions of liquids in the technical center and pilot plantsThe NIRS XDS Transmission OptiProbe Analyzer enables efficient determination of the composition of aqueous products, clear liquids, solvents, and viscous samples. The instrument is equally suitable for use in technical centers or for at-line applications when upscaling production processes. NIRS disposable glass vials are available for viscous samples, keeping cleaning costs to a minimum. The optional NIRS VialHeater enables analysis of samples at temperatures of up to 200 °C.
AUT.UVIR.KIT.S
Autolab spectrophotometer kit UV/VIS/NIRThe Autolab spectrophotometer kit UV/VIS/NIR consist of: UA spectrophotometer, light source, fiber cables and two type of DIO trigger cables
BWT-840000358
i-Raman Plus 785H Portable Raman SpectrometerThe i-Raman® Plus 785H is part of our award-winning series of i-Raman portable Raman spectrometers powered by our innovative intelligent spectrometer technology. Using a high-quantum-efficiency CCD array detector with TE cooling and high dynamic range, this portable Raman spectrometer delivers excellent performance with low noise, even at integration times of up to 30 minutes, making it possible to measure weak Raman signals. The i-Raman Plus 785H features the unique combination of wide spectral range and high resolution with configurations which allow measurements from 65 cm-1 to 2,800 cm-1. The system’s small footprint, lightweight design, and low power consumption ensure research-grade Raman analysis capabilities at any location. The i-Raman Plus is equipped with a fiber probe for easy sampling, and can be used with a cuvette holder, a video microscope, an XYZ positioning stage with a probe holder, as well as our proprietary BWIQ® multivariate analysis software and BWID® identification software. With the i-Raman Plus, you always have a high precision Raman solution for qualitative and quantitative analysis.
STAT300
µStat 300 BipotentiostatμStat 300 is a portable BiPotentiostat that can be applied for Voltammetric or Amperometric measurements and can be used with one- or two-working electrodes configuration. Li-ion Battery powered, it can be easily connected to a PC via USB and wireless.
2.1001.0320
OMNIS Professional Titrator with magnetic stirrerInnovative, modular potentiometric OMNIS Titrator for stand-alone operation or as the core of an OMNIS titration system for endpoint titration and equivalence point titration (monotonic/dynamic). Thanks to 3S Liquid Adapter technology, handling chemicals is more secure than ever before. The titrator can be freely configured with measuring modules and cylinder units and can have a rod stirrer added as needed. Including "Professional" function license for parallel titration with additional titration or dosing modules. Control via PC or local network; Connection option for up to four additional titration or dosing modules for additional applications or auxiliary solutions; Connection option for one rod stirrer; Various cylinder sizes available: 5, 10, 20 or 50 mL; Liquid Adapter with 3S technology: Secure handling of chemicals, automatic transfer of the original reagent data from the manufacturerMeasuring modes and software options:; Endpoint titration: "Basic" function license; Endpoint and equivalence point titration (monotonic/dynamic): "Advanced" function license; Endpoint and equivalence point titration (monotonic/dynamic) with parallel titration: "Professional" function license;
2.1014.0110
Pick&Place module with stirrerModule for installation in the module plate of the Pick&Place of the OMNIS Sample Robot. This workstation takes up the sample beaker for the analysis. The built-in magnetic stirrer makes it possible to analyze samples that were prepared externally on a magnetic agitator directly in the Sample Robot without having to remove the magnetic stirring bar beforehand. Used sensors are cleaned or parked in the storage beaker of the Pick&Place module between analyses.
- 8.000.60628.000.6062Water determination in various plastics
The presence of excessive water in plastics adversely affects the performance of polymeric goods which is why water determination is of crucial importance. This article describes the accurate and straightforward determination of the water content using the Karl Fischer Oven Method in ten different plastic types that are not amenable to direct Karl Fischer titration. The experiments revealed that besides the determination of the oven temperature, sample preparation is one of the most important steps of the analysis, especially in case of hygroscopic plastic samples.
- 8.000.60638.000.6063Post-column chemistry for improved optical absorption detection
UV/VIS detection is one of the most sensitive detection techniques in trace-level chromatography. Sometimes, however, spectrophotometric detection lacks sensitivity, selectivity or reproducibility and chemical derivatizations are required. By using Metrohm`s rugged and versatile flow-through reactor, single- or multi-step derivatizations can be done fully automatically, in either pre- or post-column mode at any temperature between 25…120 °C. The variable reactor geometry allows to adjust the reactor residence time of the reactants according to derivatization kinetics. The flexibility of the reactor is demonstrated by optimizing four widespread post-column techniques: the relatively slow ninhydrin reaction with amino acids and the fast derivatizations of silicate, bromate and chromate(VI).
