Support & service (1)- AN-PAN-1055Monitoring quality parameters in standard cleaning baths
Rapid inline monitoring of the major SC1/SC2 bath constituents is possible with reagent-free near-infrared spectroscopy, e.g., the 2060 The NIR-R Analyzer.
- AN-PAN-1057Inline monitoring of fermentation processes
Many fermentation quality parameters can be monitored simultaneously directly in the tank with inline near-infrared spectroscopy, such as the 2060 The NIR Analyzer.
- AN-PAN-1060Inline process monitoring of moisture content in tetrahydrofuran
This Process Application Note presents a method to accurately monitor low levels of moisture in tetrahydrofuran (THF) in «real-time» safely, reliably, and optimally with a 2060 The NIR Analyzer from Metrohm Process Analytics. Due to the hazardous and hygroscopic nature of THF, a single explosion-proof inline process analyzer is the preferred solution for industries to reduce chemical treatment, improve product quality, and increase profits.
- AN-NIR-064Quality control of ammonium nitrate
Specialty chemicals have to fulfill multiple quality requirements. One of these quality parameters, which can be found in almost all certificates of analysis and specifications, is the moisture content. The standard method for the determination of moisture content is Karl Fischer titration.This method requires reproducible sample preparation, chemicals, and waste disposal. Alternatively, near-infrared spectroscopy (NIR) can be used for the determination of moisture content. With this technique, samples can be analyzed without any preparation and without using any chemicals.
- AN-NIR-054Quality Control of Shampoo
Determination of sodium laureth sulfate (SLES), cocamidopropyl betaine (CABP), cocamidopropylamine oxide (CAW), cocamide diethanolamine (DEA), and carbopol in shampoo is a cost- and time-intensive process due to the use of large volumes of chemicals per analysis. This application note demonstrates that the DS2500 Solid Analyzer operating in the visible and near-infrared spectral region (Vis-NIR) provides a cost-efficient and fast solution for a simultaneous determination these parameters in shampoo. With no sample preparation or chemicals needed, Vis-NIR spectroscopy allows for the complete analysis in less than a minute.
- AN-NIR-035Quality Control of Polyols
Toxic and corrosive chemicals such as p-toluenesulfonyl isocyanate (TSI) and tetrabutylammonium hydroxide are used for the Hydroxyl Number analysis of polyols by titration according to ASTM D4274-16. This application note demonstrates how the XDS RapidLiquid Analyzer operating in the visible and near-infrared spectral region (Vis-NIR) provides a cost-efficient and fast solution for the determination of the hydroxyl (OH) number of polyols. With no sample preparation or chemicals needed, Vis-NIR spectroscopy allows for the analysis of polyols in less than a minute.
- AN-NIR-060Quality Control of Polyamides
Functional group and viscosity analysis (ASTM D789) of polyamides can be a lengthy and challenging process due to the sample’s limited solubility. This application note demonstrates that the DS2500 Solid Analyzer operating in the visible and near-infrared spectral region (Vis-NIR) provides a cost-efficient and fast solution for a simultaneous determination of the intrinsic viscosity as well as the amine, carboxylic, and moisture content in polyamides. With no sample preparation or chemicals needed, Vis-NIR spectroscopy allows for the analysis of polyamides in less than a minute.
- AN-NIR-071Automated acid number determination in lubricants with near-infrared spectroscopy
Acid Number (AN) analysis of lubricants (ASTM D664) can be a lengthy and costly process due to usage of large amounts of chemicals and required cleaning steps of the analytical equipment between each measurement. This application note demonstrates that the XDS RapidLiquid Analyzer operating in the visible and near-infrared spectral region (Vis-NIR) provides a cost-efficient, fast alternative for the determination of the acid number of lubricants. With no sample preparation or chemicals needed, Vis-NIR spectroscopy allows for the analysis of AN in less than a minute.
- AN-NIR-081Quality Control of Polyethylene
Determination of the density of polyethylene (PE) (ASTM D792) is normally a challenging procedure due to reproducibility difficulties. Measurement via FT-IR can be problematic when larger sample sizes must be analyzed due to sample inhomogeneity. This application note demonstrates that the DS2500 Solid Analyzer operating in the visible and near-infrared spectral region (Vis-NIR) provides a reliable and fast solution for determination of the density of PE. With no sample preparation or chemicals needed, Vis-NIR spectroscopy allows the analysis of larger, inhomogeneous sample sizes of PE in less than a minute.
- AN-NIR-091Quality Control of Mixed Acetic, Hydrofluoric, and Nitric Acids
This application note discusses an alternative near-infrared (NIR) spectroscopy method that can reliably determine all parameters within a minute, even in complex acid mixtures.