Search
Market-leading solutions
Product families (100)Product configurations for any application
Product models (714)Tried-and-tested applications
Applications (2253)Trainings & webinars by experts
Events (3)Electrodes
Electrodes (537)Columns
Columns (155)Accessories
Accessories (2306)Software
Software (267)Manuals & brochures
Documents (2635)Inspiring industry insights
Insights (181)News
News (59)Unmatched support & service
Support & service (80)On-demand webinars
Webinars (75)Other content
Items (104)2.1009.0010
OMNIS Solvent ModuleOMNIS Solvent Module for reliable addition of solvent and aspirating off titration vessel content without contact with the reagents. Manual operation or control via OMNIS Software for maximum user-friendliness. Including accessories, solvent and waste bottle.
2.1010.0120
OMNIS Main Module S – WSMMain module for setting up an OMNIS Sample Robot WSM in size S. This module is equipped with the module and rack plate for up to 2 racks and an OMNIS Workstation Module. It is already equipped with the main lift and a gripper. It must be equipped with sample racks, gripper fingers, and an OMNIS Workstation Module for sample processing in order to use it to set up a functioning Sample Robot. The selection of these components proceeds in accordance with the application.
2.1010.1120
OMNIS Sample Robot S – WSM (1T/2P)OMNIS Sample Robot S – WSM, equipped with an OMNIS Workstation Module with 2 pumps for cleaning and extraction of the sensors and sample vessels, a workstation, rod stirrers, and extensive accessories for getting started directly with fully automated titration. The system provides space in two sample racks for 32 sample beakers of 120 mL each. This modular system is supplied completely installed and can thus be put into operation in a very short time. The system can also be extended upon request to include 2 additional peristaltic pumps and another workstation, thus doubling the throughput. If additional workstations are required, then the Sample Robot S can be extended to become an L-sized OMNIS Sample Robot, thus enabling samples from 7 racks to be processed in parallel on up to 4 workstations to quadruple the sample throughput.
2.1011.0120
OMNIS Main Module M – WSMMain module for setting up an OMNIS Sample Robot WSM in size M. This module is equipped with the module and rack plate for up to 5 racks and 4 workstations. It is already equipped with the main lift and a gripper. Sample racks, gripper fingers, and up to 2 OMNIS Workstation Modules for sample processing can also be attached in order to use it to set up a functioning Sample Robot. The selection of these components proceeds in accordance with the application.
2.1012.0120
OMNIS Main Module L – WSMMain module for setting up an OMNIS Sample Robot WSM in size L. This module is equipped with the module and rack plate for up to 7 racks and 4 workstations. It is already equipped with the main lift and a gripper. Sample racks, gripper fingers, and up to 2 OMNIS Workstation Modules for sample processing can also be attached in order to use it to set up a functioning Sample Robot. The selection of these components proceeds in accordance with the application.
2.1017.1000
OMNIS Oven Module 6 mLModule for installation in the module plate of the OMNIS Sample Robot Oven. This workstation picks up the 6 mL sample vial and transports it from the handover position into the oven and then back again after the analysis is completed.
2.1018.0010
OMNIS Coulometer without stirrerOMNIS Coulometer without magnetic stirrer for stand-alone operation or as the heart of an OMNIS titration system. The coulometer can be enhanced with additional titration, dosing or coulometer modules.Coulometry is the ideal method for water content determination in the trace range (10 μg to 10 mg absolute water content) in liquids, solids and gases. In addition, coulometric Karl Fischer titration is an absolute method making titer determination unnecessary.
2.1018.0020
OMNIS Coulometer with stirrerOMNIS Coulometer with magnetic stirrer for stand-alone operation or as the heart of an OMNIS titration system. The coulometer can be enhanced with additional titration, dosing or coulometer modules.Coulometry is the ideal method for water content determination in the trace range (10 μg to 10 mg absolute water content) in liquids, solids and gases. In addition, coulometric Karl Fischer titration is an absolute method making titer determination unnecessary.
2.1019.0010
OMNIS Coulometer Module without stirrerCoulometer module without magnetic stirrer for connection to an OMNIS Titrator or to an OMNIS Coulometer as enhancement to include a measuring interface.
2.1019.0110
OMNIS Coulometer Module with stirrerCoulometer module with magnetic stirrer for connection to an OMNIS Titrator or to an OMNIS Coulometer as enhancement to include a measuring interface.