- 8.000.60648.000.6064Microbore columns: a contribution to green chemistry
Available sample size, mass sensitivity, efficiency and the detector type are important criteria in the selection of separation column dimensions. Compared to conventional 4 mm i.d. columns, microbore columns excel, above all, by their low eluent consumption. Once an eluent is prepared, it can be used for a long time. Additionally, the lower flow rates of microbore columns facilitate the hyphenation to mass spectrometers due to the improved ionization efficiency in the ion source.With the same injected sample amount, a halved column diameter involves a lower eluent flow and results in an approximate four-fold sensitivity increase. In a converse conclusion, this means that with less sample amount, microbore columns achieve the same chromatographic sensitivity and resolution than normal bore columns. This makes them ideally suited for samples of limited availability.
- 8.000.60658.000.6065Automated ion chromatographic determinations over six orders of magnitude
Metrohm`s intelligent Preconcentration Technique with Matrix Elimination (MiPCT-ME) excels in its capacity to perform automatic ion chromatographic determinations over 6 orders of magnitude. Crucial requirements for this are the system`s intelligence and the exact measurement of the sample volume. While the intelligence allows to compare results and take decisions, the dosing device takes over the high-precision liquid handling of even single-digit microliter volumes to the preconcentration column. By using only one analytical setup and without additional rinsing, samples containing both ultratraces and high concentrations can be analyzed.As the other Metrohm Inline Techniques, the MiPCT-ME technique presented reduces the workload, ensures complete traceability, is free of carryover effects and significantly improves accuracy and reproducibility of the results.
- 8.000.60668.000.6066Determination of the total acid number (TAN) using thermometric titration
The thermometric titration method presented here permits a simple and direct determination of the total acid number (TAN) in petroleum products. It is an invaluable alternative to current manual and potentiometric methods. Thermometric titration uses a maintenance-free temperature sensor that does not require rehydration and is free of fouling and matrix effects. The procedure requires minimal sample preparation. Results agree closely with those from the potentiometric titrimetric procedure according to ASTM D664, but the thermometric titration method is far superior in terms of reproducibility and speed of analysis, with determinations being complete in approximately one minute.
- 8.000.60678.000.6067Fully automatic determination of sodium in food samples
The analysis described in this poster dicusses thermometric titration as a promising method for the straightforward sodium determination in foodstuffs. Thermometric sodium titration was tested for its applicability to various food matrices such as soups, gravy and several salty snacks. Enthalpy change can be monitored as a change in temperature of the solution using a sensitive digital thermometer. The sodium determination described here relies on the exothermic precipitation of elpasolite (NaK2AlF6). The titrant is a standard aluminum solution which contains an excess of potassium ions. The titration is performed directly on a suspension of the food sample and is completed in under two minutes. The method is robust, can be fully automated and due to the highly reproducible high-frequency homogenization, copes with a variety of challenging food matrices (ketchup, instant soups, pretzels, etc.). In addition to this application note, you can find more information on thermometric sodium determination in foods in our application video available on YouTube: https://youtu.be/lnCp9jBxoEs
- 8.000.60698.000.6069Determination of the oxidation stability of fat-containing solid foodstuffs
The Rancimat method is a widely accepted method for the determination of the oxidation stability of natural fats and oils. Its main application is quality control in oil mills and the oil processing industry. At elevated temperatures and under the exposure of air, fatty acids are oxidized. The reaction products are absorbed in ultrapure water that is continually monitored for conductivity. After an induction period with slow reaction, the formation of volatile carboxylic acids is accelerated. At that time the conductivity begins to increase rapidly. Instead of investing weeks or months, the sample can be oxidized within a few hours.The method can also be used to determine the oxidation stability of solid foodstuffs that contain natural fats or oils. Frequently, a direct determination without extraction of the fat is possible, if the fat content exceeds a minimum level. In these cases, a simple and reliable assessment of the quality of the produced foodstuff is possible.A number of fat-containing solid foodstuffs such as almonds, peanuts, peanut-flavored puffs, potato chips, muffins, butter cookies, French fries, and instant noodles were successfully tested with the Rancimat method. The experiments revealed that the comminution of the sample is one of the most important steps. The grinding procedure of the tested samples was kept as simple as possible to avoid the use of expensive milling instrumentation.
