Applikationer
Applikationer (22)Tilbehør til nirs calibration reflection
Reservedele (4)- AB-358AB-358Analysis of residual moisture in a lyophilized pharmaceutical product by near-infrared spectroscopy (NIRS)
This Application Bulletin describes the method of near-infrared spectroscopy in diffuse reflection for the purpose of determining residual moisture in a lyophilized pharmaceutical product. Numerous sample vials containing freeze-dried pharmaceuticals were spiked with varying amounts of water for calibration purposes. The resulting differences in the absorption wavelengths of the OH-oscillation were correlated with the water content determined by Karl Fischer titration using the algorithm of multiple linear regression (MLR).
- AN-NIR-119Moisture content and rheology determination of fluorinated polyolefins using NIRS
Near-infrared spectroscopy streamlines ethylene tetrafluoroethylene production by offering rapid, chemical-free analysis of melt flow rate and moisture content.
- AN-NIR-106Quality control of non-nutritive sweeteners with NIR spectroscopy
Near-infrared spectroscopy (NIRS) allows the simultaneous determination of sweeteners such as Stevia and sucralose in blends in less than one minute without any chemicals or sample preparation.
- AN-NIR-063Content uniformity test of pharmaceutical solid dosage forms using NIR spectroscopy
Uniformity of dosage units must be tested for QC purposes in the pharma industry. NIRS gives results in seconds along with the quantification of APIs and excipients.
- AN-NIR-104Analysis of green coffee beans by near-infrared spectroscopy
Near-infrared spectroscopy (NIRS) is a fast, chemical-free analytical method for the simultaneous analysis of density, water activity, and moisture of green coffee beans.
- AN-NIR-099Quality Control of fermentation broths
Cell fermentation processes are a reliable production method for small molecules and protein-based active pharmaceutical ingredients (APIs). The fermentation process requires monitoring of many different parameters to ensure optimal production. These quality parameters include pH, bacterial content, potency, glucose, and concentration of reducing sugars. Traditional laboratory analysis takes a significant amount of time and requires different analytical techniques to monitor these different quality parameters. Near-infrared spectroscopy (NIRS) offers a faster and more cost-efficient alternative to traditional methods for the determination of critical parameters in fermentation broths at any stage of the fermentation process.
- AN-NIR-093Quality Control of fermentation processes
The production of biofuels from renewable feedstock has grown immensely in the past several years. Bioethanol is one of the most interesting alternatives for fossil fuels, since it can be produced from raw materials rich in sugars and starch. Ethanol fermentation is one of the oldest and most important fermentation processes used in the biotechnology industry. Although the process is well-known, there is a great potential for its improvement and a proportional reduction in production costs. Due to the seasonal variation of feedstock quality, ethanol producers to need to monitor the fermentation process to ensure the same quality product is achieved. Near-infrared spectroscopy (NIRS) offers rapid and reliable prediction of ethanol content, sugars, Brix, lactic acid, pH, and total solids at any stage of the fermentation process.
- AN-PAN-1050Inline moisture analysis in fluid bed dryers by near-infrared spectroscopy
In the pharmaceutical industry, the fluid bed granulator/dryer is an integral point in the manufacture of powdered materials. Residual moisture must be kept within certain specifications to avoid fracturing of particles or caking (stickiness) of the bulk material. Current methods are slow and cumbersome, which can lead to damaged or degraded product. The ability to monitor the residual moisture content inline after drying is possible with near-infrared spectroscopy (NIRS). The 2060 The NIR Analyzer offers fast, reagent-free, nondestructive analysis of residual moisture of powders with a fluid bed probe specifically designed for these applications.
- AN-NIR-101Quality control of dried cannabis
Typically, cannabis potency testing is performed by HPLC, but the drawback is that it requires chemicals and it is time-consuming. Near-infrared spectroscopy (NIRS) is a preferred method for quantification of THC, CBD and CBG in dried cannabis because it provides results in less than a minute and does not require any chemicals.
- AN-SEC-001Spectroelectrochemistry: an autovalidated analytical technique
Spectroelectrochemical experiments not only provide outstanding qualitative information about samples, but also offer other quantitative data that can be considered when performing analyses. A single set of experiments allows analysts to obtain two calibration curves: one with the electrochemical data and another with the spectroscopic information. The concentration of tested samples is calculated by using both curves, confirming the obtained results by two different routes. In this Application Note, comparison between electrochemical and spectroscopic determinations demonstrates that the two methods measure uric acid (UA) indistinctively, with close agreement of the calculated values with empirical data.
6.7410.000
NIRS XDS tray for reflection standardA reflection standard is required for the calibration of the monochromator with the sample module. A holder in which the standard is positioned is used to fasten the calibration standard in place. A reflection standard and its associated holder are required for:NIRS XDS MultiVial Analyzer (order number: 29211210); NIRS XDS MasterLab Analyzer (order number: 2.921.1310);
6.7450.000
NIRS reflection standard, set of 2Set of wavelength standard and 80% reflection standard for the calibration of an NIRS XDS MasterLab Analyzer, NIRS XDS RCA Analyzer, NIRS XDS MultiVial Analyzer, NIRS XDS SmartProbe Analyzer, NIRS XDS Interactance OptiProbe Analyzer and NIRS DS2500 Analyzer.
6.7450.010
NIRS reflection standard, set of 7Set comprised of six reflection standards and one wavelength standard for the calibration of an NIRS XDS MasterLab Analyzer, NIRS XDS RCA Analyzer, NIRS XDS MultiVial Analyzer, NIRS XDS SmartProbe Analyzer, NIRS XDS Interactance OptiProbe Analyzer and NIRS DS2500 Analyzer in regulated environments.
6.7450.030
Certified NIRS 99% reflection standard for laboratory sensorsCertified 99% reflection standard for calibration of an NIRS XDS SmartProbe Analyzer