- AB-018AB-018Simultaneous determination of gold and copper in electroplating baths and/or alloys by potentiometric titration
This Bulletin describes the simultaneous determination of gold and copper by potentiometric titration using an Fe(II) solution as titrant. Fe(II) reduces Au(III) directly to the free metal, whereas Cu(II) does not react. By the addition of fluoride ions the Fe(III) is complexed and a shift of the redox potential is effected. Afterwards, potassium iodide is added, thus reducing the Cu(II) to Cu(I), and the free iodine is again titrated with the Fe(II) solution using a Pt Titrode.Chemical reactions:Au(III) + 3 Fe(II) → Au + 3 Fe(III)2 Cu(II) + 2 I- → 2 Cu(I) + I2I2 + 2 Fe(II) → 2 I- + 2 Fe(III)
- AB-025AB-025Coatings on silver electrodes
Ag electrodes are used for the indication of the potentiometric endpoints in precipitation titrations between silver and halide or sulfide ions. A coating on the silver ring may increase the sensitivity of the electrode and can thus reduce the limit of detection. This is why a variety of coated Ag electrodes are commercially available. This bulletin describes how the silver ring of Ag electrodes can be coated with AgCl, AgBr, AgI or Ag2S by electrolysis.
- AB-027AB-027Potentiometric titration of chloride and bromide in the presence of each other
If chloride and bromide are present in approximately equal molar concentrations they can be titrated directly with silver nitrate solution after addition of barium acetate. If, however, the molar ratio n(Br-) : n(Cl-) changes from 1 : 1 to 1 : 5, 1 : 10, 5 : 1 or 10 : 1 then greater relative errors must be expected with this method. The Bulletin describes an additional titration method that allows bromide to be determined in the presence of a large excess of chloride. The determination of small chloride concentrations in the presence of a large excess of bromide is not possible by titration.
- AB-036AB-036Half wave potentials of metal ions for the determination by polarography
In the following tables, the half-wave potentials or peak potentials of 90 metal ions are listed. The half-wave potentials (listed in volts) are measured at the dropping mercury electrode (DME) at 25 °C unless indicated otherwise.
- AB-037AB-037Determination of chromium in iron and steel
Two methods are described for the determination of chromium: a biamperometric titration and a polarographic analysis.
- AB-039AB-039Potentiometric determination of nitrating acid
A potentiometric, nonaqueous method is described for analyzing nitrating acid using cyclohexylamine as titrant. Both sulfuric and nitric acid can be determined quantitatively.
- AB-040AB-040Determining the pH value of paper
Two electrometric methods for determining the pH value of papers with homogeneous and heterogeneous pH cross-sections are described.
- AB-042AB-042Determination of carbonyl compounds by potentiometric titration
Carbonyl compounds (CC) occur in many products, such as bio-oils and fuels, cyclic and acyclic solvents, flavors and mineral oils. Carbonyl compounds can be responsible for the instability of these products during storage or processing. Especially pyrolysis bio-oils are known to cause issues during storage, handling and upgrading. This bulletin describes an aqueous and a non-aqueous analytical titration method for the determination of carbonyl compounds by potentiometric titration.
- AB-046AB-046Potentiometric determination of cyanide
The determination of cyanide is very important not only in electroplating baths and when decontaminating wastewater but, due to its high toxicity, also in water samples in general. Concentrations of 0.05 mg/L CN- can already be lethal for fish.This Bulletin describes the determination of cyanide in samples of different concentrations by potentiometric titration.Chemical reactions:2 CN- + Ag+ → [Ag(CN)2]-[Ag(CN)2]- + Ag+ → 2 AgCN
- AB-048AB-048Check of Silver, Platinum and Gold electrodes
It is essential to know before starting the sample analysis if the electrode is in a good state or not. A well workingelectrode will increase the quality of your results, as the accuracy and precision will be increased. Furthermore, tedious error tracking can be omitted and no sample is wasted due to a defect or old electrode. There exist several ways how to check metal electrodes, e.g., measurement of redox potentials, potentiometric titration or bivoltammetric titration. This bulletin describes the best methods for the various by Metrohm available metal electrodes.
6.6059.115
MagIC Net Professional 1.x Upgrade to Version 3.x CD: 1 licenseProgram upgrade from MagIC Net Professional 1.x to MagIC Net Professional 3.x
6.6059.119
MagIC Net Multi 1.x Upgrade to Version 3.x CD: 3 licensesProgram upgrade from MagIC NetMulti 1.x to MagIC Net Multi 3.x.