- 8.000.60718.000.6071Trace-level determination of anions in the primary circuit of a PWR-type nuclear power plant using ion chromatography after inline sample preparation
The poster presents the ion chromatographic determination of organic degradation products such as glycolate, formate and acetate besides the standard anions fluoride, chloride, nitrate and sulfate.
- 8.000.60728.000.6072Trace-level determination of cations in the secondary circuit of a PWR-type nuclear power plant using ion chromatography after inline sample preparation
The presented IC system with inline sample preparation allows the determination of traces of lithium and sodium (ppt) in the presence of ppm quantities of ammonium and ethanolamine.
- 8.000.60738.000.6073Determination of anions in concentrated nitric acid by ion chromatography: the influence of temperature on column selectivity
Determination of chloride and sulfate in the presence of high nitrate concentrations. Optimization of the chromatographic separation by variation of the temperature and eluent composition.
Voices from Analytica 2024
Various customers wanted to share their experience with Metrohm instruments at Analytica 2024. Hear how our instruments are used for various applications in different industries.
Flexible and reliable electrochemical recycling
ESy-Labs uses a Metrohm Autolab potentiostat to accurately compare potential electrode materials and gather more information about the reactions.
Company
Metrohm is one of the world’s most trusted manufacturers of high-precision instruments for chemical analysis. Learn more about the company, how to find us, events, and trainings.
Locations
Automated analysis of water
The Laboratory of the Swiss Canton of Zurich uses OMNIS and TitrIC from Metrohm for fast, reliable, and reproducible drinking water analyses.
Spectroelectrochemistry with one instrument
The University of Burgos partnered up with Metrohm to create the first integrated spectroelectrochemistry instrument on the market.
Stool analysis in under one minute
A university laboratory in France uses the near-infrared spectrometer DS2500 Solid Analyzer for fast, easy, and hygienic stool analysis.
Digitalization runs in the veins of Metrohm
Metrohm has always been committed to digitalization and has incorporated the latest digital technology into its instruments. Learn more about Lab 4.0, laboratory automation and robotics, Process analytics 4.0, and Metrohm Enterprise Services.
Customer voices
Hear what our customers have to say about their experience with Metrohm instruments.
Polymer ID verification in under two minutes
Hauff-Technik relies on the handheld Raman spectrometer MIRA XTR from Metrohm for fast and reliable ID verification of incoming polymer pellets.
6.6056.026
Upgrade to additional tiamo™ 2.X-3.X license (1 lic.)Upgrade of an additional license from tiamo™ 2.X multi to tiamo™ 3.X
6.6056.027
Upgrade to additional tiamo™ 2.X-3.X license (5 lic.)Upgrade of 5 additional licenses of tiamo™ 2.X multi to tiamo™ 3.X
6.6056.028
Upgrade to additional tiamo™ 2.X-3.X license (10 lic.)Upgrade of 10 additional licenses of tiamo™ 2.X multi to tiamo™ 3.X.
6.6056.031
tiamo™ 3.X multi: 1 additional licenseOptional license for tiamo™ multi. The licence code of tiamo™ multi is required for ordering!
6.6056.032
tiamo™ 3.X multi: 5 additional licensesOptional licenses for tiamo™ multi. The licence code of tiamo™ multi is required for ordering!
6.6056.033
tiamo™ 3.X multi: 10 additional licensesOptional licenses for tiamo™ multi. The licence code of tiamo™ multi is required for ordering!
6.6056.206
tiamo™ 2.X light upgrade full: 1 LicenseAdds the functions of tiamo™ full version to tiamo™ light.
6.6056.207
tiamo™ 2.X light upgrade multi: 3 LicensesAdds the functions of tiamo™ multi version to tiamo™ light.
6.6056.208
tiamo™ 2.X full upgrade multi: 3 LicensesAdds the functions of tiamo™ multi version to tiamo™ full.
