Search
Market-leading solutions
Product families (100)Product configurations for any application
Product models (716)Tried-and-tested applications
Applications (2254)Trainings & webinars by experts
Events (4)Electrodes
Electrodes (537)Columns
Columns (155)Accessories
Accessories (2311)Software
Software (269)Manuals & brochures
Documents (2635)Inspiring industry insights
Insights (181)News
News (60)Unmatched support & service
Support & service (80)On-demand webinars
Webinars (75)Other content
Items (104)MVA-22
884 Professional VA fully automated for VAAutomated analysis system for high-performance, flexible trace determinations with voltammetry and polarography with the Multi-Mode Electrode pro or the scTRACE Gold. Comprising 884 Professional VA for MME, 919 IC Autosampler plus for VA, two 800 Dosinos, 843 Pump Station, measuring head for rotating disk electrodes, and extensive accessories. For sample series of up to 28 samples.Determinations with rotating disc electrodes can also be performed with the MVA-22, e.g. determinations of organic additives in electroplating baths with "Cyclic Voltammetric Stripping" (CVS), "Cyclic Pulse Voltammetric Stripping" (CPVS), and chronopotentiometry (CP).The viva software is required for control, data acquisition, and evaluation. PC, electrode set, and viva license need to be ordered separately.
MVA-23
884 Professional VA fully automated for CVS and large sample seriesAutomated analysis system for the high-performance, flexible determination of organic additives in electroplating baths using CVS ("Cyclic Voltammetric Stripping"), CPVS ("Cyclic Pulse Voltammetric Stripping"), and chronopotentiometry (CP), or voltammetric heavy metal determinations with rotating disk electrodes. Comprising 884 Professional VA for CVS, 858 Professional Sample Processor, four 800 Dosinos, 843 Pump Station, measuring head for rotating disk electrodes. and extensive accessories. For sample series of up to 56 samples.The MVA-23 can also be used to perform voltammetric determinations with the Multi-Mode Electrode or the scTRACE Gold.The viva software is required for control, data acquisition, and evaluation. PC, electrode set, and viva license need to be ordered separately.
MVA-24
884 Professional VA fully automated for CVS with Dosino for sample transferAutomated analysis system for the high-performance, flexible determination of organic additives in electroplating baths using CVS ("Cyclic Voltammetric Stripping"), CPVS ("Cyclic Pulse Voltammetric Stripping"), and CP ("Chronopotentiometry"). Comprising 884 Professional VA for CVS, 858 Professional Sample Processor with Dosino for sample transfer, 4x additional 800 Dosinos for auxiliary solutions, 843 Pump Station, measuring head for rotating disk electrodes, and extensive accessories. For sample series of up to 112 samples.The viva software is required for control, data collection, and evaluation. PC, electrode set, and viva license need to be ordered separately.
MVA-25
884 Professional VA fully automated for the determination of antioxidantsAutomated analysis system for the voltammetric determination of antioxidants in lubricants, including automatic sample preparation on the sample changer. Comprising 884 Professional VA, 858 Professional Sample Processor for antioxidants, 2x 800 Dosinos, 843 Pump Station, measuring head for rotating disk electrodes, and extensive accessories. For sample series of up to 24 samples.The viva software is required for control, data collection, and evaluation. PC, electrode set, and viva license need to be ordered separately.