6.6059.206
MagIC Net 2.x and 3.x Compact Upgrade to Professional: 1 licenseProgram upgrade from MagIC Net Compact to MagIC Net Professional
6.6059.207
MagIC Net 2.x and 3.x Compact Upgrade to Multi: 3 licensesProgram upgrade from MagIC Net Compact to MagIC Net Multi
6.6059.208
MagIC Net 2.x and 3.x Professional Upgrade to Multi: 3 licensesProgram upgrade from MagIC Net Professional to MagIC Net Multi
6.6059.331
MagIC Net 3.3 Compact CD: 1 licenseProfessional PC program for controlling one intelligent Compact IC instrument, one detector and one Autosampler, or one 771 Compact Interface. The software permits checks, data acquisition, data evaluation and data monitoring as well as report generation of ion chromatographic analyses.Graphical user interface for routine operations, extensive database programs, method development, configuration, and manual system control; very flexible user management, powerful database operations, extensive data export functions, individually configurable report generator, control and monitoring of all system components and the chromatography results.MagIC Net Compact complies fully with FDA Regulation 21 CFR Part 11 as well as GLP.MagIC Net is available in 16 dialog languages.1 license.
6.6059.332
MagIC Net 3.3 Professional CD: 1 licenseProfessional PC program for controlling all intelligent Professional IC systems, Compact IC instruments and their peripherals, such as various Autosamplers, 800 Dosino, 771 Compact Interface, etc. The software permits checks, data acquisition, data evaluation, data monitoring, and report generation of ion chromatographic analyses.Graphical user interface for routine operations, extensive database programs, method development, configuration and manual system control; very flexible user management, powerful database operations, extensive data export functions, individually configurable report generator, control and monitoring of all system components and the chromatography results.MagIC Net Professional complies fully with FDA Regulation 21 CFR Part 11 as well as GLP.MagIC Net is available in 16 dialog languages.1 license.
6.6059.333
MagIC Net 3.3 Multi CD: 3 licensesProfessional PC program for controlling all intelligent Professional IC systems, Compact IC instruments and their peripherals, such as various Autosamplers, 800 Dosino, 771 Compact Interface, etc. The software permits checks, data acquisition, data evaluation, data monitoring, and report generation of ion chromatographic analyses.Graphical user interface for routine operations, extensive database programs, method development, configuration, and manual control panel; very flexible user management, efficient database operations, extensive data export functions, individually configurable report generator, control and monitoring of all system components and the chromatography results.MagIC Net Multi complies fully with FDA Regulation 21 CFR Part 11 as well as with GLP.MagIC Net is available in 16 dialog languages.Client/server version with 3 licenses.
6.6059.393
MagIC Net 2.x/3.x Basic Update to MagIC Net 4.x Basic: 1 licenseUpdate from MagIC Net 2.x/3.x Basic to MagIC Net 4.x Basic.
6.6059.394
MagIC Net 2.x/3.x Compact Update to MagIC Net 4.x Compact: 1 licenseUpdate from MagIC Net 2.x/3.x Compact to MagIC Net 4.x Compact.
010
Screen-printed silver electrode (Aux.: C; Ref.: Ag)Screen-Printed Silver Electrode (Aux.:C; Ref.:Ag). Suitable for working with microvolumes, for decentralized assays or to develop specific sensors
2.854.0010
854 iConnectThe 854 iConnect – Electrode cable and measuring amplifier for intelligent "iTrodes" electrodes (cable length 150 cm).
3500003870
Blank (empty) working electrode 5mmEmpty working electrode for samples with a disk diameter of 5 mm.
3500003880
Copper working electrode 5 mmCopper working electrode with a disk diameter of 5 mm.
3500003900
Glassy Carbon working electrode 5mmGlassy Carbon working electrode with a disk diameter of 5 mm.For the 5 mm glassy carbon PTFE sleeve RDE electrode, please use item number 3500003890.
3500003910
Platinum working electrode 5 mm diskPlatinum working electrode with a disk diameter of 5 mm.
3500003930
Carbon steel working electrode 5 mmCarbon steel working electrode with a disk diameter of 5 mm.
6.00200.300
dUnitrode with Pt1000Digital, combined pH electrode for OMNIS with integrated Pt1000 temperature sensor. This electrode is particularly suitable for :- pH measurements and titrations in difficult, viscous, or alkaline samples- at elevated temperatures- long-term measurementsThe fixed ground-joint diaphragm is insensitive to contamination.Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.Alternatively: Reference electrolyte for measurements at T>80°C: Idrolyte, storage in Idrolyte.dTrodes can be used on OMNIS Titrators.