6.6056.251
Tiamo 2.5 Light CD: 1 licensetiamo™ 2.5 Light computer program for controlling a titration system.Up to two Metrohm instruments (Titrino, Titrando, etc.) can be connected; balances and other generic (i.e. non-Metrohm) instruments can be included without limitation; Graphical method editor with numerous templates; Layout manager for individual monitor interface; Professional database with reevaluation; High-performance report generator; Data export as PDF file, CSV, SLK; No parallel titration; No data export in XML format for LIMS; Dialog languages: German, English, French, Italian, Spanish, Czech, Portuguese, Polish, Russian, Slovakian, Japanese, Chinese, Traditional Chinese;
W10
Thick Film Tungsten Electrode (Aux.:C; Ref.:Ag) / Individually packagedThick Film Tungsten Electrode (Aux.:C; Ref.:Ag) / Individually packaged
PW-AU10
Thick Film Gold Electrode (Aux.:C; Ref.:Ag) / Plastic SubstrateThick Film Gold Electrode (Aux.:C; Ref.:Ag) / Plastic Substrate
TLFCL110
Thin-Layer Flow-Cell Integrated Screen-Printed Carbon ElectrodeThin-Layer Flow-Cell Integrated Screen-Printed Carbon Electrode (Aux.: C; Ref.:Ag)
TLFCL110-CIR
Thin-Layer Flow-Cell Integrated Screen-Printed Circular Carbon ElectrodeThin-Layer Flow-Cell Integrated Screen-Printed Circular Carbon Electrode (Aux.:C; Ref.:Ag)
TLFCL110S
Thin-Layer Flow-Cell Integrated Screen-Printed Carbon Electrode 2X1 mmThin-Layer Flow-Cell Integrated Screen-Printed Carbon Electrode 2X1 mm (Aux.:C; Ref.:Ag)
TLFCL1110
Thin-Layer Flow-Cell Integrated Dual Screen-Printed Carbon ElectrodeThin-Layer Flow-Cell Integrated Dual Screen-Printed Carbon Electrode (Aux.:C; Ref.:Ag)
TLFCL210AT-CIR
Thin-Layer Flow-Cell Integrated Screen-Printed Circular Gold ElectrodeThin-Layer Flow-Cell Integrated Screen-Printed Circular Gold Electrode (Aux.:C; Ref.:Ag)
TLFCL2222AT
Thin-Layer Flow-Cell Integrated Dual Screen-Printed Gold ElectrodeThin-Layer Flow-Cell Integrated Dual Screen-Printed Gold Electrode (Aux.:Au; Ref.:Au)
TLFCL510-CIR
Thin-Layer Flow-Cell Integrated Screen-Printed Circular Platinum ElectrodeThin-Layer Flow-Cell Integrated Screen-Printed Circular Platinum Electrode
SPESMIX
Mix of different working electrode material Screen-Printed ElectrodesMix of different working electrode material Screen-Printed Electrodes 110, 220AT, 220BT and 550 (25 units/model). Recommended for testing purposes.
- Jul 12, 2021Nonaqueous acid-base titrations – Common mistakes and how to avoid them
- Jul 19, 2021Fast and fundamental: influences on reliable electrochemical measurements
- Aug 2, 2021Chemical analysis of sourdough: pH and total titratable acidity (TTA)
The history of sourdough and how to achieve the best quality sourdough.
- Aug 23, 2021Best practice for separation columns in ion chromatography (IC) – Part 1
- Sep 20, 2021Coffee: serving up chemistry in every cup
The origins of coffee and how to determine the key quality parameters.
- May 25, 2021NIR spectroscopy in the polymer industry: The ideal tool for QC and product screening – Part 2
Near-infrared spectroscopy for assessing the quality of polypropylene and polyethylene.
- May 17, 2021How much do pipes rust in a year?
Learn more about corrosion and electrochemistry taking pipeline corrosion as an example.
- Apr 20, 2020Moisture Analysis – Karl Fischer Titration, NIRS, or both?
Water content, moisture analysis, and moisture quantification with Karl Fischer titration and near-infrared spectroscopy.
- Apr 12, 2021Recognition of endpoints (EP)
Learn more about potentiometric and photometric endpoint recognition in titrations.
- Apr 29, 2020A History of Chemistry – Part 1
6.1006.540
Metrosep A Supp 5 S-Guard/4.0The Metrosep A Supp 5 S-Guard/4.0 reliably protects the Metrosep A Supp 5 and 7 IC anion columns against contaminations from the sample or eluent.
