Market-leading solutions
Product families (69)Product configurations for any application
Product models (714)Tried-and-tested applications
Applications (2253)Trainings & webinars by experts
Events (3)Electrodes
Electrodes (537)Columns
Columns (155)Accessories
Accessories (2306)Software
Software (267)Manuals & brochures
Documents (2635)Other content
Items (118)Inspiring industry insights
Insights (183)News
News (61)On-demand webinars
Webinars (70)Unmatched support & service
Support & service (88)ZBADI20160
Titrolyzer ADI2016The ADI 2016 Titrolyzer performs potentiometric titrations by means of a high precision burette system and high performance electrodes. Different titration types include acid/base, redox and precipitation titrations. A self-finding inflection point technique can be applied for most applications. This can be performed either with fixed time interval additions or with drift controlled additions, depending on the application, accuracy and response desired.
ZBADI20162
Titrolyzer ADI2016 KF SS316The ADI 2016 Titrolyzer performs Volumetric Karl Fischer moisture/water determinations over a wide measurement range. Online closed loop sampling eliminates atmospheric moisture contamination when samples are taken manually and transported to the laboratory. Each step in analyzing the water content remains fixed and the same resulting in high repeatability. The analyzer is suitable for low ppm to percentage ranges of water content and equipped with all the features needed for 24/7 operation.
ZBADI20180
Ion-Analyzer ADI2018The ADI 2018 Ion-Analyzer performs a dynamic standard addition method by means of a high precision burette and high performance Ion Selective Electrodes (ISE). The method adapts the standard addition volume to the actual sample concentration by means of a dynamic differential approach. Moreover it takes into account ISE slope values over several ranges. This means that ISEs can be used to their ultimate low or high measuring ranges. Finally an accompanying temperature measurement eliminates possible temperature effects on the analysis results.
ZBADI20190
Process Colorimeter ADI2019The ADI 2019 Process Colorimeter performs photometric absorption measurements in the visible light range. A high performance compact photometer module developed by Metrohm Applikon is used. It comprises a thermostated cuvette with 3 cm light path and LED technology. The color development stabilization is automatically detected by making use of differential absorbance measurements. The ADI 2019 directly implements your colorimetric laboratory method in a simple way with little bias in obtained results.
- AN-H-109AN-H-109Determination of sulfuric acid, hydrofluoric acid, and ammonium bifluoride in acid mixtures
Results from three separate single endpoint titrations are used to calculate the results. The mixture of H2SO4, HF, and NH4F/HF contains H+ from H2SO4, HF, and NH4F/HF, SO42- from H2SO4, and F- from HF and NH4F/HF. Analysis of total H+ («total acids») by NaOH titration, F- by titrating with Al(NO3)3 («total fluoride») and SO42- by titrating with BaCl2 provides the information required to determine the composition of the mixture.
- AN-H-110AN-H-110Determination of sulfate in drinking water by barium chromate displacement
Sulfate is precipitated by reaction with an acidified barium chromate solution. The excess barium chromate is precipitated by basification with ammonia solution. Residual soluble chromate equivalent to the sulfate content of the sample is titrated with a solution of standard ferrous ion to a thermometrically determined endpoint.
- AN-H-111AN-H-111Determination of sulfate in harvested salt
Sulfate is precipitated as barium sulfate by reaction with an acidified barium chromate solution. The excess barium chromate is precipitated by basification with ammonia solution. Residual soluble chromate, equivalent to the sulfate content of the sample, is titrated with a solution of standard ferrous ion to a thermometrically determined endpoint.
- AN-H-112AN-H-112Determination of total sodium in commercial cheeses by thermometric titration
Samples of shredded, grated, or sliced cheese are dispersed with a high-speed disintegrator in a solution of trichloroacetic acid, which denatures protein and assists in the liberation of all sodium from the matrix. Toluene is added in a second step of the dispersion process to assist in the solubilization of fat. Ammonium fluoride solution is then added, and the sodium titrated with a titrant comprising 0.5 mol/L Al(NO3)3 and 1.1 mol/L KNO3 to an exothermic endpoint.Na+ + 2K+ + Al3+ + 6F- ↔ NaK2AlF6 ↓In this determination, ammonium fluoride (NH4F) has been found to give sharper endpoints than ammonium bifluoride (NH4F ∙HF). In addition to this application note, you can find more information on thermometric sodium determination in foods in our application video available on YouTube:https://youtu.be/lnCp9jBxoEs
- AN-H-114AN-H-114Determination of sulfuric acid, nitric acid, and hydrofluoric acid in etch solutions
Two separate titration sequences are required to analyze the mixture:- titration of the HF content with Al(NO3)3 (the «elpasolite» reaction)- titration of the H2SO4 with BaCl2 followed by titration with NaOH to determine the «total acids» contentThe HF, H2SO4, and «total acids» contents are converted to a HNO3 equivalent, with the HNO3 content found by subtracting the HF and H2SO4 from the «total acids» content.