6.00201.300
dEcotrode PlusDigital, combined pH electrode for OMNIS.The electrode is suitable for aqueous acid/base titrations. The fixed ground-joint diaphragm is insensitive to contamination.Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.dTrodes can be used on OMNIS Titrators.
6.00202.300
dAquatrode Plus with Pt1000Digital, combined pH electrode for OMNIS, with integrated Pt1000 temperature sensor, for pH measurements/titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples. The fixed ground-joint diaphragm is insensitive to contamination. When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO3) = 1 mol/L (6.2310.010)). Storage in the bridge electrolyte used.dTrodes can be used on OMNIS Titrators.
- Jun 8, 2020Virus detection using screen-printed electrodes
- Apr 16, 2020What to consider when standardizing titrant
Blog about why titrant standardization is important and how to determine the titer.
- Feb 17, 2020Determining the total sulfite in food and beverages: faster and easier than ever
Fast and easy determination of total sulfite in food and beverages using ion chromatography.
- Jun 22, 2020Trace metal analysis with solid-state electrodes – Part 1
- Jul 13, 2020The role of process automation in an interconnected world – Part 2
- Oct 25, 2021Cyclic voltammetry (CV) – the essential analytical technique for catalyst research
- Nov 15, 2021NIR spectroscopy in the petrochemical and refinery industry: The ASTM compliant tool for QC and product screening – Part 3
- Dec 6, 2021Side reactions in Karl Fischer titration
How to recognize and avoid side reactions in Karl Fischer titration that falsify results.
- Jan 10, 2022USP <645> – simple automated analysis of ultrapure water
Blog post on automated analysis and quality control of ultrapure water used for injections and other medical and pharmaceutical applications.
- Jan 24, 2022NIR spectroscopy in the petrochemical and refinery industry: The ASTM compliant tool for QC and product screening – Part 5
Near-infrared spectroscopy and ASTM. Learn more about method development, method validation, and results validation.
6.1015.100
Metrosep BP 1 Guard/2.0The Metrosep BP 1 Guard/2.0 is used to generate a sufficiently high working pressure in the flow path of post-column reagents. They are used in combination with a high-pressure pump for conveying the post-column reagent in the Professional Reactor.
6.1015.200
Metrosep BO3 Trap 1 - 100/4.0Trap column for the removal of borate contaminants from the eluent. The Metrosep BO3 Trap 1 - 100/4.0 is used mainly in carbohydrate analysis with hydroxide eluents.
6.1015.300
Metrosep CO3 Trap 1 - 100/4.0Trap column for the removal of carbonate traces in hydroxide eluents.
6.1011.120
Spare filters for RP Guard, 10 pcs.Do not use for 6.1011.030.
6.1011.130
Spare filter for RP 2 Guard/3.5, 10 pieces6.1012.000
IC-RP sample preparation cartridge, 50 piecesFor manual sample preparation in ion chromatography: removal of lipophilic components.
6.1012.010
IC-H sample preparation cartridge, 50 piecesFor manual sample preparation in ion chromatography: removal of sample cations
6.1012.020
IC-Ag sample preparation cartridge, 50 piecesFor manual sample preparation in ion chromatography: removal of halides.
6.1012.030
IC-OH sample preparation cartridge, 50 piecesFor manual sample preparation in ion chromatography: removal of anions
6.1012.040
IC-Na sample preparation cartridge, 0.5 mL, 50 piecesFor manual sample preparation in ion chromatography: replacement of sample cations with sodium.
6.7304.010
FAST connector, straightFor connections with the quartz glass tubing
6.7301.160
Manual dosing syringe 100 µLManual dosing syringe for manual liquid sample injection
6.7303.200
50 µL syringe with replaceable needleReplacement syringe for MMS 5000 liquid setup
6.7303.210
100 µL syringe with replaceable needleReplacement syringe for MMS 5000 liquid setup
6.7303.220
Needles for 50 µL/100 µL syringes, 3 pcs.Replacement needle for syringe for MMS 5000 liquid setup
6.7301.230
Non-return tubing Combustion ICNon-return tubing for the protection of the gas box
6.7305.020
Septum perforated for PEEK gas inlet tubeSeptum perforated for transfer of the measuring gas via ABD lock.
6.7305.030
PEEK gas inlet tube for GSS/LPGFlexible tube made of PEEK guided through 6.730.5020 perforated septum.
6.7301.170
O-ring 14 × 4 mm for ABDSealing ring for connection between ABD and quartz glass tubing
6.7301.190
Sluice seal for ABDSeal for the sluice on the Automatic Boat Driver.