6.1006.600
Metrosep A Supp 5 Guard/2.0The Metrosep A Supp 5 Guard/2.0 reliably protects the 2 mm versions of the Metrosep A Supp 5 and Metrosep A Supp 7 IC anion columns against contamination from the sample or eluent.It contains the same separation material as the Metrosep A Supp 5, is also made of PEEK, and is screwed directly onto the respective separation column with virtually no dead volume ("On Column Guard System"). The guard column prolongs the service life of the analytical column, with practically no influence on its chromatographic separating efficiency. The economical price and simple handling make using the A Supp 5 Guard/2.0 highly recommended.
6.1006.610
Metrosep A Supp 5 S-Guard/2.0The Metrosep A Supp 5 S-Guard/2.0 reliably protects the 2 mm versions of the Metrosep A Supp 5 and Metrosep A Supp 7 IC anion columns against contamination from the sample or eluent.It contains the same separation material as the Metrosep A Supp 5, is also made of PEEK, and is connected directly onto the respective separation column via capillary connection. The guard column prolongs the service life of the analytical column, with practically no influence on its chromatographic separating efficiency. The economical price and simple handling make using the A Supp 5 S-Guard/2.0 highly recommended.
6.1007.110
Nucleosil 5SA 2 Guard cartridge/4.0For the protection of the Nucleosil 5SA - 125/4.0 analytic separation column. Requires the 6.2821.140 holder for connection to the analytic column.
6.1010.450
Metrosep C 3 Guard/4.0The Metrosep C 3 S-Guard/4.0 contains the C-3 column material and is used to protect Metrosep C-3 cation columns. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column. The Metrosep C 3 Guard/4.0 also works based on the "On Column Guard System" and is screwed directly onto the separation column with virtually no dead volume.
6.1010.460
Metrosep C 3 S-Guard/4.0The Metrosep C 3 S-Guard/4.0 contains the C-3 column material and is used to protect Metrosep C-3 cation columns. Particles and contamination are reliably retained, considerably prolonging the service life of the analytical separation column.
6.1011.030
Metrosep RP 2 Guard/3.5The Metrosep RP 2 Guard/3.5 is a guard column for universal use. It reliably protects the analytical separation column against contaminations. It reliably protects the analytical separation column against contamination, removing the smallest particles, traces of iron oxide and bacteria. The Metrosep RP 2 Guard/3.5 helps to reduce costs; its filter disk can be replaced very easily.
6.1011.040
Metrosep RP 3 Guard HC/4.0The Metrosep RP 3 Guard HC/4.0 is a guard column for universal use. It reliably protects the analytical separation column against contamination, securely removing lipophilic organic contamination, the smallest particles, traces of iron oxide and bacteria. The guard column is based on a polymer material and thanks to its larger pack volume, has a significantly higher capacity that the Metrosep RP 2Guard/3.5. It can be used throughout the entire pH range.
6.1016.500
Metrosep Dual 4 Guard Column Kit/4.6Even if the Dual-4 columns based on monolithic silica gel are very durable, the use of the Dual 4 guard column is advised in order to further increase the safety of the analytical separation column. The Dual 4 guard column is a PEEK cartridge which is also filled with monolithic silica gel. This cartridge is easy to replace and is screwed directly onto the analytical column in an aluminum holder. The proven "On Column Guard System" is simple to use and also offers the advantage of minimal dead volume.
6.1016.510
Metrosep Dual 4 Guard Column Cartridge/4.6Set with three guard column cartridges
CELL-PEEK
Cell for Screen-Printed Electrodes in PEEKCell in PEEK for batch analysis which allows optional stirring and it's recommended for deaerated samples and for standard additions mode. Suitable for working with all catalogue Screen-Printed Electrodes but recommended to be used with work in solution format SPEs.
MAGNET96X
Magnetic support for format 96X Screen-Printed ElectrodesMagnetic support for format 96X Screen-Printed Electrodes. Recommended to perform analysis with magnetic beads
NINW-STR
Streptavidin modified Nickel NanowiresStreptavidin-modified nickel nanowires are an excellent option for the immobilization of a large amount of biotinylated molecules being the perfect candidate to be use in magnet-based (bio)assays - Available in 200 μL.
RPROBE-VIS-UV
Reflection probe VIS-UVReflection probe VIS-UV designed to perform reflection experiments suitable to work with our Reflection Cell for our Screen-printed electrodes or with any conventional cell.
CLENS
Collimator LensCollimator lens suitable to work with our Transmission Cell for transparent Screen-printed electrodes or with any conventional cell.