- AN-H-115AN-H-115Determination of hydrofluoric acid, ammonium fluoride, and maleic acid in acid cleaning solutions
A direct thermometric titration (TET) with 2 mol/L NaOH is used to determine the HF, NH4F, and maleic acid (C4H4O4) contents of acid cleaning solutions. Three endpoints (EPs) are obtained, which may be assigned as follows:EP1: C4H4O4 (pKa1 = 1.9), HF (pKa = 3.17)EP2: C4H4O4 (pKa2 = 6.07)EP2: NH4F (pKa = 8.2)The HF content is determined by subtracting the difference (EP2-EP1) from EP1.
- AN-H-116AN-H-116Determination of sulfate in phosphoric acid through the standard addition of sulfuric acid
This Application Note supplements AN-H-003 with the treatment of the standard addition of sulfate as sulfuric acid. This technique may be contemplated when either sulfate levels are too low for a satisfactory direct titration, or when the sample matrix hinders endpoint detection, leading to poor precision and accuracy.
- AN-H-117AN-H-117Rapid determination of hydroxide and aluminum oxide in aluminate liquors
This Application Note describes the determination of the free and total hydroxide and aluminum oxide content in Bayer process and other aluminate liquors. The method is not subject to interference by carbonate ions. An aliquot of sodium aluminate liquor is titrated with potassium hydrogen carbonate solution to yield the free hydroxide ion content of the liquor.
- AN-H-118AN-H-118Determination of hydrochloric acid in acidic solutions containing iron and aluminum
The presence of the hydrated ion [Fe(H2O)6]3+ can interfere with the determination of «free acid» due to the low pKa value (~2.2) of this ion. Ions of metals such as Fe, Cu, and Al can be masked effectively with fluoride, and permit the determination of the acid content by thermometric alkalimetric titration with good accuracy and precision.
- AN-H-119AN-H-119Determination of ferric ion in acidic solutions
This Application Note deals with the determination of ferric ion in acidic and copper-free solutions using thermometric titration. The ferric ion is reduced by iodide. The released iodine reacts exothermically when titrated with thiosulfate solution. The endpoint is determined through temperature plotting by the temperature sensor Thermoprobe.
6.1518.253
Glass cylinder 50 mL / amber glassWith 6.1811.000 screw connector for 6.1805.XXX tubing with M6 thread
6.1537.010
Buret tip / tubing length 0.4 m6.1541.010
Buret tip, tubing length 0.4 mWith antidiffusion valve.
6.1542.010
Flat stopcock / ceramic6.1542.020
Flat stopcock / PCTFE/PTFE6.1543.040
Micro tip M6 threadForming a complete 6.1539.000 micro-burette tip together with 6.1805.160 capillary tubing and 6.1446.030 ball stopper
6.1543.060
Tip / M6 threadTip with M6 thread. Together with the 6.1805.160 capillary and the 6.1446.030 link stopper, it makes up the entire 6.1537.010 buret tip.
6.1543.070
Aspiration tip / M6 threadFor the 661 Pump Unit
6.1543.080
Aspiration tip / M6 threadUsed with 676 Sample Changer
6.1543.100
Dosing tip / M6 threadUsed with 676 Sample Changer and 681 Pump Unit
- 8.850.80578.850.8057Manual for 850 Professional IC Detector 2.850.9010
English
Other languages
- 8.850.80588.850.8058Manual for 850 Professional IC, 2.850.1210 - Cation – LP Gradient
English
Other languages
- 8.850.80598.850.8059Manual for 850 Professional IC, 2.850.2250 - Anion – MSM-HC – LP Gradient
English
Other languages
- 8.850.80608.850.8060Manual for 850 Professional IC, 2.850.1220 - Cation – Gradient - Cation HP-Gradient
English
Other languages
- 8.850.80618.850.8061Manual for 850 Professional IC, 2.850.2260 - Anion – MSM-HC – Gradient
English
Other languages
- 8.850.80628.850.8062Manual for IC Amperometric Detector, 2.850.9110
English
Other languages
- 8.850.80658.850.8065Manual for 850 Professional IC Conductivity Detector MB 2.850.9020
English
Other languages
- 8.851.80048.851.8004Manual for 851 Titrando
English
Other languages
- 8.852.80038.852.8003Manual for 852 Titrando
English
Other languages
- 8.853.80018.853.8001Instructions for Use 853 CO2 Suppressor
English
Other languages