ProfIC 1 - AnCat
"ProfIC 1 – AnCat" – Professional IC System for automated ion chromatographyThe very compact Professional IC system with conductivity detection enables the fully automatic determination of anions and cations. With "ProfIC 1 – AnCat", anions and cations can be determined not only in parallel but also in time-saving fashion completely independently of one another. Both of the systems integrated in "ProfIC 1 – AnCat" use the same 858 Professional Sample Processor with pump that is subjected to intelligent management by the MagIC Net™ software. Schematic diagram
ProfIC 1 - Anion
"ProfIC 1 – Anion" – Professional IC System for automated ion chromatographyThe Professional IC system with sequential suppression and conductivity detection enables the fully automatic determination of anions. "ProfIC 1" enables the safe management of all routine tasks in ion chromatography. It is simple to use and exceptionally reliable. Schematic diagram
ProfIC 1 - Cation
"ProfIC 1 – Cation" – Professional IC System for automated ion chromatographyProfessional IC system with conductivity detection enables the fully automatic determination of cations and anions (non-suppressed). "ProfIC 1" enables the safe management of all routine tasks in ion chromatography. It is simple to use and exceptionally reliable. Schematic diagram
ProfIC 2 - AnCat
"ProfIC 2 – AnCat" – Professional IC System with Inline UltrafiltrationThe very compact Professional IC system with Metrohm Inline Ultrafiltration and conductivity detection enables the fully automatic determination of anions and cations. With "ProfIC 2 – AnCat", anions and cations can be determined not only in parallel but also in time-saving fashion completely independently of one another. The two systems integrated in "ProfIC 2 – AnCat" use the same 858 Professional Sample Processor – Pump that is subjected to intelligent management by the MagIC Net™ software. Schematic diagram
ProfIC 2 - Anion
"ProfIC 2 – Anion" – Professional IC System with Inline UltrafiltrationThe Professional IC system with Metrohm Inline Ultrafiltration and conductivity detection enables the fully automatic determination of anions. "ProfIC 2" enables the safe management of all routine tasks in ion chromatography. It is simple to use and exceptionally reliable. Schematic diagram
ProfIC 2 - Cation
"ProfIC 2 – Cation" – Professional IC System with Inline UltrafiltrationThe Professional IC system with Metrohm Inline Ultrafiltration and conductivity detection enables the fully automatic determination of cations or anions (non-suppressed). "ProfIC 2" enables the safe management of all routine tasks in ion chromatography. It is simple to use and exceptionally reliable. Schematic diagram
- AN-H-033AN-H-033Determination of low levels of chloride in water
Determination of low levels of chloride (to approximately 5 mg/L Cl-) by thermometric titration.
- AN-H-034AN-H-034Determination of calcium and magnesium in process samples
Determination of calcium and magnesium in process solutions.
- AN-H-035AN-H-035Phosphate in fertilizers – Rapid and reliable determination by thermometric titration
Phosphorus is a primary macronutrient for plants and is a constituent of DNA and adenosine triphosphate (ATP), which is involved in many biological processes requiring energy. In fertilizers, phosphorus is present in the form of phosphate, as the most accessible form of phosphorus for plants is dihydrogen phosphate. Knowledge of the phosphorus content helps to select the right fertilizer for the plants.Traditionally, phosphate is determined gravimetrically (a time consuming procedure) or spectrophotometrically (expensive instrumentation). In this Application Note, an alternative method is presented, where phosphate is determined by a precipitation titration with magnesium. Various solid and liquid NPK fertilizers with phosphorus contents between 6.5 and 17% were analyzed. The analysis by thermometric titration requires no sample preparation in case of liquid NPK fertilizers and only minimal sample preparation in case of solid NPK fertilizers. One determination takes about 5 minutes.
- AN-H-036AN-H-036Determination of free fatty acids (FFA) in olive oil
Determination of free fatty acids (FFA) in oils.
- AN-H-037AN-H-037Determination of phosphate in an acid etching mixture
Determination of phosphate content in an acid etching bath.
- AN-H-038AN-H-038Determination of sulfate and total acids in a nitrating mixture
Determination of sulfate and total acids in a nitrating mixture.
- AN-H-039AN-H-039Determination of sodium lauryl ether sulfate
Determination of sodium lauryl ether sulfate surfactants.
- AN-H-040AN-H-040Determination of HCl (ppm range) in silicone oil
Determination of low content of HCl (around 10 ppm) in silicone oil.
- AN-H-041AN-H-041Standardization of cetyl pyridinium chloride solutions
Standardization of cetyl pyridinium chloride solutions for use as a cationic surfactant titrant in the determination ofanionic surfactants such as sodium lauryl ether sulfate.
- AN-H-042AN-H-042Standardization of thiosulfate titrant for copper determinations
This Application Note discusses the standardization of thiosulfate titrant for use in the determination of copper with thermometric titration.
6.1446.060
Stopper / B-14/15 / M106.1446.080
Threaded stopper / M86.1446.090
Stopper / B-14/15 / M86.1446.100
PTFE stopper for 12 mL UV quartz sample vesselFor 6.2414.000 quartz sample vessel
6.1446.110
Thermometer stopper for UV quartz sample tube 12 mLFor 6.2401.010 Thermometer
6.1446.120
Stopper / S96.1446.130
Stopper / B-14/156.1446.140
Stopper for 5 mL UV quartz sample vesselFor 6.2414.010 quartz sample vessel
6.1446.150
Thermometer stopper for UV quartz sample tube 5 mLFor 6.2401.010 Thermometer
6.1446.160
Thermometer stopper, B-14/15, oblique insertionTo have the inserts of the 6.1458.010 titration head in a sloping position.