MEMB
Membrane for Screen-Printed ElectrodesMembrane for Screen-Printed Electrodes. Useful to perform analysis with small volumes of solution or sample (7,5-15 µL), allowing a good covering of the 3 electrodes system
QDCORE-550
CdSe Core Quantum Dots 550 nmCore CdSe are produced via chemical synthesis at high temperature in organic solvent (chloroform).QDCORE-550: em = 550 nm; concentration= 21 ± 2μM; diameter Ø= 2.52 ± 0.03 nm - Available in 10 mL.
QDCORE-570
CdSe Core Quantum Dots 570 nmCore CdSe are produced via chemical synthesis at high temperature in organic solvent (chloroform) - QDCORE-570: em = 570 nm; concentration= 23 ± 2μM; diameter Ø= 3.02 ± 0.01 nm - Available in 10 mL.
TRANSPACK
Pack for transmission experiments with SPEsTransmission pack to perfrom reflection experiments with SPEs:Includes: 1 x TRANSCELL, 1 x CLENS, 1 x TFIBER, 1 x RPROBE and 1 x CAST
QDCORE-585
CdSe Core Quantum Dots 585 nmCore CdSe are produced via chemical synthesis at high temperature in organic solvent (chloroform). QDCORE-585: em = 585 nm; concentration= 24 ± 2μM; diameter Ø= 3.18 ± 0.05 nm - Available in 10 mL.
- Spectroscopy Courses...Spectroscopy Courses
- Quality Certificatio...Quality Certifications
- Software Center
Find information, downloads, patches, and language packages for our software products.
- MagIC Net
Find information on compatibility and download the MagIC Net ion chromatography software as well as language packs.
- Metrohm IC Driver 1.0 for Agilent ICP-MS MassHunter
The Metrohm IC Driver for ICP-MS MassHunter enables the integration of Metrohm IC instruments in the Agilent software ICP-MS MassHunter. Learn about the compatibility with Windows OP and find more information.
- Vision
Download the Vision software for spectroscopy method development and find information, certificates, and release notes.
- StabNet
Find information on compatibility and download the StabNet software for Rancimat and Thermomat stability measurement instruments as well as language packs.
- Audit trail viewer for 900 Touch Control and Ti-Touch devices
Audit trail viewer software from Metrohm for audit trail file management for 900 Touch Control and Ti-Touch devices.
- tiBase - Discontinued
- IC Net (no longer supported)
- Feb 3, 2020Karl Fischer titration: how to deal with tricky matrices & time wasting routines
- Oct 18, 2021Analysis of water samples and water constituents
Revised edition of monograph Analysis of water samples and water constituents with Metrohm instruments including methods, applications, and literature.
- Jan 5, 2022Quality control and optimization of coating processes using ion chromatography (IC)
Impurities can have detrimental effects for example on the electrical properties of integrated circuits and final products in the semiconductor industry. Ion chromatography (IC) is the ideal method for analyzing ionic impurities, even in the ng/L range.
- Jun 21, 2022Raman Concatenation: Reduced fluorescence and extended spectral range
Raman Concatenation involves sequentially collecting Raman spectra from two NIR lasers with one Raman spectrometer and one Raman probe. m-oem, the Metrohm OEM brand, is pleased to present this exciting new technique that enables fluorescence-free spectra of the fingerprint and stretching region with increased sensitivity and discrimination.
- Jul 12, 2022Live demo of µStat-i MultiX
Metrohm DropSens presents the μStat-i MultiX, a multichannel bipotentiostat, galvanostat, and impedance analyzer with MultiplEIS® technology. Join the live demo on July 19, 2022 to learn more about the features and benefits of this instrument.
- Aug 3, 2020Launch of NIRS DS2500 Polyol Analyzer
Near-infrared spectrometer for fast, simple, and robust routine analysis of polyols.
- Feb 10, 2020What's suppression in ion chromatography all about? Theoretical aspects and practical benefits explained.
- Jan 10, 2022Quality control and optimization of coating processes in chrome plating
- 8.000.53308.000.5330Brochure: Pulp and Paper Industry – Optimizing Chemical Recovery in Pulp Mills with online spectroscopy (NIR)
In a pulp mill, chemical recovery is a key process as it does not only allow the reuse of chemicals but also provides utilities (steam, power) throughout the pulping process. Optimizing this process can lead to significant cost reductions and product quality improvements. This can be realized by monitoring in real-time the composition of the white and green liquors. Near-Infrared spectroscopy (NIRS) guarantees process control in real-time and seamless integration to allindustrial environments.
English
Other languages
- 8.000.53318.000.5331Brochure: Industrial Process Analyzers – Multipurpose online, inline, and atline chemical analysis
The Metrohm Process Analyzers take the famous Metrohm laboratory solutions a step further. Fully automated, online, and customizable analyzers facilitate process monitoring across a wide array of industries. Drawing on our core competencies in titration, spectroscopy, ion chromatography, and electrochemistry, we leverage our applications knowledge to create reliable solutions for process analysis that optimize efficiency, decrease chemical consumption and create a safer work environment.
English
Other languages
- 8.000.53338.000.5333Multi-parameter analysis of polymers with near-infrared spectroscopy (NIRS) – Faster quality control along the production cycle of bulk material to final product
To this day, manufacturers of plastics and polymers rely for the most part on physical and wet chemical methods to monitor the quality of their product. Due to the time consuming nature of these methods and the infrastructure (laboratory) and costs (chemicals, consumables) involved, these methods can negatively impact the productivity of the polymer process. Metrohm offers NIR solutions for fast and reliable routine quality control of feedstock, intermediates, and final products in the polymer industry. Metrohm NIR solutions require no chemicals for analysis, can be directly applied in the quality control process by anyone. The reliable results of crucial chemical and physical properties are provided in a matter of seconds.
English
- 8.000.53348.000.53342026 Preventive Maintenance
Preventive Maintenance can be part of Metrohm maintenance agreement and puts the focus on what is important toyou – performance. Critical components become worn and contaminated over time which leads to component failureand inconsistent performance. Metrohm Process Analytics recommends having a Preventive Maintenance service at leastonce a year.
English
Other languages
- 8.000.53358.000.53352029 Preventive Maintenance
Preventive Maintenance can be part of Metrohm maintenance agreement and puts the focus on what is important to you – performance. Critical components become worn and contaminated over time which leads to component failure and inconsistent performance. Metrohm Process Analytics recommends having a Preventive Maintenance service at least once a year.
English
Other languages
- 8.000.53368.000.5336OMNIS meets CUBIS® II – Seamless integration of the laboratory balance from Sartorius
The CUBIS® II high-end laboratory balance from Sartorius has now become a fully integrated member of the OMNIS platform. Be it compliance with regulatory requirements, process design, or network integration – the integration of the CUBIS® II in OMNIS meets superior standards regarding performance and usability.
English
Other languages
- 8.000.53378.000.53372029 Aluminum Analyzer – From Metrohm Process Analytics
Aluminum is the most abundant metallic element of the Earth’s crust (8%) and is a very reactive base metal. It has low density, high electrical and thermal conductivities and high corrosion resistance. Because of these remarkable characteristics, the metal is commonly used as a construction material for buildings, aircraft, and automobiles. It is also used in the production of metal alloys for semiconductors and as a coagulant in potable water plants. The 2029 Aluminum process analyzer from Metrohm Process Analytics is the most straightforward and easy-to-use tool to measure Al online. This brochure shows you the benefits of our 2029 Aluminum Analyzer.
English
- 8.000.53398.000.53392035 Hardness Process Analyzer
Different industrial electrolysis processes, such chlorine production and water desalination, require the use of costly electrolysis membranes. Therefore, purification of the brine has become an unavoidable step to preserve the membranes and to use less electricity during electrolysis. The level of impurities such as hardness (calcium and magnesium) is reduced in two treatment steps. After the secondary treatment with an ion exchange resin, impurity concentrations in brine can be reduced by a factor of 1000.The 2035 Hardness Process Analyzer from Metrohm Process Analytics is the ideal solution to measure hardness content online in ultrapure brine.
English
- 8.000.53408.000.5340Metrohm Process Analytics – Solution provider for online, inline, and atline process analysis.
Process analyzers designed and manufactured by Metrohm Process Analytics are the preferred solution for process monitoring in a wide range of industries. Whatever your project requirements and budget, Metrohm Process Analytics has the right solution for you. We offer analytical systems for electrochemistry, ion chromatography, ion selective measurements, photometry, spectroscopy, and titration. The four primary ways to implement analysis techniques in process analysis are outlined in this brochure (online, inline, atline, and offline), and depending on which one you implement, you can receive several benefits in return.
English
Other languages
- 8.000.53428.000.5342Brochure: Eco KF Titrator
The Eco Titrator is an affordable solution for determination of the water content in matrices ranging from foodstuffs, chemicals, paints, inks and more.
English
Other languages